Renewable Energy Management System: Optimum Design and Hourly Dispatch

被引:55
|
作者
Mohandes, Baraa [1 ]
Wahbah, Maisam [2 ]
Moursi, Mohamed Shawky El [1 ]
El-Fouly, Tarek H. M. [1 ]
机构
[1] Khalifa Univ, EECS Dept, Adv Power & Energy Ctr, Abu Dhabi 127788, U Arab Emirates
[2] Khalifa Univ, Dept Biomed Engn, Healthcare Engn Innovat Ctr HEIC, Abu Dhabi 127788, U Arab Emirates
关键词
Wind forecasting; Renewable energy sources; Schedules; Load modeling; Optimization; Degradation; Uncertainty; Deep learning; multiplicative weights update; rolling horizon; hybrid renewable energy; dynamic ramping limit; proxy value of battery energy; STORAGE-SYSTEM; WIND-SPEED; POWER; GENERATION; FLEXIBILITY; INTEGRATION; OPERATIONS; COPULA; PV;
D O I
10.1109/TSTE.2021.3058252
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper introduces a new framework for optimum design and operation of hybrid renewable energy plants (HREP) augmented with battery energy storage systems (BESS). A new renewable energy management system (REMS) is developed comprising three components: 1) Enhanced joint forecasting of wind and solar outputs based on deep neural networks and also multiplicative weights update (MWU); 2) an advanced optimization model for sizing the HREP-BESS components and the policy of BESS operation; and 3) Augmenting the rolling hourly dispatch for HREP-BESS with a novel dynamic ramping limit and a criterion for reduction of deviations from the hour-ahead dispatch schedule. The proposed REMS tool enables maintaining the inter-hourly ramping of the HREP-BESS output within a threshold. In this context, a novel dynamic ramp limit is proposed to minimize the energy curtailment during operation and maximize energy sales to the power grid. The advantage of the proposed REMS tool over the classical renewable energy systems operation scheme is the mitigation of the volatility of renewable energy sources (RES) by suppressing extreme ramping events with minimum curtailment. Moreover, the costs and revenues of the HREP-BESS design and operation are assessed over a 25 years period. The design problem is solved for different scenarios, and the optimal solution always encloses a hybrid mix of renewables where the share of the PV plant can reach up to 37.1% of the total plant size. With the proposed REMS, the curtailment of RES never exceeds 12.9% even when the HREP is operated without a reserve margin. For the selected design, the optimum BESS capacity is 12.9% of the HREP capacity. The number of hours which observe a ramping violation event is 2.4% of the season's length (2184 hours). 99% of all ramping events fall within the defined ramping limits. The use of the MWU method increases the total profit by 2.53% compared with adopting the average forecast.
引用
收藏
页码:1615 / 1628
页数:14
相关论文
共 50 条
  • [21] The impact of energy dispatch strategy on design optimization of hybrid renewable energy systems
    Lee, Kun
    Kum, Dongsuk
    2019 IEEE MILAN POWERTECH, 2019,
  • [22] Enterprise energy supply system design management based on renewable energy sources
    Drobyazko, S.
    Skrypnyk, M.
    Radionova, N.
    Hryhorevska, O.
    Matiukha, M.
    GLOBAL JOURNAL OF ENVIRONMENTAL SCIENCE AND MANAGEMENT-GJESM, 2021, 7 (03): : 1 - 14
  • [23] Optimum Economic Dispatch of Interconnected Microgrid with Energy Storage System
    Asaduz-Zaman, Md.
    Chowdhury, A. Hasib
    2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION COMMUNICATION TECHNOLOGY (ICEEICT 2015), 2015,
  • [24] Economic Dispatch Optimization for system integrating renewable energy sources
    Jihane, Kartite
    Mohamed, Cherkaoui
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY, 2018, 1968
  • [25] Optimum community energy storage for renewable energy and demand load management
    Parra, David
    Norman, Stuart A.
    Walker, Gavin S.
    Gillott, Mark
    APPLIED ENERGY, 2017, 200 : 358 - 369
  • [26] Optimum design and analysis of a dynamic energy management scheme for HESS in renewable power generation applications
    Srinivas Punna
    Udaya Bhasker Manthati
    SN Applied Sciences, 2020, 2
  • [27] Optimum design and analysis of a dynamic energy management scheme for HESS in renewable power generation applications
    Punna, Srinivas
    Manthati, Udaya Bhasker
    SN APPLIED SCIENCES, 2020, 2 (03):
  • [28] The design and dispatch strategy of renewable energy absorption facility on pelagic island
    Ding, Suyang
    Lin, Xiangning
    Chen, Zhe
    Wang, Zhixun
    Li, Zhengtian
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 118
  • [29] Design a Control Mechanism for the Power Management of a Standalone Renewable Energy System
    Ganguly, P.
    Kalam, A.
    Zayegh, A.
    2019 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, CONTROL AND AUTOMATION (ICPECA-2019), 2019, : 198 - 203
  • [30] Optimum Facility Design in Large Hospital using Renewable Energy
    Mizuno, Yuji
    Tanaka, Yoshito
    Kurokawa, Fujio
    Matsui, Nobumasa
    2019 8TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA 2019), 2019, : 712 - 716