Analysis of resistance to punching shear of beamless reinforced concrete floor slabs

被引:0
|
作者
Salna, R [1 ]
Marciukaitis, G [1 ]
Vainiunas, P [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Dept Reinforced Concrete & Masonry Struct, LT-10223 Vilnius, Lithuania
关键词
punching shear strength; load capacity; critical perimeter; flexural and shear reinforcement;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The analysis of analytical calculation methods provided in various design codes shows that the main factors influencing the punching shear strength of the column-floor slab's combination are estimated differently. Therefore, various calculation methodologies present different empirical coefficients. Calculation methodologies propose different methods for the estimation of the bending moment. Some methodologies estimate the bending moment only partly, whereas others do not estimate it at all. Due to the number of factors, the difference between various calculation methodologies may differ up to 1,59 times, whereas the difference between the results of theoretical calculations and test research, may vary from 1,19 to 2,06 times. Moreover, none of the calculation methodologies completely estimates the singularities of the shear reinforcement, as well as its allocation character and type. Besides, different types of concrete have different resistance to shear. The article explains the main factors that have the greatest influence on the punching shear strength.
引用
收藏
页码:615 / 619
页数:5
相关论文
共 50 条
  • [21] Punching shear behavior of lightweight fiber reinforced concrete slabs
    Caratelli, Angelo
    Imperatore, Stefania
    Meda, Alberto
    Rinaldi, Zila
    COMPOSITES PART B-ENGINEERING, 2016, 99 : 257 - 265
  • [22] Shear reinforcement against punching in reinforced concrete flat slabs
    Regan, P.E.
    Samadian, F.
    Structural Engineer, 2001, 79 (10): : 24 - 31
  • [23] Punching shear testing of reinforced concrete slabs, and design implications
    Papanikolaou, KV
    Tegos, IA
    Kappos, AJ
    MAGAZINE OF CONCRETE RESEARCH, 2005, 57 (03) : 167 - 177
  • [24] PUNCHING SHEAR BEHAVIOR OF RESTRAINED REINFORCED-CONCRETE SLABS
    KUANG, JS
    MORLEY, CT
    ACI STRUCTURAL JOURNAL, 1992, 89 (01) : 13 - 19
  • [25] Verification of Punching Shear Provisions for Reinforced Concrete Flat Slabs
    Gardner, Noel J.
    ACI STRUCTURAL JOURNAL, 2011, 108 (05) : 572 - 580
  • [26] Punching shear behavior of recycled aggregate reinforced concrete slabs
    Mahmoud, Zaki I.
    El tony, Tony M.
    Saeed, Kawan S.
    ALEXANDRIA ENGINEERING JOURNAL, 2018, 57 (02) : 841 - 849
  • [27] Effects of openings on the punching shear strength of reinforced concrete slabs
    Mostofinejad, Davood
    Jafarian, Navid
    Naderi, Ali
    Mostofinejad, Amirmahdi
    Salehi, Mohamad
    STRUCTURES, 2020, 25 : 760 - 773
  • [28] Punching shear behaviour of concrete slabs reinforced with CFRP grids
    Huang, Zhen
    Zhao, Yingkai
    Zhang, Jiwen
    Wu, Yue
    STRUCTURES, 2020, 26 : 617 - 625
  • [29] Using an Alternative Method of Analysis to Evaluate Punching Shear Capacity in Existing Post-Tensioned Shear Reinforced Concrete Floor Slabs
    Kritzler, R. W.
    Guedelhoefer, O. C.
    Lammert, B. T.
    Macicak, W. J.
    Structures Congress 2015, 2015, : 1052 - 1064
  • [30] Residual punching shear capacity of corroded reinforced concrete slabs
    Yang, Zhihong
    Zhang, Xinchen
    Li, Bing
    MAGAZINE OF CONCRETE RESEARCH, 2023, 75 (02) : 82 - 96