Structural performance of RC shear walls with post-construction openings strengthened with FRP composite laminates

被引:32
作者
Mosallam, Ayman S. [1 ]
Nasr, Ahmed [2 ]
机构
[1] Univ Calif Irvine, Irvine, CA 92697 USA
[2] Monifia Univ, Monifia, Egypt
关键词
Laminates; Polymer-matrix composites (PMCs); Debonding; Strength; Analytical modeling; Mechanical testing; Wet lay-up; RETROFIT; TESTS;
D O I
10.1016/j.compositesb.2016.06.063
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Over the past few decades, retrofitting of existing buildings, rather than new construction, became more popular due to economic reasons and the benefit of shorter service interruptions of constructed facilities. Change of use of an existing building may require the removal of portions of the structural members such as introducing door and window openings in an existing shear walls. In these scenarios, a remedial external retrofit is needed to restore the structural integrity and to regain building's seismic ductility. This paper presents the results of an experimental study that aimed at evaluating the structural performance of reinforced concrete (RC) shear walls, with different opening geometries strengthened with fiber-reinforced-polymer (FRP) carbon/epoxy composites laminates. Experimental results indicated that the proposed FRP lamination system for RC shear walls with post-construction openings was successful in enhancing both the strength and ductility of retrofitted walls. The average strength gain and ductility enhancement of the retrofitted walls, as compared to the unstrengthened walls ranged from 20% to 28%. An analytical procedures for analyzing retrofitted reinforced concrete with different opening geometries is also presented. For design purposes, a proposed efficiency factor that accounts for the efficiency of different lamination protocols is discussed. Conclusions and recommendations for future research are presented. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:488 / 504
页数:17
相关论文
共 26 条
[1]  
ACI Committee 318, 2019, CODE31819 ACI, DOI DOI 10.14359/51716937
[2]  
[Anonymous], 2008, ACI 4402R 08
[3]  
[Anonymous], 2013, AC178 ICC ES
[4]  
[Anonymous], 2013, AC125 IEE ES
[5]  
[Anonymous], 2007, ASCESEI 41 06
[6]  
Cruz-Noguez CA, 2014, P 10 US NAT C EARTHQ
[7]  
CSI (Computers and Structures Inc.), 2004, SAP2000 V10 INT FIN
[8]  
Demeter I, 2010, P 14 EUR C EARTHQ EN
[9]   Shake Table Tests on FRP-Rehabilitated RC Shear Walls [J].
El-Sokkary, H. ;
Galal, K. ;
Ghorbanirenani, I. ;
Leger, P. ;
Tremblay, R. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (01) :79-90
[10]   Experimental investigation of seismic repair and retrofit of bridge columns by composite jackets [J].
Haroun, MA ;
Mosallam, AS ;
Feng, MQ ;
Elsanadedy, HM .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2003, 22 (14) :1243-1268