Enhanced definition PET for cardiac imaging

被引:37
作者
Le Meunier, Ludovic [1 ,2 ,4 ]
Slomka, Piotr J. [1 ,2 ,3 ]
Dey, Damini [1 ,2 ,3 ]
Ramesh, Amit [3 ]
Thomson, Louis E. J. [1 ,2 ]
Hayes, Sean W. [1 ,2 ]
Friedman, John D. [1 ,2 ]
Cheng, Victor [1 ,2 ]
Germano, Guido [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Los Angeles, CA 90095 USA
[4] Siemens Healthcare Mol Imaging, Knoxville, TN USA
关键词
High definition; PET/CT imaging; myocardial viability; F-18-FDG; Rb-82; RECONSTRUCTION; SUPERRESOLUTION; QUANTIFICATION; FLIGHT;
D O I
10.1007/s12350-010-9193-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to determine in phantom and cardiac clinical studies the impact of a new high-resolution PET image reconstruction. A phantom with cardiac insert filled with F-18, 14 F-18-FDG viability studies and 15 Rb-82 perfusion studies were acquired on a Siemens Biograph-64 (4-ring). The data were reconstructed with 2D- and 3D-attenuation weighted ordered subsets expectation maximization (AWOSEM), and high-definition reconstruction (HD center dot PET). We calculated wall/cavity contrast, contrast-to-noise ratio (CNR), wall thickness, motion/thickening and ejection fraction. In the phantom study, we found an increase in defect size (up to 26%), contrast (up to 48%) and CNR (1.9) with HD center dot PET as compared to standard techniques. The contrast increased on HD center dot PET images compared to 2D- and 3D-AWOSEM for viability (14.0% +/- A 4.8%) and perfusion studies (7.3% +/- A 4.3%) (P < .05). Average CNR increased with HD center dot PET by 79.4% +/- A 17.1% and 68.8% +/- A 3.0% in viability and perfusion studies respectively (all P < .05). Average wall thickness with HD center dot PET decreased in the phantom study by 1.3 +/- A 0.3 mm and the viability studies by 1.9 +/- A 0.7 mm but not in the perfusion studies. The functional measurements were not significantly different for any techniques. We demonstrated both in phantom and patient cardiac studies that HD center dot PET improves image contrast, defect definition, and CNR.
引用
收藏
页码:414 / 426
页数:13
相关论文
共 20 条
[1]  
Cerqueira ManuelD., 2002, STANDARDIZED MYOCARD, P539
[2]   Comparison between two super-resolution implementations in PET imaging [J].
Chang, Guoping ;
Pan, Tinsu ;
Qiao, Feng ;
Clark, John W., Jr. ;
Mawlawi, Osama R. .
MEDICAL PHYSICS, 2009, 36 (04) :1370-1383
[3]  
CONTI M, 2006, IEEE T NUCL SCI, P53
[4]   Resolution recovery in PET during AWOSEM reconstruction: A performance evaluation study [J].
De Bernardi, Elisabetta ;
Mazzoli, Marco ;
Zito, Felicia ;
Baselli, Giuseppe .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) :1626-1638
[5]   Clinical myocardial perfusion PET/CT [J].
Di Carli, Marcelo F. ;
Dorbala, Sharmila ;
Meserve, Jolene ;
El Fakhri, Georges ;
Sitek, Arkadiusz ;
Moore, Stephen C. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) :783-793
[6]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308
[7]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[8]   A comparison of the imaging properties of a 3-and 4-ring biograph PET scanner using a novel extended NEMA phantom [J].
Jonsson, C. ;
Odh, R. ;
Schnell, P-O. ;
Larsson, S. A. .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :2865-2867
[9]   Impact of Time-of-Flight on PET Tumor Detection [J].
Kadrmas, Dan J. ;
Casey, Michael E. ;
Conti, Maurizio ;
Jakoby, Bjoern W. ;
Lois, Cristina ;
Townsend, David W. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) :1315-1323
[10]   Super-resolution in PET imaging [J].
Kennedy, JA ;
Israel, O ;
Frenkel, A ;
Bar-Shalom, R ;
Azhari, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (02) :137-147