Evaluation of Cortical Bone Microdamage and Primary Stability of Orthodontic Miniscrew Using a Human Bone Analogue

被引:7
|
作者
Teekavanich, Chutimont [1 ,2 ]
Uezono, Masayoshi [1 ]
Takakuda, Kazuo [3 ]
Ogasawara, Takeshi [1 ]
Techalertpaisarn, Paiboon [2 ]
Moriyama, Keiji [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Maxillofacial Orthognath, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138510, Japan
[2] Chulalongkorn Univ, Dept Orthodont, Fac Dent, 34 Henri Dunant Rd, Bangkok 10330, Thailand
[3] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
关键词
orthodontic miniscrew; microdamage; primary stability; pilot hole; synthetic cortical bone; IMPLANT STABILITY; INSERTION; GENERATION;
D O I
10.3390/ma14081825
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Orthodontic miniscrews have gained popularity; however, they have some drawbacks, including screw loosening that results from bone resorption caused by excess microdamage created during screw insertion. Pilot hole preparation through the cortical bone is considered beneficial to avoid such microdamage, while an overly large pilot hole impairs primary stability. Hence, we used a human bone analogue to evaluate the microdamage and primary stability to estimate the optimal pilot hole size that would minimize the screw loosening risk. Ti6Al4V orthodontic miniscrews and 1.0-mm-thick synthetic cortical bone pieces were prepared. Various compressive loads were applied in indentation tests to test pieces' surfaces, and the microdamaged areas were confirmed as stress-whitening zones. Screw insertion tests were performed in which a miniscrew was inserted into the test pieces' pilot hole with a diameter of 0.7-1.2 mm in 0.1-mm intervals, and the stress-whitening area was measured. The insertion and removal torque were also measured to evaluate primary stability. The stress-whitening areas of the 1.0-1.2 mm pilot hole diameter groups were significantly smaller than those of the other groups (p < 0.05), whereas the 0.9 and 1.0 mm pilot hole diameter groups showed higher primary stability than other groups. In conclusion, the bone analogue could be utilized to evaluate microdamage in cortical bones and the primary stability of miniscrews.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Cortical bone microdamage affects primary stability of orthodontic miniscrew
    Methawit, Panida
    Uezono, Masayoshi
    Ogasawara, Takeshi
    Techalertpaisarn, Paiboon
    Moriyama, Keiji
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2023, 12 (05) : 229 - 236
  • [2] Effect of cutting flute geometry of orthodontic miniscrew on cortical bone microdamage and primary stability using a human bone analog
    Wijarn, Sansanee
    Uezono, Masayoshi
    Takakuda, Kazuo
    Ogasawara, Takeshi
    Techalertpaisarn, Paiboon
    Moriyama, Keiji
    ORAL SCIENCE INTERNATIONAL, 2024,
  • [3] Microdamage in cortical bone due to the overtightening of orthodontic microscrews
    Wawrzinek, Christian
    Sommer, Thorsten
    Fischer-Brandies, Helge
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (02): : 121 - 134
  • [4] Effects of Intrabony Length and Cortical Bone Density on the Primary Stability of Orthodontic Miniscrews
    Jin, Jie
    Kim, Gi-Tae
    Kwon, Jae-Sung
    Choi, Sung-Hwan
    MATERIALS, 2020, 13 (24) : 1 - 13
  • [5] The association between thread pitch and cortical bone thickness influences the primary stability of orthodontic miniscrew implants: a study in human cadaver palates
    Budsabong, Chalermporn
    Trachoo, Vorapat
    Pittayapat, Pisha
    Chantarawaratit, Pintu-On
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2022, 11 (02) : 68 - 73
  • [6] Biomechanical effectiveness of cortical bone thickness on orthodontic microimplant stability: An evaluation based on the load share between cortical and cancellous bone
    Alrbata, Raed H.
    Yu, Wonjae
    Kyung, Hee-Moon
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (02) : 175 - 182
  • [7] Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants
    Pan, Chin-Yun
    Liu, Pao-Hsin
    Tseng, Yu-Chuan
    Chou, Szu-Ting
    Wu, Chao-Yi
    Chang, Hong-Po
    JOURNAL OF DENTAL SCIENCES, 2019, 14 (04) : 383 - 388
  • [8] Primary Stability of Orthodontic Titanium Miniscrews due to Cortical Bone Density and Re-Insertion
    Kim, Gi-Tae
    Jin, Jie
    Mangal, Utkarsh
    Lee, Kee-Joon
    Kim, Kwang-Mahn
    Choi, Sung-Hwan
    Kwon, Jae-Sung
    MATERIALS, 2020, 13 (19) : 1 - 12
  • [9] Microdamage of human cortical bone: Incidence and morphology in long bones
    Norman, TL
    Wang, Z
    BONE, 1997, 20 (04) : 375 - 379
  • [10] Modeling microdamage behavior of cortical bone
    Donaldson, Finn
    Ruffoni, Davide
    Schneider, Philipp
    Levchuk, Alina
    Zwahlen, Alexander
    Pankaj, Pankaj
    Mueller, Ralph
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2014, 13 (06) : 1227 - 1242