Retrofit of distillation columns in biodiesel production plants

被引:24
作者
Nguyen, Nghi [1 ]
Demirel, Yasar [1 ]
机构
[1] Univ Nebraska Lincoln, Dept Chem & Biomol Engn, Lincoln, NE 68508 USA
关键词
Thermodynamic analysis; Column grand composite curves; Exergy loss; Retrofitting; Thermodynamic efficiency; WASTE COOKING OIL; THERMODYNAMIC ANALYSIS; DIABATIC DISTILLATION; BINARY DISTILLATION; ENTROPY PRODUCTION; EXERGY ANALYSIS; OPTIMIZATION; SIMULATION; SYSTEMS;
D O I
10.1016/j.energy.2009.12.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
Column grand composite curves and the exergy loss profiles produced by the Column-Targeting Tool of the Aspen Plus simulator are used to assess the performance of the existing distillation columns, and reduce the costs of operation by appropriate retrofits in a biodiesel production plant. Effectiveness of the retrofits is assessed by means of thermodynamics and economic improvements. We have considered a biodiesel plant utilizing three distillation columns to purify biodiesel (fatty acid methyl ester) and byproduct glycerol as well as reduce the waste. The assessments of the base case simulation have indicated the need for modifications for the distillation columns. For column 1202, the retrofits consisting of a feed preheating and reflux ratio modification have reduced the total exergy loss by 47%, while T301 and T302 columns exergy losses decreased by 61% and 52%, respectively. After the retrofits, the overall exergy loss for the three columns has decreased from 7491.86 kW to 3627.97 kW. The retrofits required a fixed capital cost of approximately $239,900 and saved approximately $1,900,000/year worth of electricity. The retrofits have reduced the consumption of energy considerably, and leaded to a more environmentally friendly operation for the biodiesel plant considered. Published by Elsevier Ltd.
引用
收藏
页码:1625 / 1632
页数:8
相关论文
共 25 条
[1]   Efficient use of an intermediate reboiler or condenser in a binary distillation [J].
Agrawal, R ;
Herron, DM .
AICHE JOURNAL, 1998, 44 (06) :1303-1315
[2]   Thermodynamic analysis of crude oil distillation systems [J].
Al-Muslim, H ;
Dincer, I .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (07) :637-655
[3]   Exergy analysis of single- and two-stage crude oil distillation units [J].
Al-Muslim, H ;
Dincer, I ;
Zubair, SM .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2003, 125 (03) :199-207
[4]   Exergetic analysis of distillation processes -: A case study [J].
Araujo, Antonio B. ;
Brito, Romildo P. ;
Vasconcelos, Luis S. .
ENERGY, 2007, 32 (07) :1185-1193
[5]   Effect of feed on optimal thermodynamic performance of a distillation column [J].
Bandyopadhyay, S .
CHEMICAL ENGINEERING JOURNAL, 2002, 88 (1-3) :175-186
[6]   Temperature-enthalpy curve for energy targeting of distillation columns [J].
Bandyopadhyay, S ;
Malik, RK ;
Shenoy, UV .
COMPUTERS & CHEMICAL ENGINEERING, 1998, 22 (12) :1733-1744
[7]  
Cengel YA, 2002, Thermodynamics an Engineering Approach, Vfourth
[8]   A new exergy method for process analysis and optimization [J].
Chang, H ;
Li, JW .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (10) :2771-2784
[9]   Entropy production and exergy loss in experimental distillation columns [J].
de Koeijer, G ;
Rivero, R .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (08) :1587-1597
[10]   Retrofit of distillation columns using thermodynamic analysis [J].
Demirel, Y .
SEPARATION SCIENCE AND TECHNOLOGY, 2006, 41 (05) :791-817