Norian SRS versus functional treatment in redisplaced distal radial fractures: A randomized study in 20 patients

被引:30
作者
Kopylov, P [1 ]
Adalberth, K
Jonsson, K
Aspenberg, P
机构
[1] Univ Lund Hosp, Dept Orthoped, Hand Unit, SE-22185 Lund, Sweden
[2] Fac Hlth Sci, Dept Orthoped, Linkoping, Sweden
[3] Lund Univ, Dept Diagnost Radiol, Lund, Sweden
关键词
D O I
10.1054/jhsb.2002.0799
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the use of Norian SRS, an injectable calcium phosphate bone cement, with functional treatment of redisplaced distal radial fractures in a prospective randomized study of 20 patients. The redisplaced fractures were either rereduced and stabilized by Norian SRS, or the displaced position was accepted and was not rereduced. All wrists were immobilized in a short-arm dorsal splint for 1 week, followed by a removable splint for another 3 weeks. The chosen primary effect variable was grip strength at 7 weeks, and this did not differ between the two treatment groups. The clinical results at 6 months in both groups were similar. We conclude that aggressive treatment of redisplaced fractures of the distal radius may be unnecessary in most women aged 50 years or more.
引用
收藏
页码:538 / 541
页数:4
相关论文
共 14 条
[1]   COMPLICATIONS OF COLLES FRACTURES [J].
COONEY, WP ;
DOBYNS, JH ;
LINSCHEID, RL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (04) :613-619
[3]  
Fernandez DL, 1996, FRACTURES DISTAL RAD
[4]  
FRYKMAN G, 1967, ACTA ORTHOPAEDICA S, V108
[5]   Repair of five distal radius fractures with an investigational cancellous bone cement: A preliminary report [J].
Jupiter, JB ;
Winters, S ;
Sigman, S ;
Lowe, C ;
Pappas, C ;
Ladd, AL ;
Van Wagoner, M ;
Smith, ST .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (02) :110-116
[6]   FRACTURES OF THE DISTAL END OF THE RADIUS IN YOUNG-ADULTS - A 30-YEAR FOLLOW-UP [J].
KOPYLOV, P ;
JOHNELL, O ;
REDLUNDJOHNELL, I ;
BENGNER, U .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (01) :45-49
[7]   Norian SRS versus external fixation in redisplaced distal radial fractures - A randomized study in 40 patients [J].
Kopylov, P ;
Runnqvist, K ;
Jonsson, K ;
Aspenberg, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (01) :1-5
[8]  
MACAULIFFE TB, 1987, J BONE JOINT SURG BR, V69, P727
[9]  
MACQUEEN MM, 1996, J BONE JOINT SURG BR, V78, P404
[10]   Treatment of fractures of the distal radius with a remodellable bone cement - A prospective, randomised study using Norian SRS [J].
Sanchez-Sotelo, J ;
Munuera, L ;
Madero, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06) :856-863