Effect of morphine on respiratory drive in trigger ventilated pre-term infants

被引:6
作者
Quinn, MW [1 ]
Vokes, A [1 ]
机构
[1] Univ Exeter, Sch Postgrad Med & Hlth Sci, Dept Child Hlth, Exeter EX2 5DW, Devon, England
关键词
pre-term; morphine; morphine-6-glucuronide; respiration;
D O I
10.1016/S0378-3782(00)00082-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The response to morphine (100 microgram (mu g)/kg bolus, 10 mu g/kg/h infusion) of 14 babies (median birth weight/gestation 1.37 kg/30 weeks) trigger ventilated for hyaline membrane disease was compared to a group of 26 babies (median birth weight/gestation 1.1 kg/28 weeks) also trigger ventilated for hyaline membrane disease but not treated with morphine. The effect of morphine on triggered breath rate was very variable with no significant difference between the groups seen until 12 h after starting the infusion (mean [95% CI] difference = - 17 [-33, -2] breaths/nnin). In those babies (n = 11) who had plasma morphine levels measured there was no significant reduction in triggered rate over time despite significantly increasing plasma morphine levels. Babies who produced morphine-6-glucuronide at 12 h showed a significantly greater reduction in triggered breath rate than those who did not (median change - 22 breaths/min compared to - 4 breaths/min). (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 18 条
  • [1] Analgesia for ventilated neonates: Where do we stand?
    Ambalavanan, N
    Carlo, WA
    [J]. JOURNAL OF PEDIATRICS, 1999, 135 (04) : 403 - 405
  • [2] Monitoring interactions between spontaneous respiration and mechanical inflations in preterm neonates
    Bignall, S
    Dixon, P
    Quinn, C
    Kitney, R
    [J]. CRITICAL CARE MEDICINE, 1997, 25 (03) : 545 - 553
  • [3] Morphine metabolites
    Christrup, LL
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (01) : 116 - 122
  • [4] CORRUPT PA, 1991, J MED CHEM, V34, P1272
  • [5] Dimitriou G, 1998, ACTA PAEDIATR, V87, P1256
  • [6] HARTLEY R, 1993, BRIT J CLIN PHARMACO, V35, P314
  • [7] USE OF SEDATIVES AND MUSCLE-RELAXANTS IN NEWBORN BABIES RECEIVING MECHANICAL VENTILATION
    LEVENE, MI
    QUINN, MW
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1992, 67 (07): : 870 - 873
  • [8] LYNN AM, 1993, ANESTH ANALG, V77, P695
  • [9] MORPHINE PHARMACOKINETICS IN EARLY INFANCY
    LYNN, AM
    SLATTERY, JT
    [J]. ANESTHESIOLOGY, 1987, 66 (02) : 136 - 139
  • [10] Marlow N, 1992, N Engl J Med, V327, P126