CE-ESI-MS/MS as a rapid screening tool for the comparison of protein-ligand interactions

被引:14
|
作者
Hoffmann, Thomas [1 ]
Martin, Markus M. [1 ]
机构
[1] Univ Saarland, D-66041 Saarbrucken, Germany
关键词
CE; Chymotrypsin; MS/MS; Protein-ligand interaction; IONIZATION-MASS SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; BINDING; MS; CHYMOTRYPSIN; CHYMOSTATIN; COMPLEXES; SYSTEMS;
D O I
10.1002/elps.200900585
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In drug development, the combinatorial synthesis of drug libraries is common use, therefore efficient tools for the characterization of drug candidates and the extent of interaction between a drug and its target protein is a central question of analytical interest. While biological activity is tested today by enzyme assays, MS techniques attract more and more attention as an alternative for a rapid comparison of drug target interactions CE enables the separation of proteins and drug enzyme complexes preserving their physiological activity in aqueous media By hyphenating CE with ESI-MS/MS, the binding strength of enzyme inhibitors can be deduced from MS/MS experiments, which selectively release the inhibitor from the drug target complex after CID In this study, a-chymotrypsin (CT), a serine protease, was chosen as a model compound. Chymostatin is a naturally occurring peptide aldehyde binding to CT through a hemiacetal bond and electrostatic interaction. First, a CE separation was developed, which allows the analysis of alpha-CT and a chymotrypsin chymostatin complex under MS-compatible conditions The use of neutral-coated CE capillaries was mandatory to reduce analyte wall interactions. ESI-quadrupole ion trap-MS was worked out to demonstrate the selective drug release after CID Fragmentation of the drug enzyme complex was monitored in dependence from the excitation energy in the ion trap, leading to the V-50 voltage that enables 50% complex fragmentation as a reference value for chymotrypsin chymostatin complex. A stable CE-ESI-MS/MS setup was established, which preserves the drug enzyme complexes during ionization-desolvation processes With this optimized setup, different CT inhibitors could be investigated and compared
引用
收藏
页码:1248 / 1255
页数:8
相关论文
共 50 条
  • [1] Speciation of Aluminum by CE-ESI-MS and CE-ICP-MS
    Nakamoto, Daisuke
    Tanaka, Miho
    BUNSEKI KAGAKU, 2014, 63 (05) : 383 - 390
  • [2] CE-ESI-MS shows potential
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (09) : VII - VII
  • [3] Development of a sheathless CE-ESI-MS interface
    Hirayama, Akiyoshi
    Abe, Hiroshi
    Yamaguchi, Nozomi
    Tabata, Sho
    Tomita, Masaru
    Soga, Tomoyoshi
    ELECTROPHORESIS, 2018, 39 (11) : 1382 - 1389
  • [4] Direct analysis of reduced and oxidized glutathione by CE-ESI-MS/MS
    Assuncao, Nilson Antonio
    Soare, Chrislaine Oliveira
    Dominque, Olivia
    Stevanil, Cassius Vinicius
    Becharal, Etelvino Jose Henriques
    FREE RADICAL BIOLOGY AND MEDICINE, 2007, 43 : S13 - S13
  • [5] Complexation of metals by phytosiderophores revealed by CE-ESI-MS and CE-ICP-MS
    Dell'mour, Madeleine
    Koellensperger, Gunda
    Quirino, Joselito P.
    Haddad, Paul R.
    Stanetty, Christian
    Oburger, Eva
    Puschenreiter, Markus
    Hann, Stephan
    ELECTROPHORESIS, 2010, 31 (07) : 1201 - 1207
  • [6] A new method for screening and determination of diuretics by on-line CE-ESI-MS
    Lu, Minghua
    Tong, Ping
    Xiao, Hui
    Xia, Shifei
    Zheng, Xinyu
    Liu, Wei
    Zhang, Lan
    Chen, Guonan
    ELECTROPHORESIS, 2007, 28 (09) : 1461 - 1471
  • [7] Peptide characterization by CE-ESI-MS with orthogonal spray
    Serwe, M
    Ross, G
    CHROMATOGRAPHIA, 1999, 49 (Suppl 1) : S73 - S77
  • [8] Peptide characterization by CE-ESI-MS with orthogonal spray
    M. Serwe
    G. Ross
    Chromatographia, 1999, 49 : S73 - S77
  • [9] CE-ESI-MS/MS: A microanalytical technique for probing physiological function.
    Aebersold, R
    Ducret, A
    Figeys, D
    Gu, M
    Zhang, YN
    Watts, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 201 - ANYL
  • [10] Application of CE-ICP-MS and CE-ESI-MS in metalloproteomics:: challenges, developments, and limitations
    Prange, A
    Pröfrock, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (03) : 372 - 389