Preliminary Evaluation of a Combined MicroPET®-MR System

被引:18
作者
Hawkes, R. C. [1 ]
Fryer, T. D. [1 ]
Siegel, S. [3 ]
Ansorge, R. E. [2 ]
Carpenter, T. A. [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[3] Preclin Solut, Siemens Mol Imaging, Knoxville, TN 37932 USA
基金
英国工程与自然科学研究理事会;
关键词
PET; MRI; Positron emission tomography; Magnetic resonance imaging; Multimodality Imaging; PET SCANNER; PERFORMANCE EVALUATION; POSITRON TOMOGRAPH; SENSITIVITY; COILS;
D O I
10.1177/153303461000900106
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
There are many motivations for adding simultaneously acquired MR images to PET scanning. The most straight forward are, superior registration of MR and PET images, the addition of morphological detail when there is non-rigid motion and for pre-clinical studies simultaneous imaging could lead to a significant reduction in the time that animals are required to be anesthetised. In addition simultaneous MR has the potential to provide accurate motion correction for PET image reconstruction. For functional imaging simultaneous acquisition is required to assess the subject in the same physiological state, such as acute stroke studies. The elimination of the additional radiation associated with combining CT with PET, by providing anatomic detail with MR, would be a crucial advantage for cancer screening. Combining the two instruments necessitates some engineering tradeoffs, especially associated with the use of the highly developed photomultiplier tube (PMT) used for light amplification, because of its incompatibility with strong magnetic fields. Our approach is to provide a split in the magnet and gradients to locate the magnetic sensitive components, the PMTs, in regions of low magnetic field, leaving only the essential PET components, the scintillator blocks, in the strong magnetic field region. The crystals are coupled to the PMTs by extending the optical fibres. A further advantage accrues by moving the PET electronics out of the region seen by the MR radio-frequency (RF) and gradient coils as electromagnetic interference effects between the PET and MR systems, which could cause artefacts in either modality, are eliminated. Here we describe a preliminary evaluation of the system, which is essentially a microPET Focus-120 located in a 1 T split magnet, and compare its performance to previous microPET instruments.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [41] Combined modality PET/MR for the detection of severe large vessel vasculitis
    Cerne, John W.
    Liu, Sophia
    Umair, Muhammad
    Pathrose, Ashitha
    Moore, Jackson E.
    Allen, Bradley D.
    Markl, Michael
    Carr, James C.
    Savas, Hatice
    Wilsbacher, Lisa
    Avery, Ryan
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2022, 6 (01):
  • [42] Preliminary Study of MR and Fluorescence Dual-mode Imaging: Combined Macrophage-Targeted and Superparamagnetic Polymeric Micelles
    Li, Wen-Juan
    Wang, Yong
    Liu, Yulin
    Wu, Teng
    Cai, Wen-Li
    Shuai, Xin-Tao
    Hong, Guo-Bin
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2018, 15 (02): : 129 - 141
  • [43] Evaluation of glymphatic system activity using diffusion tensor image analysis along the perivascular space and amyloid PET in older adults with objectively normal cognition: a preliminary study
    Park, Chae Jung
    Kim, Sang-Young
    Kim, Jun Hwee
    Son, Nak-Hoon
    Park, Jin Young
    Jeong, Yong Hyu
    Kim, Hyun Jeong
    Park, Jaesub
    Kim, Woo Jung
    FRONTIERS IN AGING NEUROSCIENCE, 2023, 15
  • [44] PET/MR Imaging in the Detection and Characterization of Pulmonary Lesions: Technical and Diagnostic Evaluation in Comparison to PET/CT
    Rauscher, Isabel
    Eiber, Matthias
    Furst, Sebastian
    Souvatzoglou, Michael
    Nekolla, Stephan G.
    Ziegler, Sibylle I.
    Rummeny, Ernst J.
    Schwaiger, Markus
    Beer, Ambros J.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (05) : 724 - 729
  • [45] Defining clinical workflow and PSMA PET/MR protocol for prostate cancer evaluation: Initial experience and results
    Queiroz, M. A.
    Ferraro, D. A.
    Buchpiguel, C. A.
    Cerri, G. G.
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2019, 203 (8-9): : 662 - 669
  • [46] NEMA NU 4-2008 performance evaluation and MR compatibility tests of an APD-based small animal PET-insert for simultaneous PET/MR imaging
    Disselhorst, Jonathan A.
    Newport, Danny F.
    Schmid, Andreas M.
    Schmidt, Fabian P.
    Parl, Christoph
    Liu, Chih-Chieh
    Pichler, Bernd J.
    Mannheim, Julia G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (04)
  • [47] Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System
    Lassen, Martin L.
    Muzik, Otto
    Beyer, Thomas
    Hacker, Marcus
    Ladefoged, Claes Nohr
    Cal-Gonzalez, Jacobo
    Wadsak, Wolfgang
    Rausch, Ivo
    Langer, Oliver
    Bauer, Martin
    FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [48] An Optimized System for Interventional Magnetic Resonance Imaging-Guided Stereotactic Surgery: Preliminary Evaluation of Targeting Accuracy
    Larson, Paul S.
    Starr, Philip A.
    Bates, Geoffrey
    Tansey, Lisa
    Richardson, R. Mark
    Martin, Alastair J.
    NEUROSURGERY, 2012, 70 : 95 - 103
  • [49] MR-guided percutaneous ethanol ablation of liver tissue in a .2-T open MR system: Preliminary study in porcine model
    Lu, DSK
    Sinha, S
    Lucas, J
    Farahani, K
    Lufkin, R
    Lewin, K
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 303 - 308
  • [50] Preoperative evaluation of bile duct cancer: MRI combined with MR cholangiopancreatography versus MDCT with direct cholangiography
    Park, Hee Sun
    Lee, Jeong Min
    Choi, Jin-Young
    Lee, Min Woo
    Kim, Hyuk Jung
    Han, Joon Koo
    Choi, Byung Ihn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 396 - 405