In Vitro Ion Release of Wires in Removable Orthodontic Appliances

被引:4
作者
Wepner, Lena [1 ]
Farber, Harald Andreas [2 ]
Jaensch, Andreas [2 ]
Weber, Anna [1 ]
Heuser, Florian [3 ]
Keilig, Ludger [1 ]
Singer, Lamia [1 ]
Bourauel, Christoph Peter [1 ]
机构
[1] Univ Bonn, Med Fac, Dent Sch, Oral Technol, D-53111 Bonn, Germany
[2] Univ Bonn, Med Fac, Inst Hyg & Publ Hlth, D-53127 Bonn, Germany
[3] Univ Bonn, Med Fac, Dent Sch, Dept Prosthet Dent,Preclin Educ & Mat Sci, D-53111 Bonn, Germany
关键词
removable appliance; orthodontic wire; corrosion; cytotoxicity; ORAL-MUCOSA CELLS; METAL-IONS; ARTIFICIAL SALIVA; DNA-DAMAGE; NICKEL; TITANIUM; CORROSION; CHROMIUM; VIVO; ALUMINUM;
D O I
10.3390/ma14123402
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Various orthodontic wire compositions and configurations are present on the market for removable appliances; however, there have still been only few studies focusing on the effect of resin color and additives such as glitter on corrosion of metallic wires under different conditions. Thus, the aim of the study was to compare concentrations of released ions (aluminium, chromium, nickel) in a corrosive medium under three different conditions: non-loaded wires, loaded wires, and non-loaded wires treated with Kukis(R) cleaning tablets. Six different wires made of three types of steel alloy were embedded in PMMA resin leaving one centimetre of each wire emerging from the resin to come into contact with the corrosive medium. Glitter particles were added to half of the produced test specimens. For the unloaded test series, five specimens of each group were covered in a petri dish with 50 mL of corrosive medium (pH 2.3) following EN-ISO 10271 for seven days at 37 degrees C. The wires for the mechanically loaded test specimens overlapped the resin by 5 cm and were clamped into a time-switched electric drive for a defined period of time before the samples were taken after a testing time of 7 days. In the third group, unloaded test specimens were transferred from their petri dishes into the prepared Kukis(R) solution every 24 h before being stored in the corrosive medium. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosive solution. Statistical analysis showed that the mechanical loading of all wires could significantly raise the diffusion of ions into the corrosive medium. The colour of the resin did not affect the concentration of the released ions. The Kukis(R) cleaning tabs could not lower the corrosion of the tested metals, as some of the wires were corroded even more using the brace cleanser. Glitter-containing test specimens showed significantly higher amounts of aluminium. Mechanical loading as well as the presence of glitter particles in the resin significantly affected ion concentrations.
引用
收藏
页数:17
相关论文
共 37 条
[1]   Scientific Opinion on Dietary Reference Values for chromium [J].
Agostoni, Carlo ;
Canani, Roberto Berni ;
Fairweather-Tait, Susan ;
Heinonen, Marina ;
Korhonen, Hannu ;
La Vieille, Sebastien ;
Marchelli, Rosangela ;
Martin, Ambroise ;
Naska, Androniki ;
Neuhaeuser-Berthold, Monika ;
Nowicka, Grazyna ;
Sanz, Yolanda ;
Siani, Alfonso ;
Sjodin, Anders ;
Stern, Martin ;
Strain, Sean ;
Tetens, Inge ;
Tome, Daniel ;
Turck, Dominique ;
Verhagen, Hans .
EFSA JOURNAL, 2014, 12 (10)
[2]   Effects of fixed orthodontic treatment on nickel and chromium levels in gingival crevicular fluid as a novel systemic biomarker of trace elements: A longitudinal study [J].
Amini, Fariborz ;
Shariati, Mahsa ;
Sobouti, Farhad ;
Rakhshan, Vahid .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 149 (05) :666-672
[3]   Functional Coatings for Orthodontic Archwires-A Review [J].
Bacela, Justyna ;
Labowska, Magdalena Beata ;
Detyna, Jerzy ;
Ziety, Anna ;
Michalak, Izabela .
MATERIALS, 2020, 13 (15)
[4]   SIDE-EFFECTS OF IMMERSION-TYPE CLEANSERS ON METAL COMPONENTS OF DENTURES [J].
BACKENSTOSE, WM ;
WELLS, JG .
JOURNAL OF PROSTHETIC DENTISTRY, 1977, 37 (06) :615-621
[5]   In vivo assessment of DNA damage induced in oral mucosa cells by fixed and removable metal prosthodontic appliances [J].
Baricevic, Marinka ;
Ratkaj, Ivana ;
Mladinic, Marin ;
Zeljezic, Davor ;
Kraljevic, Sandra Pavelic ;
Loncar, Bozana ;
Stipetic, Marinka Mravak .
CLINICAL ORAL INVESTIGATIONS, 2012, 16 (01) :325-331
[6]   EXPERIMENTAL LONG-TERM STUDY OF TITANIUM IONS ELUTED FROM PURE TITANIUM MINIPLATES [J].
BESSHO, K ;
FUJIMURA, K ;
IIZUKA, T .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07) :901-904
[7]  
Bhasin Vinny, 2017, J Contemp Dent Pract, V18, P675
[8]   Trace metal ions release from fixed orthodontic appliances and DNA damage in oral mucosa cells by in vivo studies: A literature review [J].
Downarowicz, Patrycja ;
Mikulewicz, Marcin .
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 26 (07) :1155-1162
[9]  
Ehrlich N., 2019, THESIS RHEINISHCE FR
[10]   In vivo study on metal release from fixed orthodontic appliances and DNA damage in oral mucosa cells [J].
Faccioni, F ;
Franceschetti, P ;
Cerpelloni, M ;
Fracasso, ME .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2003, 124 (06) :687-693