CE-ESI-MS/MS as a rapid screening tool for the comparison of protein-ligand interactions

被引:14
|
作者
Hoffmann, Thomas [1 ]
Martin, Markus M. [1 ]
机构
[1] Univ Saarland, D-66041 Saarbrucken, Germany
关键词
CE; Chymotrypsin; MS/MS; Protein-ligand interaction; IONIZATION-MASS SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; BINDING; MS; CHYMOTRYPSIN; CHYMOSTATIN; COMPLEXES; SYSTEMS;
D O I
10.1002/elps.200900585
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In drug development, the combinatorial synthesis of drug libraries is common use, therefore efficient tools for the characterization of drug candidates and the extent of interaction between a drug and its target protein is a central question of analytical interest. While biological activity is tested today by enzyme assays, MS techniques attract more and more attention as an alternative for a rapid comparison of drug target interactions CE enables the separation of proteins and drug enzyme complexes preserving their physiological activity in aqueous media By hyphenating CE with ESI-MS/MS, the binding strength of enzyme inhibitors can be deduced from MS/MS experiments, which selectively release the inhibitor from the drug target complex after CID In this study, a-chymotrypsin (CT), a serine protease, was chosen as a model compound. Chymostatin is a naturally occurring peptide aldehyde binding to CT through a hemiacetal bond and electrostatic interaction. First, a CE separation was developed, which allows the analysis of alpha-CT and a chymotrypsin chymostatin complex under MS-compatible conditions The use of neutral-coated CE capillaries was mandatory to reduce analyte wall interactions. ESI-quadrupole ion trap-MS was worked out to demonstrate the selective drug release after CID Fragmentation of the drug enzyme complex was monitored in dependence from the excitation energy in the ion trap, leading to the V-50 voltage that enables 50% complex fragmentation as a reference value for chymotrypsin chymostatin complex. A stable CE-ESI-MS/MS setup was established, which preserves the drug enzyme complexes during ionization-desolvation processes With this optimized setup, different CT inhibitors could be investigated and compared
引用
收藏
页码:1248 / 1255
页数:8
相关论文
共 50 条
  • [41] Development of a novel sheathless CE-ESI-MS interface via a CO2 laser ablated opening
    Vermeire, Pieter-Jan
    Van Schepdael, Ann
    Petersen, Nickolaj J.
    TALANTA, 2020, 214 (214)
  • [42] A new CE-ESI-MS method for the detection of stable hemoglobin acetaldehyde adducts, potential biomarkers of alcohol abuse
    De Benedetto, Giuseppe E.
    Fanigliulo, Matteo
    ELECTROPHORESIS, 2009, 30 (10) : 1798 - 1807
  • [44] Indirect assessment of small hydrophobic ligand binding to a model protein using a combination of ESI MS and HDX/ESI MS
    Xiao, H
    Kaltashov, IA
    Eyles, SJ
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (05) : 506 - 515
  • [45] CE-ESI-MS analysis of singly charged inorganic and organic anions using a dicationic reagent as a complexing agent
    Lin, Xiuli
    Gerardi, Anthony R.
    Breitbach, Zachary S.
    Armstrong, Daniel W.
    Colyer, Christa L.
    ELECTROPHORESIS, 2009, 30 (22) : 3918 - 3925
  • [46] Enantiomeric separation of chiral dipeptides by CE-ESI-MS employing a partial filling technique with chiral crown ether
    Xia, Shifei
    Zhang, Lan
    Lu, Minghua
    Qiu, Bin
    Chi, Yuwu
    Chen, Guonan
    ELECTROPHORESIS, 2009, 30 (16) : 2837 - 2844
  • [47] NMR as a tool to target protein-protein and protein-ligand interactions
    Lalli, D.
    De Pablo, R.
    Del Conte, R.
    Turano, P.
    FEBS JOURNAL, 2012, 279 : 437 - 437
  • [48] Stabilizing protein-ligand complexes in ESI-MS using solution additives: Comparing the effects of amino acids and imidazole
    Kitova, Elena N.
    Yao, Yuyu
    Klassen, John S.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 420 : 2 - 8
  • [49] Rapid protein identification using monolithic enzymatic microreactor and LC-ESI-MS/MS
    Duan, JC
    Liang, Z
    Yang, C
    Zhang, J
    Zhang, LH
    Zhang, WB
    Zhang, YK
    PROTEOMICS, 2006, 6 (02) : 412 - 419
  • [50] Investigating the position of the separation capillary and emitter tube tips in a nanoflow sheath-liquid CE-ESI-MS interface to decouple the ESI potential
    Konasova, Renata
    Koval, Dusan
    Hosek, Jan
    Kasicka, Vaclav
    TALANTA, 2021, 228