A Kalman filter approach to track fast impedance changes in electrical impedance tomography

被引:134
|
作者
Vauhkonen, M
Karjalainen, PA
Kaipio, JP
机构
[1] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
[2] Univ Oulu, Dept Math Sci, FIN-90571 Oulu, Finland
关键词
electrical impedance tomography; Kalman filter; time-varying imaging;
D O I
10.1109/10.664204
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In electrical impedance tomography (EIT), an estimate for the cross-sectional impedance distribution is obtained from the body by using current and voltage measurements made from the boundary. All well-known reconstruction algorithms use a full set of independent current patterns for each reconstruction. In some applications, the impedance changes may be so fast that information on the time evolution of the impedance distribution is either lost or severely blurred. In this paper, we propose an algorithm for EIT reconstruction that is able to track fast changes in the impedance distribution. The method is based on the formulation of EIT as a state-estimation problem and the recursive estimation of the state with the aid of the Kalman filter. The performance of the proposed method is evaluated with a simulation of human thorax in a situation in which the impedances of the ventricles change rapidly. We show that with optimal current patterns and proper parameterization, the proposed approach yields significant enhancement of the temporal resolution over the conventional reconstruction strategy.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [1] Electrical impedance tomography using the extended Kalman filter
    Trigo, FC
    Gonzalez-Lima, R
    Amato, MBP
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (01) : 72 - 81
  • [2] Recursive estimation of fast impedance changes in electrical impedance tomography and a related problem
    Kaipio, JP
    Somersalo, E
    Karjalainen, PA
    Vauhkonen, M
    COMPUTATIONAL, EXPERIMENTAL, AND NUMERICAL METHODS FOR SOLVING ILL-POSED INVERSE IMAGING PROBLEMS: MEDICAL AND NONMEDICAL APPLICATIONS, 1997, 3171 : 208 - 216
  • [3] Nonstationary phase boundary estimation in electrical impedance tomography using unscented Kalman filter
    Ijaz, Umer Zeeshan
    Khambampati, Anil Kumar
    Lee, Jeong Seong
    Kim, Sin
    Kim, Kyung Youn
    JOURNAL OF COMPUTATIONAL PHYSICS, 2008, 227 (15) : 7089 - 7112
  • [4] Fast approach to calculate the ballastless track impedance
    Zhang, Hanhua
    Li, Jun
    Zou, Jun
    Wang, Zhixin
    Yang, Jin
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 37 (01) : 176 - 188
  • [5] Electrical Impedance Tomography and the Fast Multipole Method
    Bikowski, J
    Mueller, J
    IMAGE RECONSTRUCTION FROM INCOMPLETE DATA III, 2004, 5562 : 129 - 140
  • [6] Image reconstruction in time-varying electrical impedance tomography based on the extended Kalman filter
    Kim, KY
    Kim, BS
    Kim, MC
    Lee, YJ
    Vauhkonen, M
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (08) : 1032 - 1039
  • [7] Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    Caroline A Grant
    Trang Pham
    Judith Hough
    Thomas Riedel
    Christian Stocker
    Andreas Schibler
    Critical Care, 15
  • [8] ORIGIN OF IMPEDANCE CHANGES RELATED TO LUNG PERFUSION IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Sondergaard, S.
    Tesselaar, E.
    Samuelsson, A.
    Fagerberg, A.
    Orman, J.
    Viksten, J. L.
    Hallen, K.
    Einarsson, H.
    Sjoberg, F.
    Aneman, A.
    INTENSIVE CARE MEDICINE, 2010, 36 : S95 - S95
  • [9] Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    Grant, Caroline A.
    Trang Pham
    Hough, Judith
    Riedel, Thomas
    Stocker, Christian
    Schibler, Andreas
    CRITICAL CARE, 2011, 15 (01):
  • [10] Imaging fast electrical activity in the brain with electrical impedance tomography
    Aristovich, Kirill Y.
    Packham, Brett C.
    Koo, Hwan
    dos Santos, Gustavo Sato
    McEvoy, Andy
    Holder, David S.
    NEUROIMAGE, 2016, 124 : 204 - 213