Analysis of triacylglycerol and fatty acid isomers by low-temperature silver-ion high performance liquid chromatography with acetonitrile in hexane as solvent: Limitations of the methodology

被引:15
作者
Adlof, R. [1 ]
机构
[1] USDA ARS, Natl Ctr Agr Utilizat Res, Peoria, IL 61604 USA
关键词
silver; HPLC; low-temperature; triacylglycerol; fatty acid ester; isomers;
D O I
10.1016/j.chroma.2007.03.070
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Silver ion HPLC (Ag-HPLC), utilizing columns containing silver ions bonded to a silica substrate and acetonitrile in hexane as solvent, has proven to be a powerful technology for the analysis of geometric (cis or trans) or positional fatty acids, fatty acid ester (primarily methyl ester; FAME), or triacylglycerol (TAG) isomers. Previous studies had demonstrated that, unlike gas chromatography, samples eluted more rapidly at lower temperatures (at 20 degrees C versus 40 degrees C, for example). A low-temperature bath [dual-column Ag-HPLC; isocratic solvent systems of 0.3 to 0.7% acetonitrile (ACN) in hexane] was utilized to study the application of this system at low (below 0 degrees C) temperatures for analysis of FAME (zero to six double bonds) and TAG [SSS, OOO and LLL, where S = stearic acid (18:0), 0 = oleic acid (9c - 18: 1), and L = linoleic acid (9c, 12c - 18:2)] standards. While FAME elution times continued to decrease from 0 degrees C to -10 degrees C, they began to increase at -20 degrees C. A similar situation was noted for the TAG isomers, except that retention times began to increase below 0 degrees C. The lower temperature limit of the Ag-HPLC/ACN in hexane system is thus ca. -25 degrees C. Increasing sample elution times and pump head pressures upon sample injection were noted at temperatures of -25 degrees C to -40 degrees C. Equilibration times at each temperature could be reduced to ca. 15 min without loss of resolution and with retention times of 2%. Temperature, rather than solvent composition, can therefore be utilized with the Ag-HPLC/ACN in hexane solvent system to optimize elution times and resolution(s) of FAME and TAG isomers. Published by Elsevier B.V.
引用
收藏
页码:256 / 259
页数:4
相关论文
共 26 条
[1]   Analysis of triglyceride isomers by silver-ion high-performance liquid chromatography - Effect of column temperature on retention times [J].
Adlof, R ;
List, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :109-113
[2]  
Adlof R. O., 1995, J HIGH RES CHROMATOG, V18, P105
[3]   Normal-phase separation effects with lipids on a silver ion high-performance liquid chromatography column [J].
Adlof, RO .
JOURNAL OF CHROMATOGRAPHY A, 1997, 764 (02) :337-340
[4]   Analysis of fatty acid mono- and diacylglycerol positional isomers by silver ion high-performance liquid chromatography [J].
Adlof, RO .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (01) :135-138
[5]   SEPARATION OF CIS AND TRANS UNSATURATED FATTY-ACID METHYL-ESTERS BY SILVER ION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ADLOF, RO .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :95-99
[6]   SILVER ION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF FATTY-ACID METHYL-ESTERS LABELED WITH DEUTERIUM ATOMS ON THE DOUBLE-BONDS [J].
ADLOF, RO ;
EMKEN, EA .
JOURNAL OF CHROMATOGRAPHY A, 1994, 685 (01) :178-181
[7]   ANALYSIS OF THE MONOENOIC FATTY-ACID DISTRIBUTION IN HYDROGENATED VEGETABLE-OILS BY SILVER-ION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ADLOF, RO ;
COPES, LC ;
EMKEN, EA .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1995, 72 (05) :571-574
[8]  
ADLOF RO, 2006, LIPID ANAL LIPIDOMIC, P175
[9]   ARGENTATION SUPERCRITICAL-FLUID CHROMATOGRAPHY FOR QUANTITATIVE-ANALYSIS OF TRIACYLGLYCEROLS [J].
BLOMBERG, LG ;
DEMIRBUKER, M ;
ANDERSSON, PE .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1993, 70 (10) :939-946
[10]   Determination of fatty acids in vegetable oil by reversed-phase liquid chromatography with fluorescence detection [J].
Chen, SH ;
Chen, KC ;
Lien, HM .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (02) :357-369