Enhanced definition PET for cardiac imaging

被引:38
|
作者
Le Meunier, Ludovic [1 ,2 ,4 ]
Slomka, Piotr J. [1 ,2 ,3 ]
Dey, Damini [1 ,2 ,3 ]
Ramesh, Amit [3 ]
Thomson, Louis E. J. [1 ,2 ]
Hayes, Sean W. [1 ,2 ]
Friedman, John D. [1 ,2 ]
Cheng, Victor [1 ,2 ]
Germano, Guido [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Los Angeles, CA 90095 USA
[4] Siemens Healthcare Mol Imaging, Knoxville, TN USA
关键词
High definition; PET/CT imaging; myocardial viability; F-18-FDG; Rb-82; RECONSTRUCTION; SUPERRESOLUTION; QUANTIFICATION; FLIGHT;
D O I
10.1007/s12350-010-9193-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to determine in phantom and cardiac clinical studies the impact of a new high-resolution PET image reconstruction. A phantom with cardiac insert filled with F-18, 14 F-18-FDG viability studies and 15 Rb-82 perfusion studies were acquired on a Siemens Biograph-64 (4-ring). The data were reconstructed with 2D- and 3D-attenuation weighted ordered subsets expectation maximization (AWOSEM), and high-definition reconstruction (HD center dot PET). We calculated wall/cavity contrast, contrast-to-noise ratio (CNR), wall thickness, motion/thickening and ejection fraction. In the phantom study, we found an increase in defect size (up to 26%), contrast (up to 48%) and CNR (1.9) with HD center dot PET as compared to standard techniques. The contrast increased on HD center dot PET images compared to 2D- and 3D-AWOSEM for viability (14.0% +/- A 4.8%) and perfusion studies (7.3% +/- A 4.3%) (P < .05). Average CNR increased with HD center dot PET by 79.4% +/- A 17.1% and 68.8% +/- A 3.0% in viability and perfusion studies respectively (all P < .05). Average wall thickness with HD center dot PET decreased in the phantom study by 1.3 +/- A 0.3 mm and the viability studies by 1.9 +/- A 0.7 mm but not in the perfusion studies. The functional measurements were not significantly different for any techniques. We demonstrated both in phantom and patient cardiac studies that HD center dot PET improves image contrast, defect definition, and CNR.
引用
收藏
页码:414 / 426
页数:13
相关论文
共 50 条
  • [21] Value of PET ECG gating in a cross-validation study of cardiac function assessment by PET/MR imaging
    Asiares, Alberto Villagran
    Vitadello, Teresa
    Bogdanovic, Borjana
    Solari, Esteban Lucas
    McIntosh, Lachlan
    Schachoff, Sylvia
    Ibrahim, Tareq
    Nekolla, Stephan G.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (03) : 1050 - 1060
  • [22] Imaging moving heart structures with PET
    Slomka, Piotr J.
    Pan, Tinsu
    Germano, Guido
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (03) : 486 - 490
  • [23] Enhancing Cardiac PET by Motion Correction Techniques
    Rubeaux, Mathieu
    Doris, Mhairi K.
    Alessio, Adam
    Slomka, Piotr J.
    CURRENT CARDIOLOGY REPORTS, 2017, 19 (02)
  • [24] Imaging Techniques for Cardiac Function
    Panis, Vasileios
    Donal, Erwan
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [25] The response of FDG uptake to immunosuppressive treatment on FDG PET/CT imaging for cardiac sarcoidosis
    Ahmadian, Azadeh
    Pawar, Sumeet
    Govender, Praveen
    Berman, Jeffrey
    Ruberg, Frederick L.
    Miller, Edward J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (02) : 413 - 424
  • [26] Dual respiratory and cardiac motion estimation in PET imaging: Methods design and quantitative evaluation
    Feng, Tao
    Wang, Jizhe
    Tsui, Benjamin M. W.
    MEDICAL PHYSICS, 2018, 45 (04) : 1481 - 1490
  • [27] The response of FDG uptake to immunosuppressive treatment on FDG PET/CT imaging for cardiac sarcoidosis
    Azadeh Ahmadian
    Sumeet Pawar
    Praveen Govender
    Jeffrey Berman
    Frederick L. Ruberg
    Edward J. Miller
    Journal of Nuclear Cardiology, 2017, 24 : 413 - 424
  • [28] MR-based motion correction for cardiac PET parametric imaging: a simulation study
    Guo, Rong
    Petibon, Yoann
    Ma, Yixin
    El Fakhri, Georges
    Ying, Kui
    Ouyang, Jinsong
    EJNMMI PHYSICS, 2018, 5
  • [29] Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET
    Karakatsanis, Nicolas A.
    Zhou, Yun
    Lodge, Martin A.
    Casey, Michael E.
    Wahl, Richard L.
    Zaidi, Habib
    Rahmim, Arman
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22) : 8643 - 8673
  • [30] Clinical evaluation of deep learning-enhanced lymphoma pet imaging with accelerated acquisition
    Li, Xu
    Pan, Boyang
    Chen, Congxia
    Yan, Dongyue
    Pan, Zhenglin
    Feng, Tao
    Liu, Hui
    Gong, Nan-Jie
    Liu, Fugeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):