Optical coherence tomography findings: insights from the "randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions" (PRISON IV) trial

被引:0
作者
Teenwen, Koen [1 ]
Spoormans, Eva M. [1 ]
Bennett, Johan [2 ]
Dubois, Christophe [2 ]
Desmet, Walter [2 ]
Ughi, Giovanni J. [2 ]
Belmans, Ann
Kelder, Johannes C. [1 ]
Tijssen, Jan G. P.
Agostoni, Pierfrancesco [1 ]
Suttorp, Marrten J. [1 ]
Adriaenssens, Tom [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
[2] St Vincent Hosp, Dept Cardiac Med, Leuven, Belgium
关键词
chronic coronary total occlusion; drug-eluting stent; optical coherence tomography; stable angina; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; REGISTRY; CTO; MECHANISMS; COVERAGE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85%) patients underwent repeat angiography. Of these, 60 consecutive patients received optical coherence tomography divided over both stent groups. The mean number of struts analysed was 750 +/- 337 and 633 +/- 358 in SES and EES patients, respectively (p=0.07). The minimal lumen area, minimal stent area, maximal neointima area and neointimal thickness were comparable between the groups (4.8 +/- 2.1 and 4.4 +/- 1.5 mm2;5.3 +/- 1.8 and 5.3 +/- 1.4 mm2; 2.5 +/- 2.0 and 2.2 +/- 1.5 mm2; 0.7 +/- 1.7 and 0.4 +/- 0.2 mm). The percentage of uncovered struts was higher with EES (6.2 +/- 7.5% and 11.9 +/- 13.4%, p=0.04), whereas the percentage of malapposed struts and mean number of coronary evaginations were significantly higher with SES (2.9 +/- 4.0% and 1.2 +/- 2.4%, p=0.02; 18.5 +/- 17.7 and 5.3 +/- 3.1, p=0.004). Conclusions: The optical coherence tomography findings of this substudy demonstrated improved strut coverage with ultra-thin strut SES with bioresorbable polymer compared to thin-strut EES with durable polymer in CTO. On the other hand, SES showed a higher rate of stent strut malappositon and coronary evaginations. The clinical relevance of these findings remains to be demonstrated.
引用
收藏
页码:522 / 530
页数:9
相关论文
共 50 条
[21]   Ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents versus thin-strut, durable-polymer, everolimus-eluting stents for percutaneous coronary revascularisation: 5-year outcomes of the BIOSCIENCE randomised trial [J].
Pilgrim, Thomas ;
Piccolo, Raffaele ;
Heg, Dik ;
Roffi, Marco ;
Tuller, David ;
Muller, Olivier ;
Moarof, Igal ;
Siontis, George C. M. ;
Cook, Stephane ;
Weilenmann, Daniel ;
Kaiser, Christoph ;
Cuculi, Florim ;
Hunziker, Lukas ;
Eberli, Franz R. ;
Juni, Peter ;
Windecker, Stephan .
LANCET, 2018, 392 (10149) :737-746
[22]   Randomized Comparison of Sirolimus-Eluting and Everolimus-Eluting Coronary Stents in the Treatment of Total Coronary Occlusions Results From the Chronic Coronary Occlusion Treated by Everolimus-eluting Stent Randomized Trial [J].
Moreno, Raul ;
Garcia, Eulogio ;
Teles, Rui ;
Rumoroso, Jose-Ramon ;
Carvalho, Henrique Cyrne ;
Javier Goicolea, Francisco ;
Moreu, Jose ;
Mauri, Josefa ;
Sabate, Manel ;
Mainar, Vicente ;
Patricio, Lino ;
Valdes, Mariano ;
Vazquez, Felipez Fernandez ;
Sanchez-Recalde, Angel ;
Galeote, Guillermo ;
Jimenez-Valero, Santiago ;
Almeida, Manuel ;
Lopez de Sa, Esteban ;
Calvo, Luis ;
Plaza, Ignacio ;
Lopez-Sendon, Jose-Luis ;
Martin, Jose-Luis R. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) :21-28
[23]   Clinical and Angiographic Outcomes With Sirolimus-Eluting Stents in Total Coronary Occlusions The ACROSS/TOSCA-4 (Approaches to Chronic Occlusions With Sirolimus-Eluting Stents/Total Occlusion Study of Coronary Arteries-4) Trial [J].
Kandzari, David E. ;
Rao, Sunil V. ;
Moses, Jeffrey W. ;
Dzavik, Vladimir ;
Strauss, Bradley H. ;
Kutryk, Michael J. ;
Simonton, Charles A. ;
Garg, Jyotsna ;
Lokhnygina, Yuliya ;
Mancini, G. B. John ;
Yeoh, Eunice ;
Buller, Christopher E. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (02) :97-106
[24]   A randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer [J].
Tian, Feng ;
Chen, Yundai ;
Liu, Changfu ;
Jin, Qinhua ;
Chen, Lian ;
Sun, Zhijun ;
Liu, Hongbin ;
Guo, Jun ;
Gai, Luyue .
MOLECULAR MEDICINE REPORTS, 2013, 7 (04) :1191-1196
[25]   Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) [J].
Vlachojannis, Georgios J. ;
Smits, Pieter C. ;
Hofma, Sjoerd H. ;
Togni, Mario ;
Vazquez, Nicolas ;
Valdes, Mariano ;
Voudris, Vassilis ;
Slagboom, Ton ;
Goy, Jean-Jaques ;
den Heijer, Peter ;
van der Ent, Martin .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12) :1215-1221
[26]   Outcomes of patients treated with ultrathin-strut biodegradable polymer sirolimus-eluting stents versus fluoropolymer-based everolimus-eluting stents: a meta- analysis of randomised trials [J].
Cassese, Salvatore ;
Ndrepepa, Gjin ;
Byrne, Robert A. ;
Kufner, Sebastian ;
Lahmann, Anna Lena ;
Mankerious, Nader ;
Xhepa, Erion ;
Laugwitz, Karl-Ludwig ;
Schunkert, Heribert ;
Fusaro, Massimiliano ;
Kastrati, Adnan ;
Joner, Michael .
EUROINTERVENTION, 2018, 14 (02) :224-231
[27]   A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study [J].
Teeuwen, Koen ;
Adriaenssens, Tom ;
Van den Branden, Ben J. L. ;
Henriques, Jose P. S. ;
Van der Schaaf, Rene J. ;
Koolen, Jacques J. ;
Vermeersch, Paul H. M. J. ;
Bosschaert, Mike A. R. ;
Tijssen, Jan G. P. ;
Suttorp, Maarten J. .
TRIALS, 2012, 13
[28]   Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent Sequential Optical Coherence Tomography Study [J].
Ogura, Kunihiro ;
Tsujita, Hiroaki ;
Oishi, Yosuke ;
Matsumoto, Hidenari ;
Matsukawa, Naoki ;
Sakai, Rikuo ;
Arai, Taito ;
Sato, Shunya ;
Tanaka, Hideaki ;
Masaki, Ryota ;
Arai, Ken ;
Nomura, Kosuke ;
Kosaki, Ryota ;
Sakai, Koshiro ;
Sekimoto, Teruo ;
Kondo, Seita ;
Tsukamoto, Shigeto ;
Mori, Hiroyoshi ;
Yamamoto, Myong Hwa ;
Wakabayashi, Kohei ;
Suzuki, Hiroshi ;
Ochiai, Masahiko ;
Shinke, Toshiro .
INTERNATIONAL HEART JOURNAL, 2021, 62 (03) :510-519
[29]   Very thin strut biodegradable polymer everolimus-eluting and sirolimus-eluting stents versus durable polymer zotarolimus-eluting stents in allcomers with coronary artery disease (BIO-RESORT): a three-arm, randomised, non-inferiority trial [J].
von Birgelen, Clemens ;
Kok, Marlies M. ;
van der Heijden, Liefke C. ;
Danse, Peter W. ;
Schotborgh, Carl E. ;
Scholte, Martijn ;
Gin, R. Melvyn Tjon Joe ;
Somi, Samer ;
van Houwelingen, K. G. ;
Stoel, M. G. ;
de Man, Frits H. A. F. ;
Louwerenburg, J. W. ;
Hartmann, Marc ;
Zocca, Paolo ;
Linssen, Gerard C. M. ;
van der Palen, Job ;
Doggen, Carine J. M. ;
Lowik, Marije M. .
LANCET, 2016, 388 (10060) :2607-2617
[30]   Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent Results of the Randomized BIOFLOW-II Trial [J].
Windecker, Stephan ;
Haude, Michael ;
Neumann, Franz-Josef ;
Stangl, Karl ;
Witzenbichler, Bernhard ;
Slagboom, Ton ;
Sabate, Manel ;
Goicolea, Javier ;
Barragan, Paul ;
Cook, Stephane ;
Piot, Christophe ;
Richardt, Gert ;
Merkely, Bela ;
Schneider, Henrik ;
Bilger, Johannes ;
Erne, Paul ;
Waksman, Ron ;
Zaugg, Serge ;
Jueni, Peter ;
Lefevre, Thierry .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02)