Evaluation of Cortical Bone Microdamage and Primary Stability of Orthodontic Miniscrew Using a Human Bone Analogue

被引:7
|
作者
Teekavanich, Chutimont [1 ,2 ]
Uezono, Masayoshi [1 ]
Takakuda, Kazuo [3 ]
Ogasawara, Takeshi [1 ]
Techalertpaisarn, Paiboon [2 ]
Moriyama, Keiji [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Maxillofacial Orthognath, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138510, Japan
[2] Chulalongkorn Univ, Dept Orthodont, Fac Dent, 34 Henri Dunant Rd, Bangkok 10330, Thailand
[3] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
关键词
orthodontic miniscrew; microdamage; primary stability; pilot hole; synthetic cortical bone; IMPLANT STABILITY; INSERTION; GENERATION;
D O I
10.3390/ma14081825
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Orthodontic miniscrews have gained popularity; however, they have some drawbacks, including screw loosening that results from bone resorption caused by excess microdamage created during screw insertion. Pilot hole preparation through the cortical bone is considered beneficial to avoid such microdamage, while an overly large pilot hole impairs primary stability. Hence, we used a human bone analogue to evaluate the microdamage and primary stability to estimate the optimal pilot hole size that would minimize the screw loosening risk. Ti6Al4V orthodontic miniscrews and 1.0-mm-thick synthetic cortical bone pieces were prepared. Various compressive loads were applied in indentation tests to test pieces' surfaces, and the microdamaged areas were confirmed as stress-whitening zones. Screw insertion tests were performed in which a miniscrew was inserted into the test pieces' pilot hole with a diameter of 0.7-1.2 mm in 0.1-mm intervals, and the stress-whitening area was measured. The insertion and removal torque were also measured to evaluate primary stability. The stress-whitening areas of the 1.0-1.2 mm pilot hole diameter groups were significantly smaller than those of the other groups (p < 0.05), whereas the 0.9 and 1.0 mm pilot hole diameter groups showed higher primary stability than other groups. In conclusion, the bone analogue could be utilized to evaluate microdamage in cortical bones and the primary stability of miniscrews.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Methodological approach for the detection of both microdamage and fluorochrome labels in ewe bone and human trabecular bone
    Burt-Pichat, Brigitte
    Follet, Helene
    Toulemonde, Gwendoline
    Arlot, Monique
    Delmas, Pierre
    Chapurlat, Roland
    JOURNAL OF BONE AND MINERAL METABOLISM, 2011, 29 (06) : 756 - 764
  • [42] Morphological Evaluation of Bone by CT to Determine Primary Stability-Clinical Study
    Takechi, Masaaki
    Ishioka, Yasuki
    Ninomiya, Yoshiaki
    Ono, Shigehiro
    Tada, Misato
    Nakagawa, Takayuki
    Sasaki, Kazuki
    Murodumi, Hiroshi
    Shigeishi, Hideo
    Ohta, Kouji
    MATERIALS, 2020, 13 (11)
  • [43] A CONTINUUM DAMAGE MECHANICS MODEL OF THE MICRODAMAGE PROCESS ZONE DURING CORTICAL BONE FRACTURE
    Dapaah, Daniel
    Bahmani, Aram
    Montesano, John
    Willett, Thomas L.
    MATERIALS TODAY-PROCEEDINGS, 2019, 7 : 402 - 409
  • [44] Influence of insertion depth on stress distribution in orthodontic miniscrew and the surrounding bone by finite element analysis
    Hirai, Yuzo
    Watanabe, Keiichiro
    Deguchi, Toru
    Ueda, Kanji
    Hamada, Kenichi
    Tanaka, Eiji
    DENTAL MATERIALS JOURNAL, 2021, 40 (05) : 1270 - 1276
  • [45] Quantitative biomechanical analysis of the influence of the cortical bone and implant length on primary stability
    Hong, Jongrak
    Lim, Young-Jun
    Park, Sang-Oh
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1193 - 1197
  • [46] Regional differences in cortical bone organization and microdamage prevalence in Rocky Mountain mule deer
    Skedros, JG
    Sybrowsky, CL
    Parry, TR
    Bloebaum, RD
    ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2003, 274A (01): : 837 - 850
  • [47] Cortical bone thickness and bone density effects on miniscrew success rates-A systematic review and meta-analysis
    Lee, Dong-Wook
    Park, Jae Hyun
    Bay, R. Curtis
    Choi, Sung-Kwon
    Chae, Jong-Moon
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2021, 24 : 92 - 102
  • [48] Evaluation of primary stability of implants in bovine bone defects models
    Kim, Minji
    Lee, Jae-Hyun
    Kim, Hyo-seon
    Lee, Su Young
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [49] Bone Density and Implant Primary Stability. A Study on Equine Bone Blocks
    Orlando, Francesco
    Arosio, Federico
    Arosio, Paolo
    Di Stefano, Danilo Alessio
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [50] Is motor-driven insertion of orthodontic miniscrews more advantageous than manual insertion? A micro-CT evaluation of bone miniscrew contact surface area and cortical microcracks in rabbits
    Alansari, Reem A.
    Zawawi, Khaled H.
    Vaiid, Nikhillesh
    Natto, Zuhair
    Adel, Samar M.
    Alshihri, Maha R.
    Alsadat, Mohammed
    Dause, Rania
    Agou, Shoroog
    Hassan, Ali H.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2024, 27 (06) : 853 - 859