Real-time breath gas analysis of CO and CO2 using an EC-QCL

被引:54
|
作者
Ghorbani, Ramin [1 ]
Schmidt, Florian M. [1 ]
机构
[1] Umea Univ, Dept Appl Phys & Elect, SE-90187 Umea, Sweden
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2017年 / 123卷 / 05期
基金
瑞典研究理事会;
关键词
BROAD-BAND SPECTROSCOPY; QUANTUM CASCADE LASERS; CARBON-MONOXIDE; H2O;
D O I
10.1007/s00340-017-6715-x
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Real-time breath gas analysis is a promising, non-invasive tool in medical diagnostics, and well-suited to investigate the physiology of carbon monoxide (CO), a potential biomarker for oxidative stress and respiratory diseases. A sensor for precise, breath-cycle resolved, simultaneous detection of exhaled CO (eCO) and carbon dioxide (eCO(2)) was developed based on a continuous wave, external-cavity quantum cascade laser (EC-QCL), a low-volume multi-pass cell and wavelength modulation spectroscopy. The system achieves a noise-equivalent (1s) sensitivity of 8.5 x 10(-8) cm(-1) Hz(-1/2) and (2s) detection limits of 9 +/- 2 ppbv and 650 +/- 7 ppmv at 0.14 s spectrum acquisition time for CO and CO2, respectively. Integration over 15 s yields a precision of 0.6 ppbv for CO. The fact that the eCO(2) expirograms measured by capnography and laser spectroscopy have essentially identical shape confirms true real-time detection. It is found that the individual eCO exhalation profiles from healthy non-smokers have a slightly different shape than the eCO(2) profiles and exhibit a clear dependence on exhalation flow rate and breath-holding time. Detection of indoor air CO and broadband breath profiling across the 93 cm(-1) mode-hop-free tuning range of the EC-QCL are also demonstrated.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Real-Time Assessment of CO2 Migration Direction during Geologic Storage
    Matilla, Cesar A.
    Oruganti, YagnaDeepika
    Bryant, Steven L.
    Srinivasan, Sanjay
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 2227 - 2234
  • [32] Optical sensor for real-time monitoring of CO2 laser welding process
    Ancona, A
    Spagnolo, V
    Lugarà, PM
    Ferrara, M
    APPLIED OPTICS, 2001, 40 (33) : 6019 - 6025
  • [33] Fast real time and quantitative gas analysis method for the investigation of the CO2 reduction reaction mechanism
    Mutschler, Robin
    Luo, Wen
    Moioli, Emanuele
    Zuttel, Andreas
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (11):
  • [34] Real-Time Product Switching Using a Twin Catalyst System for the Hydrogenation of Furfural in Supercritical CO2
    Stevens, James G.
    Bourne, Richard A.
    Twigg, Martyn V.
    Poliakoff, Martyn
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (47) : 8856 - 8859
  • [35] Optical cavity enhanced real-time absorption spectroscopy of CO2 using laser amplitude modulation
    Dong, Jiahao
    Lam, Timothy T. -Y.
    Gray, Malcolm B.
    Warrington, Richard B.
    Roberts, Edward H.
    Shaddock, Daniel A.
    McClelland, David E.
    Chow, Jong H.
    APPLIED PHYSICS LETTERS, 2014, 105 (05)
  • [36] Real-time AFM analysis of the impact of CO2 on solid-supported ionic liquid nanomembranes
    Li, Kai-Xuan
    Wang, Wei-Wei
    Ding, Yu
    Wang, Ting
    Sun, Lan
    Ji, Xiao-Yan
    Laaksonen, Aatto
    Mao, Bing-Wei
    Yan, Jia-Wei
    JOURNAL OF MEMBRANE SCIENCE, 2025, 713
  • [37] The Influence of CO2 in the Measurements of Mass Concentration of Alcohol in Exhaled Breath Using Dual IR & EC Technology
    Anghel, Mirela Adelaida
    Iacobescu, Fanel
    PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 805 - 809
  • [38] The relative performance of NDIR-based sensors in the near real-time analysis of CO2 in air
    Pandey, Sudhir Kumar
    Kim, Ki-Hyun
    SENSORS, 2007, 7 (09) : 1683 - 1696
  • [39] Detection of structural pulmonary changes with real-time high-fidelity analysis of expiratory CO2
    Sassmann, Teresa
    Pienn, Michael
    Kovacs, Gabor
    Douschan, Philipp
    Foris, Vasile
    John, Nikolaus
    Zeder, Katarina
    Zirlik, Andreas
    Olschewski, Horst
    WIENER KLINISCHE WOCHENSCHRIFT, 2022, 134 (19-20) : 731 - 732
  • [40] Recognition of early pulmonary structural changes with real-time high fidelity expiratory CO2 analysis
    Sassmann, T.
    Pienn, M.
    Kovacs, G.
    Douschan, P.
    Foris, V.
    John, N.
    Zeder, K.
    Zirlik, A.
    Olschewski, H.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60