Fabrication of Nano Flower-shaped Platinum on Glassy Carbon Electrode as a Sensitive Sensor for Lead Electrochemical Analysis

被引:14
作者
Thi Lieu Nguyen [1 ,2 ]
Van Hoang Cao [2 ]
Thi Hai Yen Pham [3 ]
Truong Giang Le [1 ,3 ]
机构
[1] Grad Univ Sci & Technol, Vietnam Acad Sci & Technol, 18 Hoang Quoc Viet, Cau Giay Hanoi, Vietnam
[2] Quy Nhon Univ, Dept Chem, 170 An Duong Vuong, Quy Nhon, Binh Dinh, Vietnam
[3] Vietnam Acad Sci & Technol, Inst Chem, 18 Hoang Quoc Viet, Hanoi, Vietnam
关键词
Platinum nanoflowers; Glassy carbon; Anodic stripping voltammetry; Lead determination; STRIPPING VOLTAMMETRIC DETERMINATION; PASTE ELECTRODE; HEAVY-METALS; NANOPARTICLES; IONS; WATER; FILM; PB; CONTAMINATION; DEPOSITION;
D O I
10.1002/elan.201900021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Platinum nanoflowers modified glassy carbon electrodes (PtNFs/GCE) was fabricated simply for lead determination in water samples. The modified electrodes were prepared by electrodeposition in hexachloroplatinic acid solution at constant potential. The influence of deposition time and potential on surface morphology, chemical composition, electrochemical properties of electrode were investigated. At -0.2 V of potential and 150 s of deposition duration, platinum developed as nanoflower shape and scattered densely all over the glassy carbon surface, producing the largest electrochemically active surface areas. The highest differential pulse stripping voltammetry (DPSV) signal of lead was obtained by using the prepared electrode. Under optimized experimental condition of electrolyte, accumulation potential and time, the peak current was found to be linear proportion to lead concentration in range of 1 to 100 mu g L-1 (slope=0.371) with a limit of detection of 0.398 mu g L-1. The method has good repeatability and reproducibility with relative standard deviations of 1.47 % and 4.83 %, respectively. The modified PtNFs/GCE also demonstrated an excellent long-term stability with only 9 % decrease in Pb peak current over 30 days. Moreover, the performance of the modified PtNFs/GCE in determination of Pb(II) in two industrial wastewaters was good agreement with data obtained by a graphite furnace atomic absorption spectrometry (GFAAS) method.
引用
收藏
页码:2538 / 2545
页数:8
相关论文
共 43 条
[1]   Simultaneous trace-levels determination of Hg(II) and Pb(II) ions in various samples using a modified carbon paste electrode based on multi-walled carbon nanotubes and a new synthesized Schiff base [J].
Afkhami, Abbas ;
Bagheri, Hasan ;
Khoshsafar, Hosein ;
Saber-Tehrani, Mohammad ;
Tabatabaee, Masoumeh ;
Shirzadmehr, All .
ANALYTICA CHIMICA ACTA, 2012, 746 :98-106
[2]  
[Anonymous], 1996, ELECT PHASE FORMATIO
[3]  
[Anonymous], 2008, Guidelines for Drinking-water Quality, Incorporating 1st and 2nd Addenda, Volume 1, Recommendations, V1
[4]  
Bard A. J., 2000, ELECTROCHEMICAL METH
[5]   Monodisperse Platinum Nanospheres with Adjustable Diameters from 10 to 100 nm: Synthesis and Distinct Optical Properties [J].
Bigall, Nadja C. ;
Haertling, Thomas ;
Klose, Markus ;
Simon, Paul ;
Eng, Lukas M. ;
Eychmueller, Alexander .
NANO LETTERS, 2008, 8 (12) :4588-4592
[6]   Graphene electrochemistry: fundamental concepts through to prominent applications [J].
Brownson, Dale A. C. ;
Kampouris, Dimitrios K. ;
Banks, Craig E. .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (21) :6944-6976
[7]   Simultaneous detection of ultratrace lead and copper with gold nanoparticles patterned on carbon nanotube thin film [J].
Bui, Minh-Phuong Ngoc ;
Li, Cheng Ai ;
Han, Kwi Nam ;
Pham, Xuan-Hung ;
Seong, Gi Hun .
ANALYST, 2012, 137 (08) :1888-1894
[8]   Simultaneous determination of lead(II) and cadmium(II) at a glassy carbon electrode modified with GO@Fe3O4@benzothiazole-2-carboxaldehyde using square wave anodic stripping voltammetry [J].
Dahaghin, Zohreh ;
Kilmartin, Paul A. ;
Mousavi, Hassan Zavvar .
JOURNAL OF MOLECULAR LIQUIDS, 2018, 249 :1125-1132
[9]   A voltammetric sensor based on glassy carbon electrode modified with 1H-1, 2,4-triazole-3-thiol coating for rapid determination of trace lead ions in acetate buffer solution [J].
Danyildiz, Zafer ;
Uzun, Demet ;
Tabanligil Calam, Tugba ;
Hasdemir, Erdogan .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 805 :177-183
[10]   Differential pulse anodic stripping voltammetric determination of Pb ion at a montmorillonites/polyaniline nanocomposite modified glassy carbon electrode [J].
Dong, YongPing ;
Ding, Yong ;
Zhou, Ying ;
Chen, Jun ;
Wang, ChengMing .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 :206-212