Minimum detection limits and applications of proton and helium induced X-ray emission using transition-edge sensor array

被引:3
|
作者
Kayhko, M. [1 ]
Palosaari, M. R. J. [2 ]
Laitinen, M. [1 ]
Arstila, K. [1 ]
Maasilta, I. J. [4 ]
Fowler, J. W. [3 ]
Doriese, W. B. [3 ]
Ullom, J. N. [3 ]
Sajavaara, T. [1 ]
机构
[1] Univ Jyvaskyla, Dept Phys, POB 35, FI-40014 Jyvaskyla, Finland
[2] Stresstech Oy Tikkutehtaantie 1, Vaajakoski 40800, Finland
[3] NIST, 325 Broadway, Boulder, CO 80305 USA
[4] Univ Jyvaskyla, Nanosci Ctr, Dept Phys, POB 35, FI-40014 Jyvaskyla, Finland
基金
芬兰科学院;
关键词
PIXE; TES; Minimum detection limit; Helium-induced X-ray emission; MICROCALORIMETERS; LINES;
D O I
10.1016/j.nimb.2017.02.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have determined minimum detection limits, MDLs, for elements 14 <= Z <= 86 using a transition edge sensor array, TES array, and as a comparison using an Amptek X-123SDD silicon drift detector, SDD. This was done using a 3 MeV proton beam and a 5.1 MeV helium beam. MDLs were determined for a thin film sample on top of C substrate, and for a bulk sample containing mostly Al. Due to the higher peak-to-background ratio, lower detection limits were obtainable using the TES array for most of the elements. However, for elements 30 <= Z <= 45 the performance of the TES array was not as good as the SDD performance. This is due to the limitations of the TES used at energies >10 key. The greatest advantage of TES comes, however, when detecting low intensity peaks close to high intensity peaks. Such a case was demonstrated by measuring a fly ash with overlapping Ti, V, Ba, and Ce peaks, where minimum detection limits of V, Ba, and Ce were decreased by factor of 620, 400, and 680, respectively, compared to the SDD. (C) 2017 Elsevier B.V. All rights reserved .
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [41] Castanea sativa shells and fruits: Compositional analysis by proton induced X-ray emission
    Corregidor, Victoria
    Antonio, Amilcar L.
    Alves, Luis C.
    Verde, Sandra Cabo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 477 : 98 - 103
  • [42] Active moss biomonitoring technique for atmospheric elemental contamination in Hanoi using proton induced X-ray emission
    Le Hong Khiem
    Sera, Koichiro
    Hosokawa, Takako
    Le Dai Nam
    Nguyen Huu Quyet
    Frontasyeva, Marina
    My, Trinh Thi Thu
    Nguyen Thi Bao My
    Zinicovscaia, Inga
    Nguyen The Nghia
    Trinh Dinh Trung
    Khuat Thi Hong
    Nguyen Ngoc Mai
    Duong Van Thang
    Nguyen An Son
    Tran Thien Thanh
    Xayheungsy, Sonexay
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 325 (02) : 515 - 525
  • [43] Active moss biomonitoring technique for atmospheric elemental contamination in Hanoi using proton induced X-ray emission
    Le Hong Khiem
    Koichiro Sera
    Takako Hosokawa
    Le Dai Nam
    Nguyen Huu Quyet
    Marina Frontasyeva
    Trinh Thi Thu My
    Nguyen Thi Bao My
    Inga Zinicovscaia
    Nguyen The Nghia
    Trinh Dinh Trung
    Khuat Thi Hong
    Nguyen Ngoc Mai
    Duong Van Thang
    Nguyen An Son
    Tran Thien Thanh
    Sonexay Xayheungsy
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 325 : 515 - 525
  • [44] Impact of the Absorber-Coupling Design for Transition-Edge-Sensor X-Ray Calorimeters
    de Wit, M.
    Gottardi, L.
    Taralli, E.
    Nagayoshi, K.
    Ridder, M. L.
    Akamatsu, H.
    Bruijn, M. P.
    Hoogeveen, R. W. M.
    van der Kuur, J.
    Ravensberg, K.
    Vaccaro, D.
    Gao, J-R
    den Herder, J-W A.
    PHYSICAL REVIEW APPLIED, 2021, 16 (04)
  • [45] Applications of laser-induced breakdown spectroscopy for cultural heritage: A comparison with X-ray Fluorescence and Particle Induced X-ray Emission techniques
    Lazic, V.
    Vadrucci, M.
    Fantoni, R.
    Chiari, M.
    Mazzinghi, A.
    Gorghinian, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 149 : 1 - 14
  • [46] Comparison of proton and helium induced M subshell X-ray production cross sections with the ECUSAR theory
    Cohen, D. D.
    Stelcer, E.
    Crawford, J.
    Atanacio, A.
    Doherty, G.
    Lapicki, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 318 : 11 - 14
  • [47] Position-sensing transition-edge sensors for large-field, high-energy-resolution X-ray imaging spectroscopy
    Figueroa-Feliciano, E
    Stahle, CK
    Finkbeiner, FM
    Li, M
    Lindeman, MA
    Tralshawala, N
    Stahle, CM
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 419 - 427
  • [48] Elemental analysis of bone: proton-induced X-ray emission testing in forensic cases
    Warren, MW
    Falsetti, AB
    Kravchenko, II
    Dunnam, FE
    Van Rinsvelt, HA
    Maples, WR
    FORENSIC SCIENCE INTERNATIONAL, 2002, 125 (01) : 37 - 41
  • [49] A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins
    Moosavi, K.
    Vatankhah, S.
    Salimi, J.
    Moradi, M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 8 (02): : 117 - 121
  • [50] Studies of some elements in urinary stones by proton induced X-ray emission (PIXE) technique
    Singh, NKS
    Sarma, HNK
    Kumar, S
    Arunachalam, J
    INDIAN JOURNAL OF PHYSICS, 2004, 78 (06) : 511 - 513