Evaluation of a computer-aided method for measuring the Cobb angle on chest X-rays

被引:82
作者
Pan, Yaling [1 ]
Chen, Qiaoran [2 ]
Chen, Tongtong [1 ]
Wang, Hanqi [1 ]
Zhu, Xiaolei [1 ]
Fang, Zhihui [3 ]
Lu, Yong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Radiol, Shanghai 200025, Peoples R China
[2] Shenzhen Yi Yuan Intelligence Co Ltd, Shenzhen 518064, Guangdong, Peoples R China
[3] Shanghai Qual Creat Intelligent Technol Co Ltd, Shanghai 200050, Peoples R China
关键词
Chest X-rays; Cobb angle; Computer-aided; Deep learning; Scoliosis; RELIABILITY-ANALYSIS; SCOLIOSIS;
D O I
10.1007/s00586-019-06115-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives To automatically measure the Cobb angle and diagnose scoliosis on chest X-rays, a computer-aided method was proposed and the reliability and accuracy were evaluated. Methods Two Mask R-CNN models as the core of a computer-aided method were used to separately detect and segment the spine and all vertebral bodies on chest X-rays, and the Cobb angle of the spinal curve was measured from the output of the Mask R-CNN models. To evaluate the reliability and accuracy of the computer-aided method, the Cobb angles on 248 chest X-rays from lung cancer screening were measured automatically using a computer-aided method, and two experienced radiologists used a manual method to separately measure Cobb angles on the aforementioned chest X-rays. Results For manual measurement of the Cobb angle on chest X-rays, the intraclass correlation coefficients (ICC) of intra- and inter-observer reliability analysis was 0.941 and 0.887, respectively, and the mean absolute differences were < 3.5 degrees. The ICC between the computer-aided and manual methods for Cobb angle measurement was 0.854, and the mean absolute difference was 3.32 degrees. These results indicated that the computer-aided method had good reliability for Cobb angle measurement on chest X-rays. Using the mean value of Cobb angles in manual measurements > 10 degrees as a reference standard for scoliosis, the computer-aided method achieved a high level of sensitivity (89.59%) and a relatively low level of specificity (70.37%) for diagnosing scoliosis on chest X-rays. Conclusion The computer-aided method has potential for automatic Cobb angle measurement and scoliosis diagnosis on chest X-rays. Graphic abstract These slides can be retrieved under Electronic Supplementary Material.
引用
收藏
页码:3035 / 3043
页数:9
相关论文
共 20 条
[1]  
[Anonymous], NEURAL COMPUT APPL
[2]  
Bonanni PG, 2017, INT J SPINE SURG, V11, DOI 10.14444/4022
[3]   Inter- and intraobserver reliability assessment of the Cobb angle: manual versus digital measurement tools [J].
Gstoettner, Michaela ;
Sekyra, Katrin ;
Walochnik, Nadja ;
Winter, Peter ;
Wachter, Roland ;
Bach, Christian M. .
EUROPEAN SPINE JOURNAL, 2007, 16 (10) :1587-1592
[4]   Reliability analysis of Cobb measurement in degenerative lumbar scoliosis using endplate versus pedicle as bony landmarks [J].
Guo, Jing ;
Deng, Xian-chao ;
Ling, Qin-jie ;
Yin, Zhi-xun ;
He, Er-xing .
POSTGRADUATE MEDICINE, 2017, 129 (07) :762-767
[5]  
He KM, 2020, IEEE T PATTERN ANAL, V42, P386, DOI [10.1109/ICCV.2017.322, 10.1109/TPAMI.2018.2844175]
[6]   Clinical Evaluation, Imaging, and Management of Adolescent Idiopathic and Adult Degenerative Scoliosis [J].
Kim, Wonsuk ;
Porrino, Jack A. ;
Hood, Kenneth A. ;
Chadaz, Tyson S. ;
Klauser, Andrea S. ;
Taljanovic, Mihra S. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2019, 48 (04) :402-414
[7]   Measuring procedures to determine the Cobb angle in idiopathic scoliosis: a systematic review [J].
Langensiepen, S. ;
Semler, O. ;
Sobottke, R. ;
Fricke, O. ;
Franklin, J. ;
Schoenau, E. ;
Eysel, P. .
EUROPEAN SPINE JOURNAL, 2013, 22 (11) :2360-2371
[8]   Feature Pyramid Networks for Object Detection [J].
Lin, Tsung-Yi ;
Dollar, Piotr ;
Girshick, Ross ;
He, Kaiming ;
Hariharan, Bharath ;
Belongie, Serge .
30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, :936-944
[9]   MEASUREMENT OF THE COBB ANGLE ON RADIOGRAPHS OF PATIENTS WHO HAVE SCOLIOSIS - EVALUATION OF INTRINSIC ERROR [J].
MORRISSY, RT ;
GOLDSMITH, GS ;
HALL, EC ;
KEHL, D ;
COWIE, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :320-327
[10]   Reliability Analysis of a Smartphone-aided Measurement Method for the Cobb Angle of Scoliosis [J].
Qiao, Jun ;
Liu, Zhen ;
Xu, Leilei ;
Wu, Tao ;
Zheng, Xin ;
Zhu, Zezhang ;
Zhu, Feng ;
Qian, Bangpin ;
Qiu, Yong .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (04) :E67-E71