Evaluation of the non-calibrated pulse contour cardiac output monitor FloTrac/Vigileo against thermodilution in standing horses

被引:3
作者
Kutter, Annette P. N. [1 ]
Bettschart-Wolfensberger, Regula [1 ]
Schwarzwald, Colin C. [2 ]
Portier, Karine G. [3 ,4 ]
Ringer, Simone K. [1 ]
机构
[1] Univ Zurich, Vetsuisse Fac, Equine Dept, Sect Anaesthesiol, Winterthurerstr 258c, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Vetsuisse Fac, Equine Dept, Clin Equine Internal Med, CH-8057 Zurich, Switzerland
[3] Univ Lyon, Sect Anaesthesiol, VetAgro Sup Vet Campus, Marcy Letoile, France
[4] INSERM, CarMeN Cardiovasc Metab Diabetol & Nutr, UMR 1060, F-69008 Lyon, France
关键词
cardiac output measurement; FloTrac/Vigileo; horses; pulse contour analysis; thermodilution cardiac output; WAVE-FORM ANALYSIS; TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHY; LITHIUM DILUTION; ANESTHETIZED HORSES; PRESSURE; FLOTRAC; PERFORMANCE; PARAMETERS; PRECISION; ACCURACY;
D O I
10.1111/vaa.12281
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the non-calibrated, minimally invasive cardiac output (CO) monitor FloTrac/Vigileo (FloTrac) against thermodilution (TD) CO in standing horses. Study design Prospective, experimental trial. Animals Nine adult horses weighing a median (range) of 535 (470-602) kg. Methods Catheters were placed in the right atrium, pulmonary artery and carotid artery under local anaesthesia. CO was measured 147 times by TD and FloTrac and indexed to body weight. Changes in CO were achieved with romifidine or xylazine and dobutamine constant rate infusions. Bland-Altman analysis, concordance and polar plot analysis were used to assess agreement and ability to track changes in CO. Results Mean +/- standard deviation COTD of 48 +/- 16 mL kg(-1) minute(-1) (range: 19-93 mL kg(-1) minute(-1)) and mean COFloTrac of 9 +/- 3 mL kg(-1) minute(-1) (range: 5-21 mL kg(-1) minute(-1)) were measured. Low agreement with a large mean bias of 39 mL kg(-1) minute(-1) and wide limits of agreement of 8-70 mL kg(-1) minute(-1) were found. The percentage error of 108% and precision of TD of +/- 18% resulted in an estimated precision of FloTrac of +/- 106%. Comparison of changes in COFloTrac with changes in COTD gave a concordance rate of 52% in the four-quadrant plot, and a mean polar angle of -11 degrees with radial limits of agreement of +/- 61 degrees in the polar plot. Mean arterial pressure (MAP) and COFloTrac were positively correlated (r = 0.5, p < 0.0001). No correlation of MAP with COTD was observed. Conclusions and clinical relevance The FloTrac system, originally designed for use in humans, neither measured absolute CO in standing horses accurately nor tracked relative changes in CO measured by TD correctly. The false dependence of COFloTrac on arterial blood pressure further discourages the use of this technique in horses.
引用
收藏
页码:153 / 162
页数:10
相关论文
共 40 条
[1]   Influence of drugs on the response characteristics of the LiDCO sensor: an in vitro study [J].
Ambrisko, T. D. ;
Kabes, R. ;
Moens, Y. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (02) :305-310
[2]   TECHNICAL AND METHODOLOGICAL REQUIREMENTS FOR RELIABLE HEMODYNAMIC MEASUREMENTS IN THE UNSEDATED CALF [J].
AMORY, H ;
LINDEN, AS ;
DESMECHT, DJM ;
ROLLIN, FA ;
MCENTEE, K ;
LEKEUX, PM .
VETERINARY RESEARCH COMMUNICATIONS, 1992, 16 (05) :391-401
[3]   Evaluation of a minimally invasive non-calibrated pulse contour cardiac output monitor (FloTrac/Vigileo) in anaesthetized dogs [J].
Bektas, Rima N. ;
Kutter, Annette P. N. ;
Hartnack, Sonja ;
Jud, Rahel S. ;
Schnyder, Manuela ;
Matos, Jose M. ;
Bettschart-Wolfensberger, Regula .
VETERINARY ANAESTHESIA AND ANALGESIA, 2012, 39 (05) :464-471
[4]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[5]   Cardiac output obtained by pulse pressure analysis: to calibrate or not to calibrate may not be the only question when used properly [J].
Cecconi, Maurizio ;
Malbrain, Manu L. N. G. .
INTENSIVE CARE MEDICINE, 2013, 39 (04) :787-789
[6]   Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)
[7]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[8]  
Corley KTT, 2003, J VET INTERN MED, V17, P262, DOI 10.1892/0891-6640(2003)017<0262:COTWSR>2.3.CO
[9]  
2
[10]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91