Molecularly imprinted solid-phase extraction combined with molecularly imprinted polymer-sensor: a diagnostic tool applicable to creatine deficiency syndrome

被引:12
作者
Sharma, Piyush Sindhu [1 ]
Lakshmi, Dhana [1 ]
Prasad, Bhim Bali [1 ]
机构
[1] Banaras Hindu Univ, Dept Chem, Analyt Div, Varanasi 221005, Uttar Pradesh, India
关键词
molecularly imprinted polymer; creatine; molecularly imprinted polymer-modified HMDE sensor; molecularly imprinted solid-phase extraction; blood serum;
D O I
10.1002/bmc.842
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Primary creatine deficiency syndromes (CDS) are a new group of disorders caused by guanidinoacetate methyltransferase (GAMT) deficiency, which affects endogenous creatine biosynthesis with depletion of body creatine. A deficiency in creatine can be corrected by treatment with oral creatine supplementation and this necessitates a simple and sensitive screening method for early detection of creatine in dilute physiologic fluids. In this work an artificial receptor, molecularly imprinted polymer (MIP), for creatine was used both as a material for solid-phase extraction (SPE) and as a sensing element in a voltammetric sensor. Using the combination of molecularly imprinted solid-phase extraction (MISPE) with a complementary MIP sensor, the minimum detectable amount was found to be 0.0015 ng mL(-1) (RSD = 1.3%, S/N = 3). The MISPE-MIP sensor combination provided up to 60-fold preconcentration, which was more than sufficient for achieving the required quantification limit 50 ng mL(-1) (or 0.0025 ng mL(-1) after 2 x 10(4)-fold dilution) for creatine in human blood serum. Copyright 0 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:976 / 986
页数:11
相关论文
共 46 条
[1]   A highly selective solid phase extraction sorbent for pre-concentration of sameridine made by molecular imprinting [J].
Andersson, LI ;
Paprica, A ;
Arvidsson, T .
CHROMATOGRAPHIA, 1997, 46 (1-2) :57-62
[2]  
BEYER C, 1993, CLIN CHEM, V39, P1743
[3]  
Beyer C, 1996, CLIN CHEM, V42, P313
[4]   Analysis of guanidinoacetate and creatine by isotope dilution electrospray tandem mass spectrometry [J].
Bodamer, OA ;
Bloesch, SM ;
Gregg, AR ;
Stockler-Ipsiroglu, S ;
O'Brien, WE .
CLINICA CHIMICA ACTA, 2001, 308 (1-2) :173-178
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF GUANIDINO COMPOUNDS BY AUTOMATED PRECOLUMN FLUORESCENCE DERIVATIZATION [J].
BOPPANA, VK ;
RHODES, GR .
JOURNAL OF CHROMATOGRAPHY, 1990, 506 :279-288
[6]  
BORSOOK H, 1947, J BIOL CHEM, V168, P493
[7]   Analysis of creatine and creatinine in urine by capillary electrophoresis [J].
Burke, DG ;
MacLean, PG ;
Walker, RA ;
Dewar, PJ ;
Smith-Palmer, T .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02) :479-485
[8]   THE OPTICAL RESOLUTION OF AROMATIC AMINO-ACIDS ON PAPER CHROMATOGRAMS [J].
DALGLIESH, CE .
JOURNAL OF THE CHEMICAL SOCIETY, 1952, (OCT) :3940-3942
[9]   Evaluation of methods aimed at complete removal of template from molecularly imprinted polymers [J].
Ellwanger, A ;
Berggren, C ;
Bayoudh, S ;
Crecenzi, C ;
Karlsson, L ;
Owens, PK ;
Ensing, K ;
Cormack, P ;
Sherrington, D ;
Sellergren, B .
ANALYST, 2001, 126 (06) :784-792
[10]   Stable isotope dilution method for the determination of guanidinoacetic acid by gas chromatography/mass spectrometry [J].
Fingerhut, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) :717-722