Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure

被引:7
作者
Chang, Hing-Chiu [1 ]
Chen, Nan-Kuei [2 ]
机构
[1] Univ Hong Kong, Dept Diagnost Radiol, Hong Kong, Hong Kong, Peoples R China
[2] Duke Univ, Med Ctr, Brain Imaging & Anal Ctr, BOX 3918, Durham, NC 27710 USA
关键词
Diffusion-weighted imaging; Interleaved echo-planar imaging; Multiplexed sensitivity encoding; Nyquist ghost correction; Two dimension phase correction; INHERENT CORRECTION; PARTIAL-FOURIER; MULTISHOT EPI; PROPELLER EPI; RESOLUTION; ECHO; MRI; RECONSTRUCTION; ERRORS; MUSE;
D O I
10.1016/j.mri.2016.04.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist artifact, which is usually reduced with 1D phase correction in post-processing. When there exist eddy current cross terms (e.g., in oblique-plane EPI), 2D phase correction is needed to effectively reduce Nyquist artifact. Second, minuscule motion induced phase inconsistencies in interleaved DWI scans result in image-domain aliasing artifact, which can be removed with reconstruction procedures that take shot-to-shot phase variations into consideration. In existing interleaved DWI reconstruction procedures, Nyquist artifact and minuscule motion-induced aliasing artifact are typically removed subsequently in two stages. Although the two-stage phase correction generally performs well for non-oblique plane EPI data obtained from well-calibrated system, the residual artifacts may still be pronounced in oblique-plane EPI data or when there exist eddy current cross terms. To address this challenge, here we report a new composite 2D phase correction procedure, which effective removes Nyquist artifact and minuscule motion induced aliasing artifact jointly in a single step. Our experimental results demonstrate that the new 2D phase correction method can much more effectively reduce artifacts in interleaved EPI based DWI data as compared with the existing two-stage artifact correction procedures. The new method robustly enables high-resolution DWI, and should prove highly valuable for clinical uses and research studies of DWI. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:974 / 979
页数:6
相关论文
共 44 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]  
Atkinson D, 2000, MAGN RESON MED, V44, P101, DOI 10.1002/1522-2594(200007)44:1<101::AID-MRM15>3.0.CO
[3]  
2-S
[4]   Nonlinear phase correction of navigated multi-coil diffusion images [J].
Atkinson, David ;
Counsell, Serena ;
Hajnal, Joseph V. ;
Batchelor, Philip G. ;
Hill, Derek L. G. ;
Larkman, David J. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :1135-1139
[5]   Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system [J].
Bammer, P ;
Stollberger, R ;
Augustin, M ;
Simbrunner, J ;
Offenbacher, H ;
Kooijman, H ;
Ropele, S ;
Kapeller, P ;
Wach, P ;
Ebner, F ;
Fazekas, F .
RADIOLOGY, 1999, 211 (03) :799-806
[6]   Characterizing and Correcting Gradient Errors in Non-Cartesian Imaging: Are Gradient Errors Linear Time-Invariant (LTI)? [J].
Brodsky, Ethan K. ;
Samsonov, Alexey A. ;
Block, Walter F. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) :1466-1476
[7]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[8]   Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes [J].
Butts, K ;
deCrespigny, A ;
Pauly, JM ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :763-770
[9]   Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3 Tesla clinical MRI scanner [J].
Chang, Hing-Chiu ;
Sundman, Mark ;
Petit, Laurent ;
Guhaniyogi, Shayan ;
Chu, Mei-Lan ;
Petty, Christopher ;
Song, Allen W. ;
Chen, Nan-Kuei .
NEUROIMAGE, 2015, 118 :667-675
[10]   Interleaved Diffusion-Weighted EPI Improved by Adaptive Partial-Fourier and Multiband Multiplexed Sensitivity-Encoding Reconstruction [J].
Chang, Hing-Chiu ;
Guhaniyogi, Shayan ;
Chen, Nan-kuei .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) :1872-1884