Comparison of the Tono-Pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma

被引:30
作者
Horowitz, GS
Byles, J
Lee, JL
D'Este, C
机构
[1] Univ Newcastle, Fac Hlth, Ctr Clin Epidemiol & Biostat, Newcastle, NSW 2308, Australia
[2] Sydney Eye Hosp, Sydney, NSW, Australia
关键词
comparison; intraocular pressure; Tono-Pen;
D O I
10.1111/j.1442-9071.2004.00907.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To estimate agreement between measurement of intraocular pressure (IOP) by the Tono-Pen and by the Goldmann tonometer. The hypothesis tested was that the mean difference in measurements would be <-2 mmHg. Methods: A prospective, single-centre, comparison study was carried out. The Tono-Pen was compared to the Goldmann tonometer in 138 patients systematically selected from two glaucoma clinics and among selected patients known to have high pressures (n = 22). For both groups the investigators were masked to the value of the Goldmann readings, the instruments were used in random order, and duplicated readings were taken with both tonometers. Results: In the systematically selected group, for right eyes, the mean difference in measurement between the Tono-Pen and Goldmann tonometer was -0.41 mmHg (SD: 2.59). The 95% limits of agreement were -5.5 to 4.7 mmHg, and the intraclass correlation coefficient (ICC) was 0.90. Results for left eyes were very similar. For patients with high pressures (greater than or equal to25 mmHg), the mean difference between instruments (Tono-Pen reading minus Goldmann reading): was -4.2 mmHg (P = 0.0004), SD: 4.6, 95% limits of agreement: -13.2 to 4.8 mmHg and ICC = 0.76. Combining the analysis for both groups, the Tono-Pen significantly underestimated the IOP when the pressure was >20 mmHg. Conclusions: The Tono-Pen cannot replace the Goldmann tonometer in the sense that it will give the same readings of IOP. The accuracy of the Tono-Pen is increased, if at least two measurements are taken per eye and then averaged.
引用
收藏
页码:584 / 589
页数:6
相关论文
共 19 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   THE TONO-PEN - A MANOMETRIC AND CLINICAL-STUDY [J].
BOOTHE, WA ;
LEE, DA ;
PANEK, WC ;
PETTIT, TH .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (09) :1214-1217
[5]  
CHRISTOFFERSEN T, 1993, ACTA OPHTHALMOL, V71, P103
[6]   Tonometry in adults and children -: A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo [J].
Eisenberg, DL ;
Sherman, BG ;
McKeown, CA ;
Schuman, JS .
OPHTHALMOLOGY, 1998, 105 (07) :1173-1181
[7]   AN EVALUATION OF THE TONO-PEN FOR THE MEASUREMENT OF DIURNAL INTRAOCULAR-PRESSURE [J].
FARRAR, SM ;
MILLER, KN ;
SHIELDS, MB ;
STOUP, CM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (04) :411-416
[8]  
FRENKEL REP, 1988, ARCH OPHTHALMOL-CHIC, V106, P750
[9]   TONO-PEN TONOMETRY IN NORMAL AND IN POSTKERATOPLASTY EYES [J].
GEYER, O ;
MAYRON, Y ;
LOEWENSTEIN, A ;
NEUDORFER, M ;
ROTHKOFF, L ;
LAZAR, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (09) :538-540
[10]  
Goldmann H, 1957, GLAUCOMA, P167