Simulation Analysis of Flashover Characteristics of 220kV Composite Insulators Based on Finite-Element Method

被引:1
|
作者
Ming, Lei [1 ]
Jiang, Zeng [1 ]
Gang, Liu [1 ]
机构
[1] S China Univ Technol, Sch Elect Power, Guangzhou 510640, Guangdong, Peoples R China
来源
ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3 | 2009年
关键词
flashover features; gas discharge; flashover voltage; flashover path; circuit model; POLLUTED INSULATORS; VOLTAGE; VACUUM;
D O I
10.1109/ICPADM.2009.5252335
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to enhance the ability to anti-pollution flashover, a new measurement taking composite insulators instead of glass insulators is adopted. In order to grasp the impact of flashover features of lightning striking insulators, the mechanism of insulators discharge, contrast level of composites insulators and glass insulators lightning flashover voltage as well as differences in flashover features of lightning striking, this paper carries on electric field simulation for insulators loaded with positive DC voltage through computer simulation software studying the dynamic changes of the electric field, and lightning flashover insulator process is derived by combining with gas-discharge theory. By comparing the field level of different section of the glass and synthetic insulators and variation of field strength with time-variation, the path of the respective insulator flashover is forecasted. And on this basis, establish the circuit model of Are - air flashover for solving the minimum flashover voltage in the use of differential calculation, Combine with the final test to verify. The results show that the flashover circuit model is built in accordance with the experimental results; Lightning strike flashover performance of composite insulator with ring is better than glass insulators.
引用
收藏
页码:697 / 700
页数:4
相关论文
共 50 条
  • [1] The Research of 220kV Transformer Optimization Design Based on Finite Element Analysis Method
    Li, Shenghui
    Sun, Feng
    Li, Mingyu
    Wang, Chao
    Li, Xinwei
    Yuan, Peng
    Zeng, Hui
    2019 CHINESE AUTOMATION CONGRESS (CAC2019), 2019, : 5800 - 5803
  • [2] Influence of Shed Configuration on Icing Characteristics and Flashover Performance of 220 kV Composite Insulators
    Hu, Qin
    Wang, Shijing
    Shu, Lichun
    Jiang, Xingliang
    Qiu, Gang
    Li, Hantao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 319 - 330
  • [3] Influence of AC electrical field on 220 kV composite insulators icing and flashover characteristics
    Yuan, Wei
    Shu, Lichun
    Jiang, Xingliang
    Hu, Qin
    Wang, Shijing
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (06): : 1541 - 1548
  • [4] Mechanical Characteristics Analysis of 220kV Three Core Submarine Cable Anchoring Accidents Based on Finite Element Method
    Lei, Zhicheng
    Huang, Xuancheng
    Mei, Rui
    Liu, Quan
    Zhang, Dapeng
    Yu, Huan
    Pan, Wenxia
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 574 - 579
  • [5] Effect of icing on the AC flashover voltage of 220 kV composite insulators
    Wang, Huan
    Hu, Qin
    Lin, Huiyao
    Xu, Hang
    Shu, Lichun
    Yin, Pancheng
    Jiang, Xingliang
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 238
  • [6] Effects of icing degree on ice growth characteristics and flashover performance of 220 kV composite insulators
    Hu, Qin
    Wang, Shijing
    Yang, Hongjun
    Shu, Lichun
    Jiang, Xingliang
    Li, Hantao
    Qi, Jiahao
    Liu, Yanqing
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2016, 128 : 47 - 56
  • [7] AC Icing Flashover Characteristics and Maximum Withstand Voltage Gradient of 220 kV Polluted Composite Insulators
    Wang, Huan
    Hu, Qin
    Shu, Lichun
    Yin, Pancheng
    Wu, Yufan
    Jiang, Xingliang
    Yu, Zhou
    Wang, Li
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 2161 - 2168
  • [8] Simulation of the Composite Electric Field on 170 kV Disconnector Using the Finite-Element Method
    Yazici, Mirac
    Kalenderli, Ozcan
    Ispirli, Mehmet Murat
    ELECTRICA, 2024, 24 (01): : 87 - 95
  • [9] Effect of Grading Ring on Ice Characteristics and Flashover Performance of 220 kV Composite Insulators with Different Shed Configurations
    Shu, Lichun
    Wang, Shijing
    Jiang, Xingliang
    Hu, Qin
    Yang, Xiuyu
    Yang, Shuang
    Chen, Ji
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 951 - 960
  • [10] Influence of polluting methods on icing and flashover characteristics of 220 kV composite insulators under ac working voltage
    State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing
    400044, China
    不详
    400015, China
    Zhongguo Dianji Gongcheng Xuebao, 18 (4817-4824):