Transcatheter closure of "Surgical" ostium secundum atrial septal defects with GORE® Cardioform ASD Occluder

被引:3
作者
Santoro, Giuseppe [1 ]
Pizzuto, Alessandra [1 ]
Cuman, Magdalena [1 ]
Haxhiademi, Dorela [2 ]
Marchese, Pietro [1 ]
Franchi, Eliana [1 ]
Marrone, Chiara [1 ]
Pak, Vitali [3 ]
Assanta, Nadia [1 ]
Cantinotti, Massimiliano [1 ]
机构
[1] Tuscany Fdn G Monasterio, Natl Res Council, Pediat Cardiol & Cardiac Surg, Heart Hosp G Pasquinucci, Massa, Italy
[2] Tuscany Fdn G Monasterio, Anesthesia & Intens Care Unit, Heart Hosp G Pasquinucci, Natl Res Council, Massa, Italy
[3] Tuscany Fdn G Monasterio, Natl Res Council, Pediat Cardiac Surg, Heart Hosp G Pasquinucci, Massa, Italy
关键词
atrial septal defect; device; interventional cardiac catheterization; low-weight child; DEVICE CLOSURE; PERCUTANEOUS CLOSURE; OVAL FOSSA; FEASIBILITY; CHILDREN; IMPACT;
D O I
10.1111/jocs.16786
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the GORE (R) Cardioform ASD Occluder (GCA)(WL Gore & Associates) device for closure of ostium secundum atrial septal defects (ASDs) with predicted indication for surgical correction. Background Closure of large ASD in small children by transcatheter approach is still challenging. This study evaluated the results of GCA in this subset of patients in a tertiary referral center. Methods Between January 2020 and March 2022, 97 children underwent transcatheter ASD closure at our Institution. Of them, 38 had a large defect (diameter/weight > 1.2 or diameter/body surface area > 20 mm/m(2)), predicted suitable for surgery and underwent closure with GCA. Procedure results and midterm outcome are reported. Results Patients' age and weight were 5.5 +/- 1.5 years and 19.7 +/- 4.7 kg, respectively. Absolute and relative ASD size was 21.5 +/- 3.6 mm, 1.1 +/- 0.2 mm/kg, and 27.7 +/- 4.6 mm/m(2), respectively, resulting in QP/QS of 2.0 +/- 0.8. Three patients were sent to surgery after balloon sizing. Four of the remaining 35 patients who underwent device deployment, needed rescue or elective surgery due to device embolization (n = 1), device instability (n = 2) or new-onset tricuspid valve regurgitation (n = 1). Procedure feasibility was 88.6%. Major complications were recorded in two patients (5.7%). Minor complications were recorded in five patients (14.3%). Complete closure at discharge was 90.3% (28/31 pts) rising to 100% at the last follow-up evaluation. Wireframe fracture rate at the 6 months examination was 52%, without clinical and instrumental consequences. Conclusions Percutaneous treatment with GCA device is effective and safe in a high percentage of ASD children with predicted indications for surgical correction.
引用
收藏
页码:3200 / 3206
页数:7
相关论文
共 30 条
[1]   Gore Cardioform atrial septal occluder: deployment procedure and techniques for closing challenging secundum atrial septal defects [J].
Aggarwal, Varun ;
Mohan, Arjun K. ;
Bass, John ;
Steinberger, Julia ;
Said, Sameh M. ;
Qureshi, Athar M. .
CARDIOLOGY IN THE YOUNG, 2021, 31 (12) :1885-1892
[2]   Percutaneous versus surgical closure of secundum atrial septal defects: a systematic review and meta-analysis of currently available clinical evidence [J].
Butera, Gianfranco ;
Biondi-Zoccai, Giuseppe ;
Sangiorgi, Giuseppe ;
Abella, Raul ;
Giamberti, Alessandro ;
Bussadori, Claudio ;
Sheiban, Imad ;
Saliba, Zackhia ;
Santoro, Tiberio ;
Pelissero, Gabriele ;
Carminati, Mario ;
Frigiola, Alessandro .
EUROINTERVENTION, 2011, 7 (03) :377-385
[3]   Transcatheter closure of secundum atrial defect in small children [J].
Cardenas, L. ;
Panzer, J. ;
Boshoff, D. ;
Malekzadeh-Milani, S. ;
Ovaert, C. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) :447-452
[4]   Impact of the Amplatzer Atrial Septal Occluder Device on Left Ventricular Function in Pediatric Patients [J].
Castaldi, Biagio ;
Santoro, Giuseppe ;
Di Salvo, Giovanni ;
Gaio, Gianpiero ;
Palladino, Maria Teresa ;
D'Aiello, Fabio ;
Iacono, Carola ;
Pacileo, Giuseppe ;
Calabro, Raffaele ;
Russo, Maria Giovanna .
PEDIATRIC CARDIOLOGY, 2013, 34 (07) :1645-1651
[5]   Initial Clinical Experience With the GORE® CARDIOFORM ASD Occluder for Transcatheter Atrial Septal Defect Closure [J].
de Hemptinne, Quentin ;
Horlick, Eric M. ;
Osten, Mark D. ;
Millan, Xavier ;
Tadros, Victor-Xavier ;
Pighi, Michele ;
Barlatey, Francisco Gonzalez ;
Alnasser, Sami M. ;
Miro, Joaquim ;
Asgar, Anita W. ;
Ibrahim, Reda .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (03) :495-503
[6]   Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder [J].
Divekar, A ;
Gaamangwe, T ;
Shaikh, N ;
Raabe, M ;
Ducas, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) :1213-1218
[7]   Catheter-Based Closure of Atrial Septal Defects in the Oval Fossa With the Amplatzer® Device in Patients in Their First or Second Year of Life [J].
Fischer, G. ;
Smevik, B. ;
Kramer, H. H. ;
Bjornstad, P. G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (07) :949-955
[8]   Atrial septal defect closure: indications and contra-indications [J].
Fraisse, Alain ;
Latchman, Monica ;
Sharma, Shiv-Raj ;
Bayburt, Selin ;
Amedro, Pascal ;
di Salvo, Giovanni ;
Baruteau, Alban Elouen .
JOURNAL OF THORACIC DISEASE, 2018, 10 :S2874-S2881
[9]   Use of the GORE® CARDIOFORM Septal Occluder for percutaneous closure of secundum atrial septal defects: Results of the multicenter US IDE trial [J].
Gillespie, Matthew J. ;
Javois, Alexander J. ;
Moore, Phillip ;
Forbes, Thomas ;
Paolillo, Joseph A. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (07) :1296-1304
[10]   Transcatheter closure of large atrial septal defects (ASDs) in symptomatic children with device/weight ratio ≥1.5 [J].
Houeijeh, Ali ;
Hascoet, Sebastien ;
Bouvaist, Helene ;
Hadeed, Khaled ;
Petit, Jerome ;
Godart, Francois ;
Fraisse, Alain .