Real-time breath gas analysis of CO and CO2 using an EC-QCL

被引:57
作者
Ghorbani, Ramin [1 ]
Schmidt, Florian M. [1 ]
机构
[1] Umea Univ, Dept Appl Phys & Elect, SE-90187 Umea, Sweden
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2017年 / 123卷 / 05期
基金
瑞典研究理事会;
关键词
BROAD-BAND SPECTROSCOPY; QUANTUM CASCADE LASERS; CARBON-MONOXIDE; H2O;
D O I
10.1007/s00340-017-6715-x
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Real-time breath gas analysis is a promising, non-invasive tool in medical diagnostics, and well-suited to investigate the physiology of carbon monoxide (CO), a potential biomarker for oxidative stress and respiratory diseases. A sensor for precise, breath-cycle resolved, simultaneous detection of exhaled CO (eCO) and carbon dioxide (eCO(2)) was developed based on a continuous wave, external-cavity quantum cascade laser (EC-QCL), a low-volume multi-pass cell and wavelength modulation spectroscopy. The system achieves a noise-equivalent (1s) sensitivity of 8.5 x 10(-8) cm(-1) Hz(-1/2) and (2s) detection limits of 9 +/- 2 ppbv and 650 +/- 7 ppmv at 0.14 s spectrum acquisition time for CO and CO2, respectively. Integration over 15 s yields a precision of 0.6 ppbv for CO. The fact that the eCO(2) expirograms measured by capnography and laser spectroscopy have essentially identical shape confirms true real-time detection. It is found that the individual eCO exhalation profiles from healthy non-smokers have a slightly different shape than the eCO(2) profiles and exhibit a clear dependence on exhalation flow rate and breath-holding time. Detection of indoor air CO and broadband breath profiling across the 93 cm(-1) mode-hop-free tuning range of the EC-QCL are also demonstrated.
引用
收藏
页数:11
相关论文
共 38 条
[11]   Ultra-sensitive carbon monoxide detection by using EC-QCL based quartz-enhanced photoacoustic spectroscopy [J].
Dong, L. ;
Lewicki, R. ;
Liu, K. ;
Buerki, P. R. ;
Weida, M. J. ;
Tittel, F. K. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 107 (02) :275-283
[12]   Infrared laser spectroscopy for online recording of exhaled carbon monoxide-a progress report [J].
Fritsch, Thomas ;
Hering, Peter ;
Muertz, Manfred .
JOURNAL OF BREATH RESEARCH, 2007, 1 (01)
[13]   Direct and wavelength modulation spectroscopy using a cw external cavity quantum cascade laser [J].
Hancock, G. ;
van Helden, J. H. ;
Peverall, R. ;
Ritchie, G. A. D. ;
Walker, R. J. .
APPLIED PHYSICS LETTERS, 2009, 94 (20)
[14]   A mathematical model for breath gas analysis of volatile organic compounds with special emphasis on acetone [J].
King, Julian ;
Unterkofler, Karl ;
Teschl, Gerald ;
Teschl, Susanne ;
Koc, Helin ;
Hinterhuber, Hartmann ;
Amann, Anton .
JOURNAL OF MATHEMATICAL BIOLOGY, 2011, 63 (05) :959-999
[15]   Wavelength modulation absorption spectrometry -: an extensive scrutiny of the generation of signals [J].
Kluczynski, P ;
Gustafsson, J ;
Lindberg, ÅM ;
Axner, O .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (08) :1277-1354
[16]   Broadband spectroscopy with external cavity quantum cascade lasers beyond conventional absorption measurements [J].
Lambrecht, Armin ;
Pfeifer, Marcel ;
Konz, Werner ;
Herbst, Johannes ;
Axtmann, Felix .
ANALYST, 2014, 139 (09) :2070-2078
[17]   Versatile multipass cell for laser spectroscopic trace gas analysis [J].
Manninen, A. ;
Tuzson, B. ;
Looser, H. ;
Bonetti, Y. ;
Emmenegger, L. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 109 (03) :461-466
[18]   Acetylene in breath: background levels and real-time elimination kinetics after smoking [J].
Metsala, M. ;
Schmidt, F. M. ;
Skytta, M. ;
Vaittinen, O. ;
Halonen, L. .
JOURNAL OF BREATH RESEARCH, 2010, 4 (04)
[19]   From highly sophisticated analytical techniques to life-saving diagnostics: Technical developments in breath analysis [J].
Miekisch, Wolfram ;
Schubert, Jochen K. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :665-673
[20]   Endogenous carbon monoxide production in disease [J].
Owens, Elizabeth Oesterling .
CLINICAL BIOCHEMISTRY, 2010, 43 (15) :1183-1188