Optical coherence tomography findings: insights from the "randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions" (PRISON IV) trial

被引:0
|
作者
Teenwen, Koen [1 ]
Spoormans, Eva M. [1 ]
Bennett, Johan [2 ]
Dubois, Christophe [2 ]
Desmet, Walter [2 ]
Ughi, Giovanni J. [2 ]
Belmans, Ann
Kelder, Johannes C. [1 ]
Tijssen, Jan G. P.
Agostoni, Pierfrancesco [1 ]
Suttorp, Marrten J. [1 ]
Adriaenssens, Tom [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
[2] St Vincent Hosp, Dept Cardiac Med, Leuven, Belgium
关键词
chronic coronary total occlusion; drug-eluting stent; optical coherence tomography; stable angina; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; REGISTRY; CTO; MECHANISMS; COVERAGE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85%) patients underwent repeat angiography. Of these, 60 consecutive patients received optical coherence tomography divided over both stent groups. The mean number of struts analysed was 750 +/- 337 and 633 +/- 358 in SES and EES patients, respectively (p=0.07). The minimal lumen area, minimal stent area, maximal neointima area and neointimal thickness were comparable between the groups (4.8 +/- 2.1 and 4.4 +/- 1.5 mm2;5.3 +/- 1.8 and 5.3 +/- 1.4 mm2; 2.5 +/- 2.0 and 2.2 +/- 1.5 mm2; 0.7 +/- 1.7 and 0.4 +/- 0.2 mm). The percentage of uncovered struts was higher with EES (6.2 +/- 7.5% and 11.9 +/- 13.4%, p=0.04), whereas the percentage of malapposed struts and mean number of coronary evaginations were significantly higher with SES (2.9 +/- 4.0% and 1.2 +/- 2.4%, p=0.02; 18.5 +/- 17.7 and 5.3 +/- 3.1, p=0.004). Conclusions: The optical coherence tomography findings of this substudy demonstrated improved strut coverage with ultra-thin strut SES with bioresorbable polymer compared to thin-strut EES with durable polymer in CTO. On the other hand, SES showed a higher rate of stent strut malappositon and coronary evaginations. The clinical relevance of these findings remains to be demonstrated.
引用
收藏
页码:522 / 530
页数:9
相关论文
共 50 条
  • [1] Randomized Multicenter Trial Investigating Angiographic Outcomes of Hybrid Sirolimus-Eluting Stents With Biodegradable Polymer Compared With Everolimus-Eluting Stents With Durable Polymer in Chronic Total Occlusions The PRISON IV Trial
    Teeuwen, Koen
    van der Schaaf, Rene J.
    Adriaenssens, Tom
    Koolen, Jacques J.
    Smits, Pieter C.
    Henriques, Jose P. S.
    Vermeersch, Paul H. M. J.
    Gin, R. Melvyn Tjon Joe
    Scholzel, Bastiaan E.
    Kelder, Johannes C.
    Tijssen, Jan G. P.
    Agostoni, Pierfrancesco
    Suttorp, Maarten J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (02) : 133 - 143
  • [2] Vascular Healing After Biodegradable Polymer Sirolimus-Eluting Versus Durable Polymer Everolimus-Eluting Stents in Chronic Total Occlusions
    Wang, Geng
    Li, Yi
    Lu, Wen
    Xu, Yawei
    Su, Xi
    Chen, Shaoliang
    Li, Yang
    Han, Yaling
    ARGET CTOOCT substudy Investigators
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2025, : 1124 - 1133
  • [3] Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography
    Tada, Tomohisa
    Byrne, Robert A.
    Schuster, Tibor
    Cuni, Rezarta
    Kitabata, Hironori
    Tiroch, Klaus
    Dirninger, Alfred
    Gratze, Franz
    Kaspar, Klaus
    Zenker, Gerald
    Joner, Michael
    Schomig, Albert
    Kastrati, Adnan
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2013, 14 (02) : 84 - 89
  • [4] Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial
    Kandzari, David E.
    Mauri, Laura
    Koolen, Jacques J.
    Massaro, Joseph M.
    Doros, Gheorghe
    Garcia-Garcia, Hector M.
    Bennett, Johan
    Roguin, Ariel
    Gharib, Elie G.
    Cutlip, Donald E.
    Waksman, Ron
    LANCET, 2017, 390 (10105) : 1843 - 1852
  • [5] Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction
    Pilgrim, Thomas
    Piccolo, Raffaele
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Vuilliomenet, Andre
    Muller, Olivier
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Khattab, Ahmed A.
    Taniwaki, Masanori
    Rigamonti, Fabio
    Nietlispach, Fabian
    Blochlinger, Stefan
    Wenaweser, Peter
    Juni, Peter
    Windecker, Stephan
    EUROINTERVENTION, 2016, 12 (11) : E1343 - E1354
  • [6] Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial)
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Kawamura, Masaki
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    EUROINTERVENTION, 2015, 11 (05) : 564 - 571
  • [7] Five-Year Outcomes in Patients With Diabetes Mellitus Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents
    Iglesias, Juan F.
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Lanz, Jonas
    Rigamonti, Fabio
    Mueller, Olivier
    Moarof, Igal
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Cuculi, Florim
    Valgimigli, Marco
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [8] Randomised comparison of vascular response to biodegradable polymer sirolimus eluting and permanent polymer everolimus eluting stents: An optical coherence tomography study
    Koppara, Tobias
    Tada, Tomohisa
    Xhepa, Erion
    Kutner, Sebastian
    Byrne, Robert A.
    Ibrahim, Tareq
    Laugwitz, Karl -Ludwig
    Kastrati, Adnan
    Joner, Michael
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 258 : 42 - 49
  • [9] Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial
    Pilgrim, Thomas
    Roffi, Marco
    Tueller, David
    Muller, Olivier
    Vuilliomenet, Andre
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Heg, Dik
    Jueni, Peter
    Windecker, Stephan
    AMERICAN HEART JOURNAL, 2014, 168 (03) : 256 - 261
  • [10] Angiographic outcomes of Orsiro biodegradable polymer sirolimus-eluting stents and Resolute Integrity durable polymer zotarolimus-eluting stents: results of the ORIENT trial
    Kang, Si-Hyuck
    Chung, Woo-Young
    Lee, Joo Myung
    Park, Jin-Joo
    Yoon, Chang-Hwan
    Suh, Jung-Won
    Cho, Young-Seok
    Doh, Joon-Hyung
    Cho, Jin Man
    Bae, Jang-Whan
    Youn, Tae-Jin
    Chae, In-Ho
    EUROINTERVENTION, 2017, 12 (13) : 1623 - 1631