Optical coherence tomography findings: insights from the "randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions" (PRISON IV) trial

被引:0
作者
Teenwen, Koen [1 ]
Spoormans, Eva M. [1 ]
Bennett, Johan [2 ]
Dubois, Christophe [2 ]
Desmet, Walter [2 ]
Ughi, Giovanni J. [2 ]
Belmans, Ann
Kelder, Johannes C. [1 ]
Tijssen, Jan G. P.
Agostoni, Pierfrancesco [1 ]
Suttorp, Marrten J. [1 ]
Adriaenssens, Tom [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
[2] St Vincent Hosp, Dept Cardiac Med, Leuven, Belgium
关键词
chronic coronary total occlusion; drug-eluting stent; optical coherence tomography; stable angina; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; REGISTRY; CTO; MECHANISMS; COVERAGE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85%) patients underwent repeat angiography. Of these, 60 consecutive patients received optical coherence tomography divided over both stent groups. The mean number of struts analysed was 750 +/- 337 and 633 +/- 358 in SES and EES patients, respectively (p=0.07). The minimal lumen area, minimal stent area, maximal neointima area and neointimal thickness were comparable between the groups (4.8 +/- 2.1 and 4.4 +/- 1.5 mm2;5.3 +/- 1.8 and 5.3 +/- 1.4 mm2; 2.5 +/- 2.0 and 2.2 +/- 1.5 mm2; 0.7 +/- 1.7 and 0.4 +/- 0.2 mm). The percentage of uncovered struts was higher with EES (6.2 +/- 7.5% and 11.9 +/- 13.4%, p=0.04), whereas the percentage of malapposed struts and mean number of coronary evaginations were significantly higher with SES (2.9 +/- 4.0% and 1.2 +/- 2.4%, p=0.02; 18.5 +/- 17.7 and 5.3 +/- 3.1, p=0.004). Conclusions: The optical coherence tomography findings of this substudy demonstrated improved strut coverage with ultra-thin strut SES with bioresorbable polymer compared to thin-strut EES with durable polymer in CTO. On the other hand, SES showed a higher rate of stent strut malappositon and coronary evaginations. The clinical relevance of these findings remains to be demonstrated.
引用
收藏
页码:522 / 530
页数:9
相关论文
共 50 条
[31]   A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study [J].
Koen Teeuwen ;
Tom Adriaenssens ;
Ben JL Van den Branden ;
José PS Henriques ;
Rene J Van der Schaaf ;
Jacques J Koolen ;
Paul HMJ Vermeersch ;
Mike AR Bosschaert ;
Jan GP Tijssen ;
Maarten J Suttorp .
Trials, 13
[32]   Comparison of the Ultrathin Strut, Biodegradable Polymer Sirolimus-eluting Stent With a Durable Polymer Everolimus-eluting Stent in a Chinese Population: The Randomized BIOFLOW VI Trial [J].
Li, Chongjian ;
Yang, Yuejin ;
Han, Yaling ;
Song, Dan ;
Xu, Jing ;
Guan, Changdong ;
Gao, Runlin ;
Garcia-Garcia, Hector M. ;
Waksman, Ron ;
Xu, Bo .
CLINICAL THERAPEUTICS, 2020, 42 (04) :649-+
[33]   Which is Better, Biodegradable polymer Coated Biolimus A9-eluting Stents or Biocompatible Durable-polymer Coated Everolimus-eluting Stents?: Serial Optical Coherence Tomographic Evaluation [J].
Shutta, Ryu ;
Nishino, Masami ;
Yasumoto, Koji ;
Yasumura, Keisuke ;
Yorifuji, Hiroki ;
Masuyama, Kiyoshi ;
Nushiro, Yu ;
Kato, Taishi ;
Idemoto, Akiko ;
Tanaka, Akihiro ;
Okamoto, Naotaka ;
Mori, Naoki ;
Yoshimura, Takahiro ;
Makino, Nobuhiko ;
Egami, Yasuyuki ;
Tanouchi, Jun .
CIRCULATION, 2014, 130
[34]   Comparison of Endothelial Barrier Functional Recovery After Implantation of a Novel Biodegradable-Polymer Sirolimus-Eluting Stent in Comparison to Durable- and Biodegradable-Polymer Everolimus-Eluting Stents [J].
Sakamoto, Atsushi ;
Torii, Sho ;
Jinnouchi, Hiroyuki ;
Guo, Liang ;
Cornelissen, Anne ;
Kuntz, Salome ;
Cheng, Qi ;
Fernandez, Raquel ;
Paek, Ka Hyun ;
Harris, Kathryn ;
Srivastava, Mukta C. ;
Kolodgie, Frank D. ;
Virmani, Renu ;
Finn, Aloke, V .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 24 :1-10
[35]   Long-term coronary arterial response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents: Five-year follow-up optical coherence tomography study [J].
Kuramitsu, Shoichi ;
Sonoda, Shinjo ;
Yokoi, Hiroyoshi ;
Iwabuchi, Masashi ;
Nishizaki, Yuji ;
Shinozaki, Tomohiro ;
Domei, Takenori ;
Hyodo, Makoto ;
Inoue, Katsumi ;
Shirai, Shinichi ;
Ando, Kenji ;
Nobuyoshi, Masakiyo .
ATHEROSCLEROSIS, 2014, 237 (01) :23-29
[36]   Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with coronary artery disease: three-year follow-up of the COMPARE II (Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent) trial [J].
Vlachojannis, Georgios J. ;
Smits, Pieter C. ;
Hofma, Sjoerd H. ;
Togni, Mario ;
Vazquez, Nicolas ;
Valdes, Mariano ;
Voudris, Vassilis ;
Puricel, Serban ;
Slagboom, Ton ;
Goy, Jean-Jacques ;
den Heijer, Peter ;
van der Ent, Martin .
EUROINTERVENTION, 2015, 11 (03) :272-279
[37]   Impact of diabetes on clinical outcomes after revascularization with sirolimus-eluting and biolimus-eluting stents with biodegradable polymer from the SORT OUT VII trial [J].
Ellert, Julia ;
Christiansen, Evald Hoj ;
Maeng, Michael ;
Raungaard, Bent ;
Jensen, Svend Eggert ;
Kristensen, Steen Dalby ;
Veien, Karsten Tange ;
Junker, Anders Bo ;
Jakobsen, Lars ;
Aaroe, Jens ;
Terkelsen, Christian Juhl ;
Kahlert, Johnny ;
Villadsen, Anton Boel ;
Botker, Hans Erik ;
Jensen, Lisette Okkels .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (04) :567-573
[38]   Long-term outcomes with biodegradable polymer sirolimus- eluting stents versus durable polymer everolimus-eluting stents in ST-segment elevation myocardial infarction: 5-year follow-up of the BIOSTEMI randomised superiority trial [J].
Iglesias, Juan F. ;
Roffi, Marco ;
Losdat, Sylvain ;
Muller, Olivier ;
Degrauwe, Sophie ;
Kurz, David J. ;
Haegeli, Laurent ;
Weilenmann, Daniel ;
Kaiser, Christoph ;
Tapponnier, Maxime ;
Cook, Stephane ;
Cuculi, Florim ;
Heg, Dik ;
Windecker, Stephan ;
Pilgrim, Thomas .
LANCET, 2023, 402 (10416) :1979-1990
[39]   Biodegradable Polymer Versus Permanent Polymer Drug-Eluting Stents and Everolimus- Versus Sirolimus-Eluting Stents in Patients With Coronary Artery Disease 3-Year Outcomes From a Randomized Clinical Trial [J].
Byrne, Robert A. ;
Kastrati, Adnan ;
Massberg, Steffen ;
Wieczorek, Anna ;
Laugwitz, Karl-Ludwig ;
Hadamitzky, Martin ;
Schulz, Stefanie ;
Pache, Juergen ;
Fusaro, Massimiliano ;
Hausleiter, Joerg ;
Schoemig, Albert ;
Mehilli, Julinda .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (13) :1325-1331
[40]   Three-Year Outcomes After Revascularization With Everolimus and Sirolimus-Eluting Stents From the SORT OUT IV Trial [J].
Jensen, Lisette Okkels ;
Thayssen, Per ;
Maeng, Michael ;
Christiansen, Evald Hoj ;
Ravkilde, Jan ;
Hansen, Knud Norregaard ;
Kaltoft, Anne ;
Tilsted, Hans Henrik ;
Madsen, Morten ;
Lassen, Jens Flensted .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) :840-848