Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT

被引:75
作者
Taguchi, K [1 ]
机构
[1] Toshiba Co Ltd, Med Syst Co, Med Syst Res & Dev Ctr, CT & Nucl Med Dev Dept, Otawara, Tochigi 3248550, Japan
关键词
computed tomography; dynamic imaging; volumetric imaging; four-dimensional CT;
D O I
10.1118/1.1561286
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The four-dimensional computed tomography ("4D-CT") with area detector has been developed for dynamic volumetric imaging with large longitudinal coverage. In this paper one of the key technologies for 4D-CT development is discussed: Image reconstruction algorithm with high temporal resolution. All of the cone-beam algorithms investigated previously assume that the object is stationary. In this paper a new class of cone-beam problem is addressed: a dynamic volumetric (4-D) imaging. A continuously rotating circular (stationary couch) scanning is employed, and then, a generalized version of the well-known Feldkamp algorithm with the following three steps is performed: (1) applying a weighting function (along the time axis) to projection data, (2) filtering the weighted data along the detector row direction, (3) cone-beam backprojecting of the filtered data along the corresponding x-ray path. The weighting function controls the time center, the temporal resolution, and the image quality. Four weighting functions developed for fan-beam reconstruction were applied to the first step: (a) a constant weight fixed at 0.5 (FS-FDK), (b) feathering both edges of the (time) window (OS-FDK), (c) Parker's weight for a half-scan (HF-FDK), and (d) an extended Parker's weight, which allows us to use a larger range of projection data up to one rotation (NHS-FDK). We evaluated them in terms of temporal resolution, image noise, and image quality. Also, the cause of them artifact has been investigated. The temporal resolution of NHF-FDK equals that of HS-FDK, which is half of the one rotation period. For the moving object, NHS-FDK offers the best image quality. The images with FS-FDK are degraded by streak artifacts; HS-FDK provides poor image quality with good temporal resolution; and images by OS-FDK are blurred due to insufficient temporal resolution. The cause of the artifact was found as an inconsistency of projection data due to object motion (in FS-FDK) and lost 3-D-Radon data caused by applying Parker's weight (in HS-FDK). A hand toy was employed for the preliminary evaluation of dynamic volumetric imaging with the real 256-slice scanner. In an overall evaluation, NHS-FDK provides the stable and the sufficient image quality both with moving and stationary objects. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:640 / 650
页数:11
相关论文
共 41 条
[1]  
ANNO H, 1989, JPN J CLIN RADIOL, V34, P27
[2]  
ANNO H, 1990, MED REV, V31, P15
[3]   High temporal resolution volume heart imaging with multirow computed tomography [J].
Bruder, H ;
Schaller, S ;
Ohnesorge, B ;
Mertelmeier, T .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :420-432
[4]   COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[5]   A solution to the long-object problem in helical cone-beam tomography [J].
Defrise, M ;
Noo, F ;
Kudo, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) :623-643
[6]   A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION [J].
DEFRISE, M ;
CLACK, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) :186-195
[7]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[8]   DYNAMIC HEPATIC CT [J].
FOLEY, WD .
RADIOLOGY, 1989, 170 (03) :617-622
[9]   Practical x-ray scatter measurements for volume CT detector design [J].
Fox, TR ;
Nisius, DT ;
Aradate, H ;
Saito, Y .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :808-814
[10]  
GRANGEAT P, 1990, LECT NOTES MATH, V149