Real-time breath gas analysis of CO and CO2 using an EC-QCL

被引:54
|
作者
Ghorbani, Ramin [1 ]
Schmidt, Florian M. [1 ]
机构
[1] Umea Univ, Dept Appl Phys & Elect, SE-90187 Umea, Sweden
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2017年 / 123卷 / 05期
基金
瑞典研究理事会;
关键词
BROAD-BAND SPECTROSCOPY; QUANTUM CASCADE LASERS; CARBON-MONOXIDE; H2O;
D O I
10.1007/s00340-017-6715-x
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Real-time breath gas analysis is a promising, non-invasive tool in medical diagnostics, and well-suited to investigate the physiology of carbon monoxide (CO), a potential biomarker for oxidative stress and respiratory diseases. A sensor for precise, breath-cycle resolved, simultaneous detection of exhaled CO (eCO) and carbon dioxide (eCO(2)) was developed based on a continuous wave, external-cavity quantum cascade laser (EC-QCL), a low-volume multi-pass cell and wavelength modulation spectroscopy. The system achieves a noise-equivalent (1s) sensitivity of 8.5 x 10(-8) cm(-1) Hz(-1/2) and (2s) detection limits of 9 +/- 2 ppbv and 650 +/- 7 ppmv at 0.14 s spectrum acquisition time for CO and CO2, respectively. Integration over 15 s yields a precision of 0.6 ppbv for CO. The fact that the eCO(2) expirograms measured by capnography and laser spectroscopy have essentially identical shape confirms true real-time detection. It is found that the individual eCO exhalation profiles from healthy non-smokers have a slightly different shape than the eCO(2) profiles and exhibit a clear dependence on exhalation flow rate and breath-holding time. Detection of indoor air CO and broadband breath profiling across the 93 cm(-1) mode-hop-free tuning range of the EC-QCL are also demonstrated.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Role of respiratory physiology on real-time breath-gas analysis
    Sukul, Pritam
    Trefz, Phillip
    Schubert, Jochen
    Miekisch, Wolfram
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [22] Real-time monitoring system for CO and CO2 of automobile exhaust based on FM-TDLAS
    Tong Yang
    Liao Tongqing
    Liu Geng
    Zuo Changyu
    Li Bin
    Huang Caineng
    ICOSM 2020: OPTOELECTRONIC SCIENCE AND MATERIALS, 2020, 11606
  • [23] Highly precise and real-time measurements of 13CO2/12CO2 isotopic ratio in breath using a 2 μm diode laser
    Sun Ming-Guo
    Ma Hong-Liang
    Liu Qiang
    Cao Zhen-Song
    Wang Gui-Shi
    Liu Kun
    Huang Yin-Bo
    Gao Xiao-Ming
    Rao Rui-Zhong
    ACTA PHYSICA SINICA, 2018, 67 (06)
  • [24] MASS-SPECTROMETRY FOR ANALYSIS OF (CO2)-CO-13 IN THE BREATH
    SUEHIRO, M
    IIO, M
    MORIKAWA, J
    BUNSEKI KAGAKU, 1982, 31 (08) : 450 - 453
  • [25] Analysis of transcritical CO2 vortex tube performance using a real gas thermodynamic model
    Mansour, Ahmed
    Lagrandeur, Junior
    Poncet, Sebastien
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 177
  • [26] Noninvasive determination of cardiac output using single breath CO2 analysis
    Arnold, JH
    Stenz, RI
    Thompson, JE
    Arnold, LW
    CRITICAL CARE MEDICINE, 1996, 24 (10) : 1701 - 1705
  • [27] Notable uncertainties in near real-time CO2 emission estimates in China
    Hu, Hanwen
    Geng, Guannan
    Xu, Ruochong
    Liu, Yang
    Shi, Qinren
    Xiao, Qingyang
    Liu, Xiaodong
    Zheng, Bo
    Zhang, Qiang
    He, Kebin
    NPJ CLIMATE AND ATMOSPHERIC SCIENCE, 2025, 8 (01):
  • [28] Harnessing the power of AI and IoT for real-time CO2 emission monitoring
    Fan, Kaizhe
    Li, Quanjun
    Le, Zhen
    Li, Qian
    Li, Jianfeng
    Yan, Ming
    HELIYON, 2024, 10 (17)
  • [29] Real-time CO2 Sensor for the Optimal Control of Electronic EGR System
    Kim, Gwang-jung
    Choi, Byungchul
    Choi, Inchul
    2013 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SENSORS AND APPLICATIONS, 2013, 9044
  • [30] Real-time data processing method for CO2 dispersion interferometer on EAST
    Zhang, Jiamin
    Yao, Yuan
    Liu, Yuyang
    Chu, Yuqi
    Ruan, Tianyi
    Zhang, Yao
    Liu, Haiqing
    Jie, Yinxian
    Ling, Bili
    PLASMA SCIENCE & TECHNOLOGY, 2024, 26 (08)