Diagnostic Ability of Macular Nerve Fiber Layer Thickness Using New Segmentation Software in Glaucoma Suspects

被引:27
作者
Martinez-de-la-Casa, Jose M. [1 ,2 ,3 ]
Cifuentes-Canorea, Pilar [1 ,2 ,3 ]
Berrozpe, Clara [1 ,2 ,3 ]
Sastre, Marina [1 ,2 ,3 ]
Polo, Vicente [4 ]
Moreno-Montanes, Javier [5 ]
Garcia-Feijoo, Julian [1 ,2 ,3 ]
机构
[1] Hosp Clin San Carlos, Serv Oftalmol, Madrid 28040, Spain
[2] Univ Complutense Madrid, Fac Med, Dept Oftalmol, Madrid, Spain
[3] Hosp Clinico San Carlos IdISSC, Inst Invest Sanitaria, Madrid, Spain
[4] Hosp Miguel Servet, Serv Oftalmol, Zaragoza, Spain
[5] Univ Navarra Clin, Serv Oftalmol, Pamplona, Spain
关键词
glaucoma; optical coherence tomography; macula; retinal nerve fiber layer; ganglion cell; OPTICAL COHERENCE TOMOGRAPHY; INTRAOCULAR-PRESSURE ELEVATION; REPRODUCIBILITY; HEAD; EYES; OCT;
D O I
10.1167/iovs.14-15501
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the capacity of internal retinal layer thickness measurements made at the macula using new spectral-domain optical coherence tomography (OCT) software to distinguish between healthy subjects and those with suspected glaucoma. The diagnostic performance of such measurements also was compared with that of conventional peripapillary retinal nerve fiber layer (RNFL) thickness measurements. METHODS. The study included 38 subjects with suspected glaucoma and 38 age-matched healthy subjects. In one randomly selected eye of each participant, thickness measurements at the level of the macula were made of the nerve fiber layer (mRNFL), the ganglion cell layer (GCL), and the ganglion cell complex (GCC; GCL + internal plexiform layer) through automated OCT segmentation. Peripapillary RNFL thickness (pRNFL) also was determined using the conventional scan. RESULTS. As the only variable showing intergroup variation, mRNFL in the glaucoma suspects was significantly thinner in the quadrants inner inferior (P = 0.003), inner temporal (P = 0.010), and outer inferior (P = 0.017). The variable best able to discriminate between the two groups was inner inferior mRNFL thickness, as indicated by an area below the receiver operating characteristic (ROC) curve of 0.742. CONCLUSIONS. Macular RNFL thickness measurements showed an improved diagnostic capacity over the other variables examined to distinguish between healthy subjects and glaucoma suspects.
引用
收藏
页码:8343 / 8348
页数:6
相关论文
共 23 条
[1]  
[Anonymous], 2005, PREF PRACT PATT PRIM, P3
[2]   Macular symmetry testing for glaucoma detection [J].
Bagga, H ;
Greenfield, DS ;
Knighton, RW .
JOURNAL OF GLAUCOMA, 2005, 14 (05) :358-363
[3]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[4]   Reproducibility of macular ganglion cell-inner plexiform layer thickness measurement with cirrus HD-OCT in normal, hypertensive and glaucomatous eyes [J].
Francoz, Marlene ;
Fenolland, Jean-Remi ;
Giraud, Jean-Marie ;
El Chehab, Hussam ;
Sendon, Damien ;
May, Franck ;
Renard, Jean-Paul .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (03) :322-328
[5]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[6]   Macular segmentation with optical coherence tomography [J].
Ishikawa, H ;
Stein, DM ;
Wollstein, G ;
Beaton, S ;
Fujimoto, JG ;
Schuman, JS .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) :2012-2017
[7]   Three-Dimensional Imaging of Macular Inner Structures in Glaucoma by Using Spectral-Domain Optical Coherence Tomography [J].
Kotera, Yuriko ;
Hangai, Masanori ;
Hirose, Fumitaka ;
Mori, Satoshi ;
Yoshimura, Nagahisa .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) :1412-1421
[8]   Analysis of macular volume in normal and glaucomatous eyes using optical coherence tomography [J].
Lederer, DE ;
Schuman, JS ;
Hertzmark, E ;
Heltzer, J ;
Velazques, LJ ;
Fujimoto, JG ;
Mattox, C .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (06) :838-843
[9]   Optic nerve dynein motor protein distribution changes with intraocular pressure elevation in a rat model of glaucoma [J].
Martin, Keith R. G. ;
Quigley, Harry A. ;
Valenta, Danielle ;
Kielczewski, Jennifer ;
Pease, Mary Ellen .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (02) :255-262
[10]   Reproducibility of evaluation of optic disc change for glaucoma with stereo optic disc photographs [J].
Miglior, S ;
Zeyen, T ;
Pfeiffer, N ;
Cunha-Vaz, J ;
Linsen, MC ;
Pellicci, L ;
Janssens, A ;
van der Veken, A ;
Nerinckx, F ;
Boeyden, V ;
Czupper, M ;
Wendrix, G ;
Detry-Morel, M ;
Kestelyn, P ;
Van den Abeele, K ;
Jacobs, K ;
Decock, C ;
Goethals, M ;
Pourjavan, S ;
Maris, K ;
Deghislage, C ;
Kersten, I ;
Vogel, A ;
Herkel, U ;
Schwenn, O ;
Maser-Wahle, M ;
Funk, J ;
Schmidt, B ;
Akbariyeh, N ;
Burk, R ;
Thomsen, A ;
Grehn, F ;
Marquardt, D ;
Orzalesi, N ;
Rossetti, L ;
Ferrante, M ;
Mandelli, L ;
Marini, S ;
Bertoni, G ;
Blini, M ;
De Molfetta, M ;
Bonomi, L ;
Morbio, R ;
Marraffa, M ;
Maraini, G ;
Gandolfi, S ;
Williams, S ;
Cimino, L ;
Dondi, P ;
Lumbroso, B .
OPHTHALMOLOGY, 2003, 110 (02) :340-344