Preliminary Evaluation of a Combined MicroPET®-MR System

被引:18
|
作者
Hawkes, R. C. [1 ]
Fryer, T. D. [1 ]
Siegel, S. [3 ]
Ansorge, R. E. [2 ]
Carpenter, T. A. [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[3] Preclin Solut, Siemens Mol Imaging, Knoxville, TN 37932 USA
基金
英国工程与自然科学研究理事会;
关键词
PET; MRI; Positron emission tomography; Magnetic resonance imaging; Multimodality Imaging; PET SCANNER; PERFORMANCE EVALUATION; POSITRON TOMOGRAPH; SENSITIVITY; COILS;
D O I
10.1177/153303461000900106
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
There are many motivations for adding simultaneously acquired MR images to PET scanning. The most straight forward are, superior registration of MR and PET images, the addition of morphological detail when there is non-rigid motion and for pre-clinical studies simultaneous imaging could lead to a significant reduction in the time that animals are required to be anesthetised. In addition simultaneous MR has the potential to provide accurate motion correction for PET image reconstruction. For functional imaging simultaneous acquisition is required to assess the subject in the same physiological state, such as acute stroke studies. The elimination of the additional radiation associated with combining CT with PET, by providing anatomic detail with MR, would be a crucial advantage for cancer screening. Combining the two instruments necessitates some engineering tradeoffs, especially associated with the use of the highly developed photomultiplier tube (PMT) used for light amplification, because of its incompatibility with strong magnetic fields. Our approach is to provide a split in the magnet and gradients to locate the magnetic sensitive components, the PMTs, in regions of low magnetic field, leaving only the essential PET components, the scintillator blocks, in the strong magnetic field region. The crystals are coupled to the PMTs by extending the optical fibres. A further advantage accrues by moving the PET electronics out of the region seen by the MR radio-frequency (RF) and gradient coils as electromagnetic interference effects between the PET and MR systems, which could cause artefacts in either modality, are eliminated. Here we describe a preliminary evaluation of the system, which is essentially a microPET Focus-120 located in a 1 T split magnet, and compare its performance to previous microPET instruments.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [21] Combined Structural MR and Diffusion Tensor Imaging Classify the Presence of Alzheimer's Disease With the Same Performance as MR Combined With Amyloid Positron Emission Tomography: A Data Integration Approach
    Agostinho, Daniel
    Caramelo, Francisco
    Moreira, Ana Paula
    Santana, Isabel
    Abrunhosa, Antero
    Castelo-Branco, Miguel
    FRONTIERS IN NEUROSCIENCE, 2022, 15
  • [22] Wrist ligament tears: Evaluation of MRI and combined MDCT and MR arthrography
    Moser, Thomas
    Dosch, Jean-Claude
    Moussaoui, Akli
    Dietemann, Jean-Louis
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1278 - 1286
  • [23] MR-guided data framing for PET motion correction in simultaneous MR-PET: A preliminary evaluation
    Ullisch, M. G.
    Scheins, J.
    Weirich, C.
    Kops, E. Rota
    Celik, A.
    Tellmann, L.
    Stoecker, T.
    Herzog, H.
    Shah, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 67 - 69
  • [24] Performance evaluation of microPET: A high-resolution lutetium oxyorthosilicate PET scanner for animal imaging
    Chatziioannou, AF
    Cherry, SR
    Shao, YP
    Silverman, RW
    Meadors, K
    Farquhar, TH
    Pedarsani, M
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (07) : 1164 - 1175
  • [25] Combined PET/MR: A Technology Becomes Mature
    Wehrl, Hans F.
    Sauter, Alexander W.
    Divine, Mathew R.
    Pichler, Bernd J.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (02) : 165 - 168
  • [26] Fetal MR in the evaluation of pulmonary and digestive system pathology
    Martin C.
    Darnell A.
    Escofet C.
    Duran C.
    Pérez V.
    Insights into Imaging, 2012, 3 (3) : 277 - 293
  • [27] State of the Art MR Imaging for Lung Cancer TNM Stage Evaluation
    Ohno, Yoshiharu
    Ozawa, Yoshiyuki
    Koyama, Hisanobu
    Yoshikawa, Takeshi
    Takenaka, Daisuke
    Nagata, Hiroyuki
    Ueda, Takahiro
    Ikeda, Hirotaka
    Toyama, Hiroshi
    CANCERS, 2023, 15 (03)
  • [28] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322
  • [29] Non-contrast MR dacryocystography for the evaluation of epiphora and recurrent dacryocystitis: A preliminary study
    Ce, Maurizio
    Grimaldi, Elena
    Toto-Brocchi, Marco
    Martinenghi, Carlo
    Oliva, Giancarlo
    Felisaz, Paolo Florent
    Schiavo, Paolo
    Lunardi, Giuseppe
    Cellina, Michaela
    NEURORADIOLOGY JOURNAL, 2023, 36 (04) : 397 - 403
  • [30] Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET
    Yang, Xiaofeng
    Fei, Baowei
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2013, 20 (06) : 1037 - 1045