Real-time breath gas analysis of CO and CO2 using an EC-QCL

被引:57
作者
Ghorbani, Ramin [1 ]
Schmidt, Florian M. [1 ]
机构
[1] Umea Univ, Dept Appl Phys & Elect, SE-90187 Umea, Sweden
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2017年 / 123卷 / 05期
基金
瑞典研究理事会;
关键词
BROAD-BAND SPECTROSCOPY; QUANTUM CASCADE LASERS; CARBON-MONOXIDE; H2O;
D O I
10.1007/s00340-017-6715-x
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Real-time breath gas analysis is a promising, non-invasive tool in medical diagnostics, and well-suited to investigate the physiology of carbon monoxide (CO), a potential biomarker for oxidative stress and respiratory diseases. A sensor for precise, breath-cycle resolved, simultaneous detection of exhaled CO (eCO) and carbon dioxide (eCO(2)) was developed based on a continuous wave, external-cavity quantum cascade laser (EC-QCL), a low-volume multi-pass cell and wavelength modulation spectroscopy. The system achieves a noise-equivalent (1s) sensitivity of 8.5 x 10(-8) cm(-1) Hz(-1/2) and (2s) detection limits of 9 +/- 2 ppbv and 650 +/- 7 ppmv at 0.14 s spectrum acquisition time for CO and CO2, respectively. Integration over 15 s yields a precision of 0.6 ppbv for CO. The fact that the eCO(2) expirograms measured by capnography and laser spectroscopy have essentially identical shape confirms true real-time detection. It is found that the individual eCO exhalation profiles from healthy non-smokers have a slightly different shape than the eCO(2) profiles and exhibit a clear dependence on exhalation flow rate and breath-holding time. Detection of indoor air CO and broadband breath profiling across the 93 cm(-1) mode-hop-free tuning range of the EC-QCL are also demonstrated.
引用
收藏
页数:11
相关论文
共 38 条
[31]   A single-breath technique with variable flow rate to characterize nitric oxide exchange dynamics in the lungs [J].
Tsoukias, NM ;
Shin, HW ;
Wilson, AF ;
George, SC .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (01) :477-487
[32]   Sensitive trace gas detection with cavity enhanced absorption spectroscopy using a continuous wave external-cavity quantum cascade laser [J].
van Helden, J. H. ;
Lang, N. ;
Macherius, U. ;
Zimmermann, H. ;
Roepcke, J. .
APPLIED PHYSICS LETTERS, 2013, 103 (13)
[33]   Multispecies breath analysis faster than a single respiratory cycle by optical-feedback cavity-enhanced absorption spectroscopy [J].
Ventrillard-Courtillot, Irene ;
Gonthiez, Thierry ;
Clerici, Christine ;
Romanini, Daniel .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)
[34]   Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits [J].
Wang, Chuji ;
Sahay, Peeyush .
SENSORS, 2009, 9 (10) :8230-8262
[35]   Fast and non-approximate methodology for calculation of wavelength-modulated Voigt lineshape functions suitable for real-time curve fitting [J].
Westberg, Jonas ;
Wang, Junyang ;
Axner, Ove .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2012, 113 (16) :2049-2057
[36]   Breath Analysis with Broadly Tunable Quantum Cascade Lasers [J].
Woerle, Katharina ;
Seichter, Felicia ;
Wilk, Andreas ;
Armacost, Chris ;
Day, Tim ;
Godejohann, Matthias ;
Wachter, Ulrich ;
Vogt, Josef ;
Radermacher, Peter ;
Mizaikoff, Boris .
ANALYTICAL CHEMISTRY, 2013, 85 (05) :2697-2702
[37]   CW EC-QCL-based sensor for simultaneous detection of H2O, HDO, N2O and CH4 using multi-pass absorption spectroscopy [J].
Yu, Yajun ;
Sanchez, Nancy P. ;
Griffin, Robert J. ;
Tittel, Frank K. .
OPTICS EXPRESS, 2016, 24 (10) :10391-10401
[38]   Exhaled carbon monoxide is not elevated in patients with asthma or cystic fibrosis [J].
Zetterquist, W ;
Marteus, H ;
Johannesson, M ;
Nordvall, SL ;
Ihre, E ;
Lundberg, JON ;
Alving, K .
EUROPEAN RESPIRATORY JOURNAL, 2002, 20 (01) :92-99