Sample preparation: Quo Vadis?

被引:223
作者
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac034094h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sample preparation step in an analytical process typically consists of an extraction procedure that results in the isolation and enrichment of components of interest from a sample matrix. Extraction can vary in degree of selectivity, speed, and convenience and depends not only on the approach and conditions used but on the geometric configurations of the extraction phase. Increased interest in sample preparation research has been generated by the introduction of nontraditional extraction technologies. These technologies address the need for reduction of solvent use, automation, and miniaturization and ultimately lead to on-site in situ and in vivo implementation. These extraction approaches are frequently easier to operate but provide optimization challenges. More fundamental knowledge is required by an analytical chemist not only about equilibrium conditions but, more importantly, about the kinetics of mass transfer in the extraction systems. Optimization of this extraction process enhances overall analysis. Proper design of the extraction devices and procedures facilitates convenient on-site implementation, integration with sampling, and separation/quantification, automation, or both. The key to rational choice, optimization, and design is an understanding of the fundamental principles governing mass transfer of analytes in multiphase systems. The objective of this perspective is to summarize the fundamental aspects of sample preparation and anticipate future developments and research needs.
引用
收藏
页码:2543 / 2558
页数:16
相关论文
共 110 条
  • [71] Pawliszyn J., 2002, SAMPLING SAMPLE PREP
  • [72] Pawliszyn J., 1997, SOLID PHASE MICROEXT, P44
  • [73] Pawliszyn J., 1997, SOLID PHASE MICROEXT
  • [74] Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis
    Pedersen-Bjergaard, S
    Rasmussen, KE
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (14) : 2650 - 2656
  • [75] Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants
    Petty, JD
    Orazio, CE
    Huckins, JN
    Gale, RW
    Lebo, JA
    Meadows, JC
    Echols, KR
    Cranor, WL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) : 83 - 95
  • [76] Immunosorbents:: natural molecular recognition materials for sample preparation of complex environmental matrices
    Pichon, V
    Bouzige, M
    Miège, C
    Hennion, MC
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) : 219 - 235
  • [77] INFLUENCE OF SOLVENT EFFECTS ON THE BREAKTHROUGH VOLUME IN SOLID-PHASE EXTRACTION USING POROUS POLYMER PARTICLE-LOADED MEMBRANES
    POOLE, SK
    POOLE, CF
    [J]. ANALYST, 1995, 120 (06) : 1733 - 1738
  • [78] Potkay JA, 2003, PROC IEEE MICR ELECT, P395
  • [79] GAS EXTRACTION KINETICS OF VOLATILE ORGANIC-SPECIES FROM WATER WITH A HOLLOW FIBER MEMBRANE
    PRATT, KF
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2101 - 2106
  • [80] Development of a simple in-vial liquid-phase microextraction device for drag analysis compatible with capillary gas chromatography, capillary electrophoresis and high-performance liquid chromatography
    Rasmussen, KE
    Pedersen-Bjergaard, S
    Krogh, M
    Ugland, HG
    Gronhaug, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) : 3 - 11