Multicenter evaluation of the Paragon CZE™ 2000 capillary zone electrophoresis system for serum protein electrophoresis and monoclonal component typing

被引:0
|
作者
Bienvenu, J
Graziani, MS
Arpin, F
Bernon, H
Blessum, C
Marchetti, C
Righetti, G
Somenzini, M
Verga, G
Aguzzi, F [1 ]
机构
[1] Osped Stradella, Lab Anal, I-27049 Stradella, Italy
[2] Ctr Hosp Lyon Sud, Immunol Lab, F-69495 Pierre Benite, France
[3] Osped Civile Maggiore, Chim Clin & Ematol Lab, I-37126 Verona, Italy
[4] Beckman Instruments Inc, Brea, CA 92621 USA
[5] Beckman Analyt SPA, I-20060 Cassina De Pecchi, Italy
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Serum protein electrophoresis and typing of monoclonal components (MCs) are routine but time-consuming and technically demanding assays. We evaluated capillary electrophoresis (Paragon CZE(TM) 2000) for automation of the two assays. CZE and cellulose acetate electrophoresis gave similar data on 794 samples. Within-run and between-run CVs were <2% for albumin and gamma-globulins and 4-7% for alpha(1)-, alpha(2)-, and beta-globulins. Bilirubin, hemoglobin, triglycerides, and fibrinogen were found not to interfere. No carryover by capillaries was detected. The detection limit for MC was <0.5 g/L. MC assessment by immunosubtraction on 403 samples identified the monoclonal type in all samples with peak concentrations >10 g/L; only 50% of MCs that could not be quantified by densitometric scan were typed.
引用
收藏
页码:599 / 605
页数:7
相关论文
共 50 条
  • [21] Evaluation of Beckman Paragon CZE 2000 system with updated software version for SPE, IFE/S and urine electrophoresis.
    Soffiati, G
    Paternoster, A
    Marchesini, G
    CLINICAL CHEMISTRY, 2000, 46 (06) : A176 - A177
  • [22] Analytical variation in the measurement of serum monoclonal component by capillary electrophoresis
    Luraschi, P
    Infusino, I
    Merlotti, C
    Franzini, C
    CLINICA CHIMICA ACTA, 2004, 349 (1-2) : 151 - 156
  • [23] Prospective study of serum protein capillary zone electrophoresis and immunotyping of monoclonal proteins by immunosubtraction
    Katzmann, JA
    Clark, R
    Sanders, E
    Landers, JP
    Kyle, RA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (04) : 503 - 509
  • [24] EVALUATION OF COMMUN INTERFERENCES ON SERUM PROTEIN HIGH RESOLUTION CAPILLARY ELECTROPHORESIS SYSTEM (CZE-HR) CAPILLARYS 2
    Emond, J. P.
    Levesque, M. H.
    Gingras, M. E.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S748 - S748
  • [25] The advantages of serum protein separation by capillary zone electrophoresis
    Obradovic, I
    Dajak, M
    Novakovic, N
    Becarevic, M
    Majkic-Singh, N
    CLINICA CHIMICA ACTA, 2005, 355 : S234 - S234
  • [26] Comparison of a clinical capillary electrophoresis system with agarose gel electrophoresis for evaluation of serum protein abnormalities
    Kip, N. Sertac
    Lamb, Colleen
    Killeen, Anthony A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (03) : 488 - 488
  • [27] Comparison of serum protein electrophoresis by agarose gel and capillary zone electrophoresis in a clinical setting
    Jolliff, CR
    Blessum, CR
    ELECTROPHORESIS, 1997, 18 (10) : 1781 - 1784
  • [28] Determination of poorly separated monoclonal serum proteins by capillary zone electrophoresis
    Le Bricon, T
    Launay, E
    Houze, P
    Bengoufa, D
    Bousquet, B
    Gourmel, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 775 (01): : 63 - 70
  • [29] Serum protein analysis comparing agarose gel electrophoresis versus an automated capillary zone electrophoresis system.
    Jolliff, C
    Hergenrader, P
    Bennett, S
    CLINICAL CHEMISTRY, 1996, 42 (06) : 38 - 38
  • [30] Evaluation of the Paragon 2000 CZE® system with software version 1.6 for detection of monoclonal proteins.
    Marien, G
    De Saedeleer, A
    Vranken, G
    Blanckaert, N
    Bossuyt, X
    CLINICAL CHEMISTRY, 2002, 48 (06) : A166 - A167