Investigation of the effect of hepatic metabolism on off-target cardiotoxicity in a multi-organ human-on-a-chip system

被引:122
作者
Oleaga, Carlota [1 ]
Riu, Anne [2 ]
Rothemund, Sandra [1 ]
Lavado, Andrea [1 ]
McAleer, Christopher W. [1 ,4 ]
Long, Christopher J. [1 ,4 ]
Persaud, Keisha [1 ]
Narasimhan, Narasimhan Sriram [4 ]
My Tran [4 ]
Roles, Jeffry [1 ]
Carmona-Moran, Carlos A. [1 ]
Sasserath, Trevor [4 ]
Elbrecht, Daniel H. [1 ,4 ]
Kumanchik, Lee [1 ]
Bridges, L. Richard [4 ]
Martin, Candace [1 ]
Schnepper, Mark T. [1 ]
Ekman, Gail [1 ]
Jackson, Max [1 ]
Wang, Ying I. [1 ,5 ]
Note, Reine [2 ]
Langer, Jessica [3 ]
Teissier, Silvia [2 ]
Hickman, James J. [1 ]
机构
[1] Univ Cent Florida, NanoSci Technol Ctr, 12424 Res Pkwy,Suite 400, Orlando, FL 32826 USA
[2] LOreal Res & Innovat Div, Aulnay Sous Bois, France
[3] LOreal Res & Innovat Div, Clark, NJ USA
[4] Hesperos Inc, 3259 Progress Dr,Room 158, Orlando, FL 32826 USA
[5] Cornell Univ, Nancy E & Peter C Meinig Sch Biomed Engn, Ithaca, NY 14853 USA
关键词
Human-on-a-chip; Functional readouts; Cardiotoxicity; Non-invasive; Metabolism; CELL-DERIVED CARDIOMYOCYTES; HIGH-DOSE CYCLOPHOSPHAMIDE; DRUG-DRUG INTERACTION; IN-VITRO SYSTEM; HUMAN PLASMA; MICROPHYSIOLOGICAL SYSTEM; PHARMACEUTICAL RESEARCH; MICROFLUIDIC CELL; HUMAN HEPATOCYTES; ANTICANCER DRUGS;
D O I
10.1016/j.biomaterials.2018.07.062
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regulation of cosmetic testing and poor predictivity of preclinical drug studies has spurred efforts to develop new methods for systemic toxicity. Current in vitro assays do not fully represent physiology, often lacking xenobiotic metabolism. Functional human multi-organ systems containing iPSC derived cardiomyocytes and primary hepatocytes were maintained under flow using a low-volume pumpless system in a serum-free medium. The functional readouts for contractile force and electrical conductivity enabled the non-invasive study of cardiac function. The presence of the hepatocytes in the system induced cardiotoxic effects from cyclophosphamide and reduced them for terfenadine due to drug metabolism, as expected from each compound's pharmacology. A computational fluid dynamics simulation enabled the prediction of terfenadine-fexofenadine pharmacokinetics, which was validated by HPLC-MS. This in vitro platform recapitulates primary aspects of the in vivo crosstalk between heart and liver and enables pharmacological studies, involving both organs in a single in vitro platform. The system enables non-invasive readouts of cardiotoxicity of drugs and their metabolites. Hepatotoxicity can also be evaluated by biomarker analysis and change in metabolic function. Integration of metabolic function in toxicology models can improve adverse effects prediction in preclinical studies and this system could also be used for chronic studies as well.
引用
收藏
页码:176 / 190
页数:15
相关论文
共 101 条
[41]   Definition of metabolism-dependent xenobiotic toxicity with co-cultures of human hepatocytes and mouse 3T3 fibroblasts in the novel integrated discrete multiple organ co-culture (IdMOC) experimental system: Results with model toxicants aflatoxin B1, cyclophosphamide and tamoxifen [J].
Li, Albert P. ;
Uzgare, Aarti ;
LaForge, Yumiko S. .
CHEMICO-BIOLOGICAL INTERACTIONS, 2012, 199 (01) :1-8
[42]   Overview: Evaluation of metabolism-based drug toxicity in drug development [J].
Li, Albert P. .
CHEMICO-BIOLOGICAL INTERACTIONS, 2009, 179 (01) :1-3
[43]   Metabolism Comparative Cytotoxicity Assay (MCCA) and Cytotoxic Metabolic Pathway Identification Assay (CMPIA) with cryopreserved human hepatocytes for the evaluation of metabolism-based cytotoxicity in vitro: Proof-of-concept study with aflatoxin B1 [J].
Li, Albert P. .
CHEMICO-BIOLOGICAL INTERACTIONS, 2009, 179 (01) :4-8
[44]  
LING KHJ, 1995, DRUG METAB DISPOS, V23, P631
[45]   Design Optimization of Liquid-Phase Flow Patterns for Microfabricated Lung on a Chip [J].
Long, C. ;
Finch, C. ;
Esch, M. ;
Anderson, W. ;
Shuler, M. ;
Hickman, J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (06) :1255-1267
[46]   μOrgano: A Lego®-Like Plug & Play System for Modular Multi-Organ-Chips [J].
Loskill, Peter ;
Marcus, Sivan G. ;
Mathur, Anurag ;
Reese, Willie Mae ;
Healy, Kevin E. .
PLOS ONE, 2015, 10 (10)
[47]  
LOW JE, 1982, CANCER RES, V42, P830
[48]   Ultrastructural Signs of Cyclophosphamide-Induced Damage to Cardiomyocytes [J].
Lushnikova, E. L. ;
Nepmnyashchikh, L. M. ;
Sviridov, E. A. ;
Klinnikova, M. G. .
BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2008, 146 (03) :366-371
[49]   Human iPSC-based Cardiac Microphysiological System For Drug Screening Applications [J].
Mathur, Anurag ;
Loskill, Peter ;
Shao, Kaifeng ;
Huebsch, Nathaniel ;
Hong, SoonGweon ;
Marcus, Sivan G. ;
Marks, Natalie ;
Mandegar, Mohammad ;
Conklin, Bruce R. ;
Lee, Luke P. ;
Healy, Kevin E. .
SCIENTIFIC REPORTS, 2015, 5
[50]   Design and Demonstration of a Pumpless 14 Compartment Microphysiological System [J].
Miller, Paula G. ;
Shuler, Michael L. .
BIOTECHNOLOGY AND BIOENGINEERING, 2016, 113 (10) :2213-2227