Difference of uveal parameters between the acute primary angle closure eyes and the fellow eyes

被引:17
作者
Li, Xingyi [1 ]
Wang, Wei [1 ]
Huang, Wenbin [1 ]
Chen, Shida [1 ]
Wang, Jiawei [1 ]
Wang, Zhonghao [1 ]
Liu, Yaoming [1 ]
He, Mingguang [1 ]
Zhang, Xiulan [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
OPTICAL COHERENCE TOMOGRAPHY; INCREASED CHOROIDAL THICKNESS; ULTRASOUND BIOMICROSCOPY; CILIARY BODY; QUANTITATIVE MEASUREMENTS; GLAUCOMA; TRABECULECTOMY; POPULATION; PRESSURE;
D O I
10.1038/s41433-018-0056-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To measure the anterior and posterior ocular biometric characteristics concurrently and to explore the relationship between iris, ciliary body and choroid in acute primary angle closure eyes (APAC) and fellow eyes. Methods It is a prospective, cross-sectional study. Thirty patients with recent APAC were finally enroled in it. Anterior and posterior uveal parameters were measured simultaneously by anterior segment optical coherence tomography (AS-OCT), swept-source optical coherence tomography (SS-OCT) and ultrasound biomicroscopy (UBM). The parameters were measured including: pupil diameter (PD); iris thickness, curvature (ICURV), area (IAREA); anterior chamber depth (ACD), width (ACW), area (ACA), volume (ACV); lens vault (LV); choroidal thickness and retinal thickness; maximum ciliary body thickness (CBTmax); ciliary body thickness at the point of the scleral spur (CBTO) and 1000 mm away (CBT1000); anterior placement of the ciliary body (APCB); and trabecular-ciliary angle (TCA). Results Compared with fellow eyes, APAC eyes had narrower anterior biometric parameters and presented with smaller anterior segment parameters (including ACD and ACW); (p < 0.01)), smaller IAREA and ICURV (p < 0.001), larger LV (p = 0.035), thinner ciliary body and less anterior ciliary process (p < 0.01). After adjustment for potential confounders (axial length, spherical equivalent and PD), APCB was positive correlated with choroidal thickness and CBT, and CBT was positive correlated with choroidal thickness. Conclusions Compared with fellow eyes, APAC eyes had narrower anterior biometric parameters, thinner ciliary body and smaller iris area and curvature. APCB, CBT and choroidal thickness were positively correlated. However, further studies are required before these conclusions are generalised.
引用
收藏
页码:1174 / 1182
页数:9
相关论文
共 26 条
  • [1] Acute primary angle closure in an Asian population - Long-term outcome of the fellow eye after prophylactic laser peripheral iridotomy
    Ang, LPK
    Aung, T
    Chew, PTK
    [J]. OPHTHALMOLOGY, 2000, 107 (11) : 2092 - 2096
  • [2] Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations
    Aung, T
    Nolan, WP
    Machin, D
    Seah, SKL
    Baasanhu, J
    Khaw, PT
    Johnson, GJ
    Foster, PJ
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (04) : 527 - 532
  • [3] Changes in Choroidal Thickness After Trabeculectomy in Primary Angle Closure Glaucoma
    Chen, Shida
    Wang, Wei
    Gao, Xinbo
    Li, Zheng
    Huang, Wenbing
    Li, Xingyi
    Zhou, Minwen
    Zhang, Xiulan
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) : 2608 - 2613
  • [4] The definition and classification of glaucoma in prevalence surveys
    Foster, PJ
    Buhrmann, R
    Quigley, HA
    Johnson, GJ
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (02) : 238 - 242
  • [5] Errors in ultrasound digital image distance measurements
    Goldstein, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (07) : 1125 - 1132
  • [6] Changes in choroidal thickness and optical axial length accompanying intraocular pressure increase
    Hata, Masayuki
    Hirose, Fumitaka
    Oishi, Akio
    Hirami, Yasuhiko
    Kurimoto, Yasuo
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (06) : 564 - 568
  • [7] Comparison of Ciliary Body Anatomy between American Caucasians and Ethnic Chinese Using Ultrasound Biomicroscopy
    He, Na
    Wu, Lingling
    Qi, Meng
    He, Mingguang
    Lin, Shan
    Wang, Xin
    Yang, Fan
    Fan, Xiang
    [J]. CURRENT EYE RESEARCH, 2016, 41 (04) : 485 - 491
  • [8] Huang W, 2015, PLOS ONE, V10
  • [9] Qualitative Assessment of Ultrasound Biomicroscopic Images Using Standard Photographs: The Liwan Eye Study
    Jiang, Yuzhen
    He, Mingguang
    Huang, Wenyong
    Huang, Qunxiao
    Zhang, Jian
    Foster, Paul J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (04) : 2035 - 2042
  • [10] KIEL JW, 1995, INVEST OPHTH VIS SCI, V36, P579