Simultaneous spectrophotometric determination of carbamazepine and phenytoin in serum by PLS regression and comparison with HPLC

被引:0
作者
Rezaei, Z
Hemmateenejad, B
Khabnadideh, S
Gorgin, M
机构
[1] Shiraz Univ Med Sci, Med & Nat Prod Chem Res Ctr, Shiraz 71345, Iran
[2] Shiraz Univ Med Sci, Sch Pharm, Dept Med Chem, Shiraz, Iran
关键词
carbamazepine; phenytoin; PLS; plasma; HPLC; spectrophotometry;
D O I
10.1016/j.talantra.2004.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbamazepine (CBZ) and phenytoin (PHT) are two antiepileptic drugs which are used simultaneously. In this paper a partial least-squares (PLS) calibration method is described for the simultaneous spectrophotometric determination of CBZ and PHT in plasma. Standard binary mixtures of CBZ and PHT have been resolved by application of PLS-1 to their UV spectra. Then, the binary standard solutions, spiked to plasma, were prepared and after the extraction of the drugs, their corresponding UV spectrum were analyzed by PLS regression to calculate the concentration of drugs in unknown plasma. A leave one out cross-validation procedure was employed to find the optimum numbers of latent variables using PRESS. A HPLC method was also applied for simultaneous determination of two drugs in the plasma and in methanol. The mean recoveries obtained by PLS were 98.4 and 98.2 for CBZ and PHT and those obtained by HPLC were 100.1 and 101.7, respectively. Although. the HPLC method showed better performance than PLS, it was found that the results obtained by PLS were comparable with those obtained by HPLC method. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 55 条
[1]   First- and second-order multivariate calibration applied to biological samples: determination of anti-inflammatories in serum and urine [J].
Arancibia, JA ;
Olivieri, AC ;
Escandar, GM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :451-459
[2]   Does carbamazepine have a narrow therapeutic plasma concentration range? [J].
Bialer, M ;
Levy, RH ;
Perucca, E .
THERAPEUTIC DRUG MONITORING, 1998, 20 (01) :56-59
[3]   Multivariate detection limits estimators [J].
Boque, R ;
Rius, FX .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (01) :11-23
[4]   Phenytoin auto-induction [J].
Chetty, M ;
Miller, R ;
Seymour, MA .
THERAPEUTIC DRUG MONITORING, 1998, 20 (01) :60-62
[5]   Simultaneous quantitative determination of isolated trans fatty acids and conjugated linoleic acids in oils and fats by chernometric analysis of the infrared profiles [J].
Christy, AA ;
Egeberg, PK ;
Ostensen, ET .
VIBRATIONAL SPECTROSCOPY, 2003, 33 (1-2) :37-48
[6]   Synchronous fluorimetric determination of salicylic acid and diflunisal in human serum using partial least-squares calibration [J].
delaPena, AM ;
Moreno, MD ;
DuranMeras, I ;
Salinas, F .
TALANTA, 1996, 43 (08) :1349-1356
[7]   Dissolution and assaying of multicomponent tablets by chemometric methods using computer-aided spectrophotometer [J].
Dinç, E ;
Serin, C ;
Tugcu-Demiröz, F ;
Doganay, T .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2003, 250 (02) :339-350
[8]   Spectrophotometric multicomponent analysis of a mixture of metamizol, acetaminophen and caffeine in pharmaceutical formulations by two chemometric techniques [J].
Dinç, E ;
Baleanu, D ;
Onur, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (5-6) :949-957
[9]   Mutlivariate calibration with Raman data using fast principal component regression and partial least squares methods [J].
Estienne, F ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :123-129
[10]  
Faber K, 1997, J CHEMOMETR, V11, P419, DOI 10.1002/(SICI)1099-128X(199709/10)11:5<419::AID-CEM486>3.0.CO