Enhanced definition PET for cardiac imaging

被引:38
|
作者
Le Meunier, Ludovic [1 ,2 ,4 ]
Slomka, Piotr J. [1 ,2 ,3 ]
Dey, Damini [1 ,2 ,3 ]
Ramesh, Amit [3 ]
Thomson, Louis E. J. [1 ,2 ]
Hayes, Sean W. [1 ,2 ]
Friedman, John D. [1 ,2 ]
Cheng, Victor [1 ,2 ]
Germano, Guido [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Los Angeles, CA 90095 USA
[4] Siemens Healthcare Mol Imaging, Knoxville, TN USA
关键词
High definition; PET/CT imaging; myocardial viability; F-18-FDG; Rb-82; RECONSTRUCTION; SUPERRESOLUTION; QUANTIFICATION; FLIGHT;
D O I
10.1007/s12350-010-9193-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to determine in phantom and cardiac clinical studies the impact of a new high-resolution PET image reconstruction. A phantom with cardiac insert filled with F-18, 14 F-18-FDG viability studies and 15 Rb-82 perfusion studies were acquired on a Siemens Biograph-64 (4-ring). The data were reconstructed with 2D- and 3D-attenuation weighted ordered subsets expectation maximization (AWOSEM), and high-definition reconstruction (HD center dot PET). We calculated wall/cavity contrast, contrast-to-noise ratio (CNR), wall thickness, motion/thickening and ejection fraction. In the phantom study, we found an increase in defect size (up to 26%), contrast (up to 48%) and CNR (1.9) with HD center dot PET as compared to standard techniques. The contrast increased on HD center dot PET images compared to 2D- and 3D-AWOSEM for viability (14.0% +/- A 4.8%) and perfusion studies (7.3% +/- A 4.3%) (P < .05). Average CNR increased with HD center dot PET by 79.4% +/- A 17.1% and 68.8% +/- A 3.0% in viability and perfusion studies respectively (all P < .05). Average wall thickness with HD center dot PET decreased in the phantom study by 1.3 +/- A 0.3 mm and the viability studies by 1.9 +/- A 0.7 mm but not in the perfusion studies. The functional measurements were not significantly different for any techniques. We demonstrated both in phantom and patient cardiac studies that HD center dot PET improves image contrast, defect definition, and CNR.
引用
收藏
页码:414 / 426
页数:13
相关论文
共 50 条
  • [41] Proceedings of the cardiac PET summit meeting 12 may 2014: Cardiac PET and SPECT instrumentation
    Garcia, Ernest V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (03) : 563 - 570
  • [42] Cardiac imaging with high frame rate contrast enhanced ultrasound: in-vivo demonstration
    Toulemonde, M.
    Li, Y.
    Lin, S.
    Tang, M. X.
    Butler, M.
    Sboros, V.
    Eckersley, R.
    Duncan, W. C.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [43] Molecular imaging of atherosclerosis with integrated PET imaging
    Hammad, Basma
    Evans, Nicholas R.
    Rudd, James H. F.
    Tawakol, Ahmed
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 938 - 943
  • [44] Cardiovascular Imaging with PET, CT, and MR Imaging
    Takalkar, Amol
    Chen, Wengen
    Desjardins, Benoit
    Alavi, Abass
    Torigian, Drew A.
    PET CLINICS, 2008, 3 (03) : 411 - +
  • [45] Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision
    Xie, Huidong
    Guo, Liang
    Velo, Alexandre
    Liu, Zhao
    Liu, Qiong
    Guo, Xueqi
    Zhou, Bo
    Chen, Xiongchao
    Tsai, Yu-Jung
    Miao, Tianshun
    Xia, Menghua
    Liu, Yi-Hwa
    Armstrong, Ian S.
    Wang, Ge
    Carson, Richard E.
    Sinusas, Albert J.
    Liu, Chi
    MEDICAL IMAGE ANALYSIS, 2025, 100
  • [46] Comparison among Reconstruction Algorithms for Quantitative Analysis of 11C-Acetate Cardiac PET Imaging
    Shi, Ximin
    Li, Nan
    Ding, Haiyan
    Dang, Yonghong
    Hu, Guilan
    Liu, Shuai
    Cui, Jie
    Zhang, Yue
    Li, Fang
    Zhang, Hui
    Huo, Li
    CONTRAST MEDIA & MOLECULAR IMAGING, 2018,
  • [47] Assessment of myocardial viability using echocardiographic strain imaging in patients with ST-elevation myocardial infarction: comparison with cardiac PET imaging
    Ambudhar Sharma
    Ashwani Sood
    Bhagwant Rai Mittal
    Rajesh Vijayvergiya
    Journal of Echocardiography, 2020, 18 : 240 - 252
  • [48] Assessment of myocardial viability using echocardiographic strain imaging in patients with ST-elevation myocardial infarction: comparison with cardiac PET imaging
    Sharma, Ambudhar
    Sood, Ashwani
    Mittal, Bhagwant Rai
    Vijayvergiya, Rajesh
    JOURNAL OF ECHOCARDIOGRAPHY, 2020, 18 (04) : 240 - 252
  • [49] Is It Possible to Predict Heart Rate and Range during Enhanced Cardiac CT Scan from Previous Non-enhanced Cardiac CT?
    Horiguchi, Jun
    Yamamoto, Hideya
    Arie, Ryuichi
    Kiguchi, Masao
    Fujioka, Chikako
    Ohtaki, Megu
    Kihara, Yasuki
    Awai, Kazuo
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (04) : 688 - 693
  • [50] Parametric Myocardial Perfusion PET Imaging using Physiological Clustering
    Mohy-ud-Din, Hassan
    Karakatsanis, Nikolaos A.
    Lodge, Martin A.
    Tang, Jing
    Rahmim, Arman
    MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2014, 9038