Five-year outcomes of rapid-deployment aortic valve replacement with the Edwards Intuity valve

被引:7
作者
Pelce, E. [1 ]
Porto, A. [1 ]
Gariboldi, V. [1 ]
Ben Lagha, A. [1 ]
Amanatiou, C. [1 ]
Collart, F. [1 ]
Theron, A. [1 ]
机构
[1] La Timone Hosp, Dept Cardiac Surg, F-13005 Marseille, France
关键词
aortic valve replacement; rapid‐ aortic valve deployment; 5‐ year; outcomes; overall mortality; prospective; single‐ center; PROSPECTIVE MULTICENTER; INFECTIVE ENDOCARDITIS; IMPLANTATION; ASSOCIATION; PERFORMANCE; EXPERIENCE; STENOSIS; TRIAL;
D O I
10.1111/jocs.15665
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This report presents 5-year outcomes of the rapid-deployment Edwards Intuity valve in a prospective, single-center study. Methods All patients who underwent an aortic valve replacement (AVR) with an Edwards Intuity bioprosthesis at La Timone Hospital, Marseille, France, from July 2012 to June 2015 were assessed over a 5-year follow-up period. The primary outcome was overall mortality at 5 years. Secondary outcomes were reoperation, overall mortality and stroke, cardiovascular mortality, composite endpoints defined by the updated Valve Academic Research Consortium-2 (VARC-2), periprosthetic regurgitation, prosthesis-patient mismatch, and the need for new pacemaker implantation. Results In total, 170 consecutive patients were assessed, of which 67.1% were males. The mean age was 76 years, mean EuroSCORE II was 3.5% and 5-year overall mortality was 12.4%. At 5 years, reoperation was 2.9%, overall mortality and stroke was 4.1% per patient-year, and cardiovascular mortality was 4.7%. VARC clinical efficacy and VARC time-related valve safety were achieved in 46.0% and 59.9% of patients, respectively. At one month VARC device success was 71.2% and VARC early safety was 87.1%. At one year, mild and moderate periprosthetic regurgitation were 2.4% and 0.6%, respectively, and moderate and severe prosthesis-patient mismatch were 18.8% and 4.8%, respectively. Conduction disturbances needing new PPI occurred in 3.5% patients. Conclusion The 5-year outcomes of AVR with the Edwards Intuity valve system demonstrate satisfactory midterm safety and excellent haemodynamic performance.
引用
收藏
页码:2826 / 2833
页数:8
相关论文
共 25 条
[1]   THE PREVALENCE OF INFECTIVE ENDOCARDITIS AFTER AORTIC-VALVE REPLACEMENT [J].
AGNIHOTRI, AK ;
MCGIFFIN, DC ;
GALBRAITH, AJ ;
OBRIEN, MF .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (06) :1708-1724
[2]   Cross-clamp time is an independent predictor of mortality and morbidity in low- and high-risk cardiac patients [J].
Al-Sarraf, Nael ;
Thalib, Lukman ;
Hughes, Anne ;
Houlihan, Maighread ;
Tolan, Michael ;
Young, Vincent ;
McGovern, Eillish .
INTERNATIONAL JOURNAL OF SURGERY, 2011, 9 (01) :104-109
[3]   Five-Year Outcomes of Transfemoral Transcatheter Aortic Valve Replacement or Surgical Aortic Valve Replacement in a Real World Population Final Results From the OBSERVANT Study [J].
Barbanti, Marco ;
Tamburino, Corrado ;
D'Errigo, Paola ;
Biancari, Fausto ;
Ranucci, Marco ;
Rosato, Stefano ;
Santoro, Gennaro ;
Fusco, Danilo ;
Seccareccia, Fulvia .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (07)
[4]   TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve [J].
Barnhart, Glenn R. ;
Accola, Kevin D. ;
Grossi, Eugene A. ;
Woo, Y. Joseph ;
Mumtaz, Mubashir A. ;
Sabik, Joseph F. ;
Slachman, Frank N. ;
Patel, Himanshu J. ;
Borger, Michael A. ;
Garrett, H. Edward, Jr. ;
Rodriguez, Evelio ;
McCarthy, Patrick M. ;
Ryan, William H. ;
Duhay, Francis G. ;
Mack, Michael J. ;
Chitwood, W. Randolph, Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (02) :241-+
[5]  
Baumgartner H, 2017, EUR HEART J, VJ38
[6]   Can Perceval sutureless valve reduce the rate of patient-prosthesis mismatch? [J].
Belluschi, Igor ;
Moriggia, Stefano ;
Giacomini, Andrea ;
Del Forno, Benedetto ;
Di Sanzo, Stefania ;
Blasio, Andrea ;
Scafuri, Antonio ;
Alfieri, Ottavio .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (06) :1093-1099
[7]   Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trialaEuro [J].
Borger, Michael A. ;
Dohmen, Pascal M. ;
Knosalla, Christoph ;
Hammerschmidt, Robert ;
Merk, Denis R. ;
Richter, Markus ;
Doenst, Torsten ;
Conradi, Lenard ;
Treede, Hendrik ;
Moustafine, Vadim ;
Holzhey, David M. ;
Duhay, Francis ;
Strauch, Justus .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (04) :713-720
[8]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA) [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Lluis ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Luis Zamorano, Jose ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hector ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Luis Tamargo, Juan ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Baensch, Dietmar ;
Baumgartner, Helmut .
EUROPEAN HEART JOURNAL, 2013, 34 (29) :2281-2329
[9]   Pledget-Armed Sutures Affect the Haemodynamic Performance of Biologic Aortic Valve Substitutes: A Preliminary Experimental and Computational Study [J].
Capelli, Claudio ;
Corsini, Chiara ;
Biscarini, Dario ;
Ruffini, Francesco ;
Migliavacca, Francesco ;
Kocher, Alfred ;
Laufer, Guenther ;
Taylor, Andrew M. ;
Schievano, Silvia ;
Andreas, Martin ;
Burriesci, Gaetano ;
Rath, Claus .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (01) :17-29
[10]   Outcome of rapid deployment aortic valves: long-term experience after 700 implants [J].
Coti, Iuliana ;
Haberl, Thomas ;
Scherzer, Sabine ;
Werner, Paul ;
Shabanian, Shiva ;
Kocher, Alfred ;
Laufer, Guenther ;
Andreas, Martin .
ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (04) :314-321