Evaluation of Cortical Bone Microdamage and Primary Stability of Orthodontic Miniscrew Using a Human Bone Analogue

被引:7
|
作者
Teekavanich, Chutimont [1 ,2 ]
Uezono, Masayoshi [1 ]
Takakuda, Kazuo [3 ]
Ogasawara, Takeshi [1 ]
Techalertpaisarn, Paiboon [2 ]
Moriyama, Keiji [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Maxillofacial Orthognath, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138510, Japan
[2] Chulalongkorn Univ, Dept Orthodont, Fac Dent, 34 Henri Dunant Rd, Bangkok 10330, Thailand
[3] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
关键词
orthodontic miniscrew; microdamage; primary stability; pilot hole; synthetic cortical bone; IMPLANT STABILITY; INSERTION; GENERATION;
D O I
10.3390/ma14081825
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Orthodontic miniscrews have gained popularity; however, they have some drawbacks, including screw loosening that results from bone resorption caused by excess microdamage created during screw insertion. Pilot hole preparation through the cortical bone is considered beneficial to avoid such microdamage, while an overly large pilot hole impairs primary stability. Hence, we used a human bone analogue to evaluate the microdamage and primary stability to estimate the optimal pilot hole size that would minimize the screw loosening risk. Ti6Al4V orthodontic miniscrews and 1.0-mm-thick synthetic cortical bone pieces were prepared. Various compressive loads were applied in indentation tests to test pieces' surfaces, and the microdamaged areas were confirmed as stress-whitening zones. Screw insertion tests were performed in which a miniscrew was inserted into the test pieces' pilot hole with a diameter of 0.7-1.2 mm in 0.1-mm intervals, and the stress-whitening area was measured. The insertion and removal torque were also measured to evaluate primary stability. The stress-whitening areas of the 1.0-1.2 mm pilot hole diameter groups were significantly smaller than those of the other groups (p < 0.05), whereas the 0.9 and 1.0 mm pilot hole diameter groups showed higher primary stability than other groups. In conclusion, the bone analogue could be utilized to evaluate microdamage in cortical bones and the primary stability of miniscrews.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] THe effects of suppressed bone remodeling by bisphosphonates on microdamage accumulation and degree of mineralization in the cortical bone of dog rib
    T. Mashiba
    S. Mori
    S. Komatsubara
    Y. Cao
    T. Manabe
    H. Norimatsu
    D. B. Burr
    Journal of Bone and Mineral Metabolism, 2005, 23 : 36 - 42
  • [32] In vivo microdamage is an indicator of susceptibility to initiation and propagation of microdamage in human femoral trabecular bone
    Wu, Ziheng
    LaNeve, Anthony J.
    Niebur, Glen L.
    BONE, 2013, 55 (01) : 208 - 215
  • [33] Aging and matrix microdamage accumulation in human compact bone
    Schaffler, MB
    Choi, K
    Milgrom, C
    BONE, 1995, 17 (06) : 521 - 525
  • [34] The effects of suppressed bone remodeling by bisphosphonates on microdamage accumulation and degree of mineralization in the cortical bone of dog rib
    Mashiba, T
    Mori, S
    Burr, DB
    Komatsubara, S
    Cao, YP
    Manabe, T
    Norimatsu, H
    JOURNAL OF BONE AND MINERAL METABOLISM, 2005, 23 (Suppl 1) : 36 - 42
  • [35] The effects of cortical bone thickness and miniscrew implant root proximity on the success rate of miniscrew implant: A retrospective study
    Zhang, Shuting
    Choi, Yuhsin
    Li, Wa
    Shi, Danni
    Tang, Pei
    Yang, Li'an
    Wang, Yu
    Yang, Xin
    Wu, Jianyong
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2022, 25 (03) : 342 - 350
  • [36] Effect of longitudinal flutes on miniscrew implant stability and 3-dimensional bone formation
    Truong, Peter An V.
    Campbell, Phillip M.
    Kontogiorgos, Elias D.
    Taylor, Reginald W.
    Kyung, Hee-Moon
    Buschang, Peter H.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (06) : 950 - 957
  • [37] Microarchitecture influences microdamage accumulation in human vertebral trabecular bone
    Arlot, Monique E.
    Burt-Pichat, Brigitte
    Roux, Jean-Paul
    Vashishth, Deepak
    Bouxsein, Mary L.
    Delmas, Pierre D.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (10) : 1613 - 1618
  • [38] Effects of Pilot Hole Size and Bone Density on Miniscrew Implants' Stability
    Hung, Emily
    Oliver, Donald
    Kim, Ki Beom
    Kyung, Hee-Moon
    Buschang, Peter H.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (03) : 454 - 460
  • [39] Methodological approach for the detection of both microdamage and fluorochrome labels in ewe bone and human trabecular bone
    Brigitte Burt-Pichat
    Hélène Follet
    Gwendoline Toulemonde
    Monique Arlot
    Pierre Delmas
    Roland Chapurlat
    Journal of Bone and Mineral Metabolism, 2011, 29 : 756 - 764
  • [40] Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
    Wakamatsu, Kaien
    Doi, Kazuya
    Kobatake, Reiko
    Oki, Yoshifumi
    Tsuga, Kazuhiro
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (06):