Measurement of bone density around total knee arthroplasty using fan-beam dual energy X-ray absorptiometry

被引:41
作者
Soininvaara, T
Kröger, H
Jurvelin, JS
Miettinen, H
Suomalainen, O
Alhava, E
机构
[1] Kuopio Univ Hosp, Dept Surg, SF-70210 Kuopio, Finland
[2] Kuopio Univ Hosp, Dept Clin Physiol, SF-70210 Kuopio, Finland
关键词
knee arthroplasty; BMD; DXA; reproducibility; precision;
D O I
10.1007/s002230001111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The clinical survival of joint arthroplasties is clearly associated with the quality of surrounding bone environment. Bone mineral density (BMD) is an important measure of bone strength and quality. Periprosthetic BMD can be measured by using dual-energy X-ray absorptiometry (DXA) with special software algorithms. We studied short-term reproducibility of the periprosthetic BMD measurements after total knee arthroplasty (TKA) in 30 patients with primary osteoarthrosis. The operated knees and the contralateral control knees were measured twice and the results were expressed as a coefficient of variation (CV%). The average precision error was 3.1% in femoral regions of interest (ROI) and 2.9% in tibial ROIs after TKA. In the prosthesis-free control knees, CV% were similar; 3.2% and 2.5%, respectively. The best precision was found in the femoral diaphyses above the implant (1.3%), whereas the least reproducible BMD was determined in the patellar region of the TKA knees (6.9%). Our results confirm that DXA measures precisely small bone mineral changes around TKA and makes it possible to follow bone remodeling DXA and may provide a feasible method for monitoring TKA in the future.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 23 条
  • [1] ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY
    COHEN, B
    RUSHTON, N
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03): : 479 - 483
  • [2] Assessment of bone surrounding implants in goats: Ex vivo measurements by dual X-ray absorptiometry
    Corten, FGA
    Caulier, H
    vanderWaerden, JPCM
    Kalk, W
    Corstens, FHM
    Jansen, JA
    [J]. BIOMATERIALS, 1997, 18 (06) : 495 - 501
  • [3] DIGIOIA AM, 1990, CLIN ORTHOPAEDICS, V271, P135
  • [4] SWITCHING FROM DXA PENCIL-BEAM TO FAN-BEAM .1. STUDIES IN-VITRO AT 4 CENTERS
    EIKEN, P
    BARENHOLDT, O
    JENSEN, LB
    GRAM, J
    NIELSEN, SP
    [J]. BONE, 1994, 15 (06) : 667 - 670
  • [5] EL-HAJJ FULEIHAN G, 1995, J BONE MINER RES, V10, P1004
  • [6] QUANTITATIVE ULTRASOUND OF THE TIBIA - A NOVEL-APPROACH FOR ASSESSMENT OF BONE STATUS
    FOLDES, AJ
    RIMON, A
    KEINAN, DD
    POPOVTZER, MM
    [J]. BONE, 1995, 17 (04) : 363 - 367
  • [7] Lateral spine dual energy X-ray absorptiometry - Bone mineral measurement with fan-beam design: Effect of osteophytic calcifications on lateral and anteroposterior spine BMD
    Franck, H
    Munz, M
    Scherrer, M
    vonLilienfeldToal, H
    [J]. RHEUMATOLOGY INTERNATIONAL, 1995, 15 (04) : 151 - 154
  • [8] ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES
    GLUER, CC
    BLAKE, G
    LU, Y
    BLUNT, BA
    JERGAS, M
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) : 262 - 270
  • [9] EFFECT OF FEMORAL ROTATION ON BONE-MINERAL DENSITY-MEASUREMENTS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOH, JCH
    LOW, SL
    BOSE, K
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) : 340 - 343
  • [10] DETERMINATION OF BONE-MINERAL DENSITY BY DUAL X-RAY ABSORPTIOMETRY IN PATIENTS WITH UNCEMENTED TOTAL HIP-ARTHROPLASTY
    KIRATLI, BJ
    HEINER, JP
    MCBEATH, AA
    WILSON, MA
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (06) : 836 - 844