Successful use of recombinant factor VIIa in the control of a massive bleeding in two patients with biventricular assist device (Thoratec®)

被引:2
作者
Fritsch, N. [1 ]
Pouquet, O. [1 ]
Roux, B. [1 ]
Abdelmoumen, Y. [1 ]
Janvier, G. [1 ]
机构
[1] CHU Bordeaux, Hop Haut Leveque, Serv Reanimat Chirurg Cardiaque, F-33600 Pessac, France
来源
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION | 2010年 / 29卷 / 01期
关键词
Activated recombinant factor VII; Biventricular assistance; Massive bleeding; ACTIVATED FACTOR-VII; CARDIAC-SURGERY; ADJUNCTIVE THERAPY; IMPLANTATION;
D O I
10.1016/j.annfar.2009.10.017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Massive bleeding is a dreaded complication of biventricular mechanical assistance implantation. Its origin is multifactorial. Blood products transfusion associated with correction of coagulopathy are sometimes insufficient. We report two cases of massive bleeding after a Thoratec (R) biventricular assistance implantation. After surgical haemostasis failure and despite the correction of coagulation disorders, a major bleeding persisted, so these patients received a single injection of 90 mu g/kg of rFVIIa. This allowed in both cases a significant reduction of the bleeding and the restoration of normal haemodynamic conditions. This treatment was not complicated by any thrombotic accident. (C) 2009 Published by Elsevier Masson SAS.
引用
收藏
页码:45 / 47
页数:3
相关论文
共 15 条
  • [1] Acute left atrial thrombus after recombinant factor VIIa administration during left ventricular assist device implantation in a patient with heparin-induced thrombocytopenia
    Apostolidou, Ioanna
    Sweeney, Michael F.
    Missov, Emil
    Joyce, Lyle D.
    John, Ranjit
    Prielipp, Richard C.
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (02) : 404 - 408
  • [2] Recombinant factor VIIa as adjunctive therapy for bleeding control in severely injured trauma patients: Two parallel randomized, placebo-controlled, double-blind clinical trials
    Boffard, KD
    Riou, B
    Warren, B
    Choong, PIT
    Rizoli, S
    Rossaint, R
    Axelsen, M
    Kluger, Y
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (01): : 8 - 16
  • [3] Results following implantation of mechanical circulatory support systems: The Montreal Heart Institute experience
    El-Hamamsy, Ismail
    Jacques, Frederic
    Perrault, Louis P.
    Bouchard, Denis
    Demers, Philippe
    White, Michel
    Pelletier, Guy B.
    Racine, Normand
    Pellerin, Michel
    Carrier, Michel
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2009, 25 (02) : 107 - 110
  • [4] Recombinant activated factor VII (Novo7®) in patients with ventricular assist devices: Case report and review of the current literature
    Heise, Daniel
    Braeuer, Anselm
    Quintel, Michael
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2007, 2 (1)
  • [5] Karkouti K, 2007, CAN J ANAESTH, V54, P573, DOI 10.1007/BF03022322
  • [6] Karkouti K, 2006, CAN J ANAESTH, V53, P802, DOI 10.1007/BF03022797
  • [7] Recombinant factor VIIa as an adjunctive therapy for patients requiring large volume transfusion: a pharmacoeconomic evaluation
    Loudon, B
    Smith, MP
    [J]. INTERNAL MEDICINE JOURNAL, 2005, 35 (08) : 463 - 467
  • [8] Recombinant factor VIIa in the treatment of postoperative hemorrhage after cardiac surgery
    Raivio, P
    Suojaranta-Ylinen, R
    Kuitunen, AH
    [J]. ANNALS OF THORACIC SURGERY, 2005, 80 (01) : 66 - 71
  • [9] Small-dose recombinant activated factor VII (NovoSeven®) in cardiac surgery
    Romagnoli, S
    Bevilacqua, S
    Gelsomino, S
    Pradella, S
    Ghilli, L
    Rostagno, C
    Gensini, GF
    Sorbara, C
    [J]. ANESTHESIA AND ANALGESIA, 2006, 102 (05) : 1320 - 1326
  • [10] Long-term use of a left ventricular assist device for end-stage heart failure
    Rose, EA
    Gelijns, AC
    Moskowitz, AJ
    Heitjan, DF
    Stevenson, LW
    Dembitsky, W
    Long, JW
    Ascheim, DD
    Tierney, AR
    Levitan, RG
    Watson, JT
    Meier, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (20) : 1435 - 1443