Effects of the Use of Smart Glasses on Eyesight

被引:4
作者
Herzog, Natasa Vujica [1 ]
Beharic, Amer [2 ]
机构
[1] Univ Maribor, Fac Mech Engn, Maribor, Slovenia
[2] Healthcare Ctr Dr Adolfa Drolca Maribor, Maribor, Slovenia
来源
HUMAN SYSTEMS ENGINEERING AND DESIGN II | 2020年 / 1026卷
关键词
Human-systems integration; Smart glasses; Industry; 4.0; Warehouse; VISION;
D O I
10.1007/978-3-030-27928-8_123
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Smart glasses, also named as data glasses, are an example of Head Mounted Display (HMD) with a great potential in different manufacturing environments. They collect data from a wireless network and project information directly into the user's eye. It is evidenced from the literature that HMD can cause headaches, pressure in the eyes, problems with focusing and difficulties with text reading. Therefore, we tried to research whether use of smart glasses could be harmful for the human eye or not. To study the addressed problems, a research was performed in testing warehouse environment at the Faculty of Mechanical Engineering. Users comfort was tested through questionnaire and several eyes investigations before and after use of smart glasses in Healthcare Center Maribor. The results of the performed ophthalmologic tests show that there are some statistically significant differences between tests results performed before and after use of smart glasses that cannot be overlooked.
引用
收藏
页码:808 / 812
页数:5
相关论文
共 14 条
[1]   Design and control of warehouse order picking: A literature review [J].
de Koster, Rene ;
Le-Duc, Tho ;
Roodbergen, Kees Jan .
EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2007, 182 (02) :481-501
[2]  
Han J., 2017, P HUM VIS EL IM, V2017, P212, DOI 10.2352/ISSN.2470-1173.2017.14.HVEI-146
[3]  
Hein DWE, 2017, ADV EDUC TECHNOL INS, P1, DOI 10.4018/978-1-5225-2110-5.ch001
[4]  
Josefsson P., 2017, POTENTIAL SMART GLAS
[5]  
Karatepe AS, 2017, TURK OFTALMOL DERG, V47, P80, DOI 10.4274/tjo.93763
[6]   The Impact of Visual Guided Order Picking on Ocular Comfort, Ocular Surface and Tear Function [J].
Klein-Theyer, Angelika ;
Horwath-Winter, Jutta ;
Rabensteiner, Dieter Franz ;
Schwantzer, Gerold ;
Wultsch, Georg ;
Aminfar, Haleh ;
Heidinger, Andrea ;
Boldin, Ingrid .
PLOS ONE, 2016, 11 (06)
[7]   VISUAL ISSUES IN THE USE OF A HEAD-MOUNTED MONOCULAR DISPLAY [J].
PELI, E .
OPTICAL ENGINEERING, 1990, 29 (08) :883-892
[8]  
Peli E., 1996, P IS T OPT IM INF AG, P364
[9]  
Ramulu P., STANDARD AUTOMATED P
[10]  
Rauschnabel P. A., 2016, AUGMENTED REALITY SM