Stepwise gradient of buffer concentration for capillary electrochromatography of peptides on sulfonated naphthalimido-modified silyl silica gel

被引:10
作者
Ohyama, K [1 ]
Wada, M [1 ]
Kishikawa, N [1 ]
Ohba, Y [1 ]
Nakashima, K [1 ]
Kuroda, N [1 ]
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Course Pharmaceut Sci, Nagasaki 8528521, Japan
关键词
capillary electrochromatography; peptides; stepwise gradient; 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel;
D O I
10.1016/j.chroma.2004.12.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The advantage of using a stepwise gradient of buffer concentration in CEC was demonstrated with the mixed-mode stationary phase, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP). Before the application of a stepwise gradient, the effect of buffer concentration on the separations of six peptides and tryptic digests was investigated. Bubble formation caused by Joule heating at currents up to 95 LA was successfully suppressed by using SNAIP column even without pressurization, which contributed to a stepwise gradient of buffer concentration. Utilizing the stepwise gradient improved and shortened the separation of six peptides as compared to the separation under an isocratic elution. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 24 条
[1]   Comparative study of capillary electroendosmotic chromatography and electrically assisted gradient nano-liquid chromatography for the separation of peptides [J].
Adam, T ;
Unger, KK .
JOURNAL OF CHROMATOGRAPHY A, 2000, 894 (1-2) :241-251
[2]   Application of mixed mobile phases and a step gradient method in capillary electrochromatography for the separation of isomeric polycyclic aromatic hydrocarbon-deoxyribonucleoside adduct mixtures prepared in vitro [J].
Ding, JM ;
Szeliga, J ;
Dipple, A ;
Vouros, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :327-334
[3]   Step-gradient capillary electrochromatography [J].
Euerby, MR ;
Gilligan, D ;
Johnson, CM ;
Bartle, KD .
ANALYST, 1997, 122 (10) :1087-1088
[4]   The separation of biomolecules using capillary electrochromatography [J].
Fu, HJ ;
Huang, XD ;
Jin, WH ;
Zou, HF .
CURRENT OPINION IN BIOTECHNOLOGY, 2003, 14 (01) :96-100
[5]   Peptide analysis by rapid, orthogonal technologies with high separation selectivities and sensitivities [J].
Hearn, MTW .
BIOLOGICALS, 2001, 29 (3-4) :159-178
[6]   High-efficiency peptide analysis on monolithic multimode capillary columns:: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry [J].
Ivanov, AR ;
Horváth, C ;
Karger, BL .
ELECTROPHORESIS, 2003, 24 (21) :3663-3673
[7]   Automated microgradient system for capillary electrochromatography [J].
Kahle, V ;
Vázlerová, M ;
Welsch, T .
JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) :3-9
[8]   Profiling of impurities in heroin by capillary electrochromatography and laser-induced fluorescence detection [J].
Lurie, IS ;
Anex, DS ;
Fintschenko, Y ;
Choi, WY .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :421-427
[9]   Electrochromatographic characterization of etched chemically-modified capillaries with small synthetic peptides [J].
Matyska, MT ;
Pesek, JJ ;
Boysen, RI ;
Hearn, MTW .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :211-221
[10]   Study of flow rate in pressurized gradient capillary electrochromatography using splitter and separation of peptides using an Amide stationary phase [J].
Nakashima, R ;
Kitagawa, S ;
Yoshida, T ;
Tsuda, T .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :305-309