Evaluation of the efficacy and reproducibility of cholangiopancreatography by magnetic resonance for detecting biliary complications following orthotopic liver transplantation

被引:7
作者
Linhares, Marcelo Moura
de Souza Coelho, Rafael Darahen [2 ]
Szejnfeld, Jacob [2 ]
Goldman, Susan Menasce [2 ]
Gonzalez, Adriano Miziara
Szejnfeld, Denis [2 ]
Matos, Carla [3 ]
Salzedas, Alcides [1 ]
Goldenberg, Alberto
Lopes-Filho, Gaspar Jesus [1 ]
Matos, Delcio [4 ]
机构
[1] Univ Fed Sao Paulo, Dept Surg, Div Liver Transplantat, Sao Paulo, Brazil
[2] Univ Fed Sao Paulo, Dept Image Diagnost, Sao Paulo, Brazil
[3] Univ Fed Sao Paulo, Dept Med, Sao Paulo, Brazil
[4] Univ Fed Sao Paulo, Div Surg Gastroenterol, Dept Surg, Sao Paulo, Brazil
关键词
Liver Transplantation; Magnetic Resonance Imaging; Bile Ducts; Cholangiography; ENHANCED MR CHOLANGIOGRAPHY; BILE-DUCT LEAKS; TRACT COMPLICATIONS; TRISODIUM TESLASCAN; STRICTURES; MANAGEMENT; DIAGNOSIS; IMPACT; ERCP;
D O I
10.1590/S0102-86502010000300006
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the accuracy and reproducibility of magnetic resonance cholangiopancreatography (MRCP) in the detection of biliary complications in liver transplanted patients. Methods: A study was conducted, with blinded review of 28 MRCP exams of 24 patients submitted to liver transplantation. The images were reviewed by two independent observers, at two different moments, regarding the degree of biliary tree visualization and the presence or absence of biliary complications. The MRCP results were compared, when negative, to at least 3 months of clinical and biochemical follow-up, and when positive, to the findings at surgery or endoscopic retrograde cholangiopancreatography (ERCP). Results: The degree of intrahepatic biliary tree visualization was considered good or excellent in 78.6% and 82.1% of the exams by the two observers and visualization of the donor duct, recipient duct and biliary anastomosis was considered good or excellent in 100% of the exams, by both observers. Six biliary complications were detected (21.4%), all of them anastomotic strictures. Intra and interobserver agreement were substantial or almost perfect (kappa k values of 0.611 to 0.804) for the visualization of the biliary tree and almost perfect (k values of 0.900 to 1.000) for the detection of biliary complications. MRCP achieved 100% sensitivity, 95.45% specificity, 85.7% positive predictive value and 100% negative predictive value for the detection of biliary complications. Conclusions: MRCP is an accurate examination for the detection of biliary complications after orthotopic liver transplantation and it is a highly reproducible method in the evaluation of the biliary tree of liver transplanted patients.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 50 条
  • [31] Biliary complications following liver transplantation
    Gursimran Kochhar
    Jose Mari Parungao
    Ibrahim A Hanouneh
    Mansour A Parsi
    [J]. World Journal of Gastroenterology, 2013, 19 (19) : 2841 - 2846
  • [32] Biliary Complications Following Liver Transplantation
    Walid S. Ayoub
    Carlos O. Esquivel
    Paul Martin
    [J]. Digestive Diseases and Sciences, 2010, 55 : 1540 - 1546
  • [33] Application of cholecystic duct plasty in the prevention of biliary complications following orthotopic liver transplantation
    Cui, Song-ping
    Lyu, Shao-cheng
    Wang, Jing
    Chen, Qing
    Huang, Jin-can
    Wang, Han-xuan
    He, Qiang
    Lang, Ren
    [J]. FRONTIERS IN SURGERY, 2023, 10
  • [34] The effect of smoking on biliary complications following liver transplantation
    Mathur, Amit K.
    Ranney, David N.
    Patel, Shaun P.
    Lee, Dennis S.
    Bednar, Filip
    Lynch, Raymond J.
    Welling, Theodore H.
    Englesbe, Michael J.
    [J]. TRANSPLANT INTERNATIONAL, 2011, 24 (01) : 58 - 66
  • [35] The radiological management of biliary complications following liver transplantation
    Rieber, A
    Brambs, HJ
    Lauchart, W
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 19 (04) : 242 - 247
  • [38] A Review on the Management of Biliary Complications after Orthotopic Liver Transplantation
    Moy, Brian T.
    Birk, John W.
    [J]. JOURNAL OF CLINICAL AND TRANSLATIONAL HEPATOLOGY, 2019, 7 (01) : 61 - 71
  • [39] The role of MR cholangiography in the detection of biliary complications after orthotopic liver transplantation
    Edyta, Maj
    Andrzej, Cieszanowski
    Marek, Golebiowski
    Bartosz, Cieslak
    Krzysztof, Zieniewicz
    Marek, Krawczyk
    Olgierd, Rowinski
    [J]. POLISH JOURNAL OF RADIOLOGY, 2007, 72 (02) : 25 - 31
  • [40] Covered Metal Stents for the Treatment of Biliary Complications after Orthotopic Liver Transplantation
    Garcia-Pajares, F.
    Sanchez-Antolin, G.
    Pelayo, S. L.
    Gomez de la Cuesta, S.
    Herranz Bachiller, M. T.
    Perez-Miranda, M.
    de la Serna, C.
    Vallecillo Sande, M. A.
    Alcaide, N.
    Llames, R. V.
    Pacheco, D.
    Caro-Paton, A.
    [J]. TRANSPLANTATION PROCEEDINGS, 2010, 42 (08) : 2966 - 2969