Preliminary Evaluation of a Combined MicroPET®-MR System

被引:18
|
作者
Hawkes, R. C. [1 ]
Fryer, T. D. [1 ]
Siegel, S. [3 ]
Ansorge, R. E. [2 ]
Carpenter, T. A. [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[3] Preclin Solut, Siemens Mol Imaging, Knoxville, TN 37932 USA
基金
英国工程与自然科学研究理事会;
关键词
PET; MRI; Positron emission tomography; Magnetic resonance imaging; Multimodality Imaging; PET SCANNER; PERFORMANCE EVALUATION; POSITRON TOMOGRAPH; SENSITIVITY; COILS;
D O I
10.1177/153303461000900106
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
There are many motivations for adding simultaneously acquired MR images to PET scanning. The most straight forward are, superior registration of MR and PET images, the addition of morphological detail when there is non-rigid motion and for pre-clinical studies simultaneous imaging could lead to a significant reduction in the time that animals are required to be anesthetised. In addition simultaneous MR has the potential to provide accurate motion correction for PET image reconstruction. For functional imaging simultaneous acquisition is required to assess the subject in the same physiological state, such as acute stroke studies. The elimination of the additional radiation associated with combining CT with PET, by providing anatomic detail with MR, would be a crucial advantage for cancer screening. Combining the two instruments necessitates some engineering tradeoffs, especially associated with the use of the highly developed photomultiplier tube (PMT) used for light amplification, because of its incompatibility with strong magnetic fields. Our approach is to provide a split in the magnet and gradients to locate the magnetic sensitive components, the PMTs, in regions of low magnetic field, leaving only the essential PET components, the scintillator blocks, in the strong magnetic field region. The crystals are coupled to the PMTs by extending the optical fibres. A further advantage accrues by moving the PET electronics out of the region seen by the MR radio-frequency (RF) and gradient coils as electromagnetic interference effects between the PET and MR systems, which could cause artefacts in either modality, are eliminated. Here we describe a preliminary evaluation of the system, which is essentially a microPET Focus-120 located in a 1 T split magnet, and compare its performance to previous microPET instruments.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [1] Development of a combined microPET®-MR system
    Lucas, A. J.
    Hawkes, R. C.
    Ansorge, R. E.
    Williams, G. B.
    Nutt, R. E.
    Clark, J. C.
    Fryer, T. A.
    Carpenter, T. A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (04) : 337 - 341
  • [2] Performance evaluation of the microPET system
    Gao Fei
    Liu Hua-Feng
    Shi Peng-Cheng
    ACTA PHYSICA SINICA, 2007, 56 (07) : 4229 - 4234
  • [3] Evaluation of a multiple system atrophy model in rats using multitracer microPET
    Yoon, Hyung Ho
    Lee, Chong Sik
    Hong, Seok Ho
    Min, Joongkee
    Kim, Yong Hwan
    Hwang, Onyou
    Jeon, Sang Ryong
    ACTA NEUROCHIRURGICA, 2012, 154 (05) : 935 - 940
  • [4] Combined PET/MR Imaging - Technology and Applications
    Wehrl, H. F.
    Sauter, A. W.
    Judenhofer, M. S.
    Pichler, B. J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (01) : 5 - 20
  • [5] Longitudinal evaluation of five nasopharyngeal carcinoma animal models on the microPET/MR platform
    Shi, Jingjing
    Xue, Zhichao
    Tan, Kel Vin
    Yuan, Hui
    Tsang, Anna Chi Man
    Tsao, Sai Wah
    Khong, Pek-Lan
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (05) : 1497 - 1507
  • [6] Combined PET/MR systems: an overview and comparison of currently available options
    Herzog, H.
    Van Den Hoff, J.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 56 (03) : 247 - 267
  • [7] An integrated MR/PET system: prospective applications
    Schlemmer, Heinz-Peter
    Pichler, Bernd J.
    Krieg, Robert
    Heiss, Wolf-Dieter
    ABDOMINAL IMAGING, 2009, 34 (06): : 668 - 674
  • [8] An integrated MR/PET system: prospective applications
    Heinz-Peter Schlemmer
    Bernd J. Pichler
    Robert Krieg
    Wolf-Dieter Heiss
    Abdominal Imaging, 2009, 34 : 668 - 674
  • [9] Performance evaluation of the microPET® -: FOCUS-F120
    Laforest, Richard
    Longford, Desmond
    Siegel, Stefan
    Newport, Danny F.
    Yap, Jeffrey
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 42 - 49
  • [10] Evaluation of a multiple system atrophy model in rats using multitracer microPET
    Hyung Ho Yoon
    Chong Sik Lee
    Seok Ho Hong
    Joongkee Min
    Yong Hwan Kim
    Onyou Hwang
    Sang Ryong Jeon
    Acta Neurochirurgica, 2012, 154 : 935 - 940