Gliclazide voltammetric sensor based on electropolymerized molecularly imprinted polypyrrole film onto glassy carbon electrode

被引:33
作者
Hrichi, Hajer [1 ]
Louhaichi, Mohamed Radhouan [2 ]
Monser, Lotfi [1 ]
Adhoum, Nafaa [1 ,3 ]
机构
[1] Carthage Univ, Natl Inst Appl Sci & Technol, Ctr Urbain Nord, Tunis 1080, Tunisia
[2] Natl Lab Pharmaceut Control, Tunis, Tunisia
[3] Kairouan Univ, Preparatory Sch Engn Studies, Kairouan, Tunisia
关键词
Molecularly imprinted polymer; Polypyrrole; Glassy carbon electrode; Electropolymerization; Gliclazide; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL SENSORS; DOSAGE FORMS; GLIPIZIDE; OXIDATION; METFORMIN; POLYMERS; STRATEGY; COLUMN; ACID;
D O I
10.1016/j.snb.2014.07.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gliclazide sensing was investigated based on differential pulse voltammetry measurements of an electropolymerized molecularly imprinted polymer (E-MIP) film. The E-MIP polymer was prepared via anodic electropolymerization of pyrrole in the presence of GLZ onto glassy carbon electrodes using cyclic voltammetry (CV). GLZ molecules are successfully trapped into the polypyrrole matrix creating, after their subsequent removal, shape-complementary artificial recognition sites. The effect of several significant operational parameters (monomer and template concentrations, number of CV scans, pH and incubation time) on film analytical performances were investigated and optimized. Under optimized conditions, the sensor response exhibited high sensitivity toward the target template and was linearly proportional to GLZ concentration (R-2 = 0.998) over the range 5 x 10(-11)4 x 10(-10) M, with a detection limit (3 sigma/m) of 1.2 x 10(-11) M. The precision of the method (R.S.D., n = 6) for within and between-days is better than 1.4% and 2.48%, respectively at 10(-10) M. Moreover, the selectivity of E-MIP sensor, against potentially competing molecules (Imp. B, Imp. E, glipizide, glibenclamide, glimepiride), was demonstrated. The developed E-MIP sensor was successfully applied to the determination of GLZ in three pharmaceutical products and gave results in close agreement with the reference HPLC method with mean recoveries between 95.4 and 98.8%, showing promising potential in practical applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 41 条
[31]   DETERMINATION OF GLICLAZIDE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION [J].
NOGUCHI, H ;
TOMITA, N ;
NARUTO, S ;
NAKANO, S .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 583 (02) :266-269
[32]   Determination of paracetamol based on electropolymerized-molecularly imprinted polypyrrole modified pencil graphite electrode [J].
Oezcan, Levent ;
Sahin, Yucel .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (02) :362-369
[33]  
Piletsky SA, 2002, ELECTROANAL, V14, P317, DOI 10.1002/1521-4109(200203)14:5<317::AID-ELAN317>3.3.CO
[34]  
2-X
[35]   Electrochemical oxidation of the hypoglycaemic drug gliclazide [J].
Radi, A ;
El Ries, MA ;
Bekhiet, GE .
ANALYTICAL LETTERS, 1999, 32 (08) :1603-1612
[36]   Theoretical study of molecular structure, pKa, lipophilicity, solubility, absorption, and polar surface area of some hypoglycemic agents [J].
Remko, Milan .
JOURNAL OF MOLECULAR STRUCTURE-THEOCHEM, 2009, 897 (1-3) :73-82
[37]   A simple and sensitive HPLC method for determination of gliclazide in human serum [J].
Rouini, MR ;
Mohajer, A ;
Tahami, MH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :383-386
[38]   Quantitative electrochemical and electrochromic behavior of terthiophene and carbazole containing conjugated polymer network film precursors: EC-QCM and EC-SPR [J].
Taranekar, Prasad ;
Fulghum, Timothy ;
Baba, Akira ;
Patton, Derek ;
Advincula, Rigoberto .
LANGMUIR, 2007, 23 (02) :908-917
[39]   A novel potentiometric sensor for L-ascorbic acid based on molecularly imprinted polypyrrole [J].
Tonelli, Domenica ;
Ballarin, Barbara ;
Guadagnini, Lorella ;
Mignani, Adriana ;
Scavetta, Erika .
ELECTROCHIMICA ACTA, 2011, 56 (20) :7149-7154
[40]   Electrochemical sensor for 2,4-dichlorophenoxy acetic acid using molecularly imprinted polypyrrole membrane as recognition element [J].
Xie, Chenggen ;
Gao, Shan ;
Guo, Qingbao ;
Xu, Ke .
MICROCHIMICA ACTA, 2010, 169 (1-2) :145-152